The largest database of trusted experimental protocols

Signa excite hdxt mr scanner

Manufactured by GE Healthcare
Sourced in United Kingdom

The Signa Excite HDxt MR Scanner is a magnetic resonance imaging (MRI) system developed by GE Healthcare. It is designed to capture high-quality images of the body's internal structures. The Signa Excite HDxt MR Scanner utilizes advanced imaging technology to provide detailed visualization for medical professionals.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using signa excite hdxt mr scanner

1

Multimodal Neuroimaging Data Acquisition

Check if the same lab product or an alternative is used in the 5 most similar protocols
Neuroimaging data acquisitions were carried out on a 1.5 T GE Signa Excite HDxt MR Scanner (GE Healthcare, Chalfont St. Giles, UK) within one month of the behavioural testing. Three-dimensional spoiled gradient echo images (FSPGR: echo time [TE]: 4.1 ms; repetition time [TR]: 10.276 ms; matrix: 256x256; field of view [FOV]: 25cmx25cm; flip angle: 15°; in-plane resolution: 1mmx1mm; slice thickness: 1mm) and 60-direction diffusion-weighted images with 6 non-diffusion-weighted reference volumes (TE: 93.6 ms; TR: 16.000 ms; matrix: 96x96; FOV: 23cmx23cm; flip angle: 90°; in-plane resolution: 2.4mmx2.4 mm; slice thickness: 2.4mm; b: 1000 s/mm2; number of excitations [NEX]: 2; array spatial sensitivity encoding technique [ASSET]) were acquired.
+ Open protocol
+ Expand
2

Multimodal MRI Acquisition of Interictal Migraine

Check if the same lab product or an alternative is used in the 5 most similar protocols
All MRI acquisitions were in the interictal period, minimum 1 week after the last headache attack. MRI acquisitions were carried out on a 1.5 T GE Signa Excite HDxt MR Scanner (GE Healthcare, Chalfont St. Giles, United Kingdom). Three dimensional spoiled gradient echo images [FSPGR: echo time (TE): 4.1 ms; repetition time (TR): 10.276 ms; matrix: 256 256; field of view (FOV): 25 cm 25 cm; flip angel: 15°; in-plane resolution: 1 mm 1 mm; slice thickness: 1 mm] and 60 directions diffusion-weighted images with 6 non-diffusion-weighted reference volume [TE: 93.8 ms; TR: 16.000 ms; matrix: 96 96; FOV: 23 cm 23 cm; flip angle: 90°; in-plane resolution: 2.4 mm 2.4 mm; slice thickness: 2.4 mm; b: 1000 s/mm2; number of excitations (NEX): 2; array spatial sensitivity encoding technique (ASSET) factor = 2] were acquired for all subjects.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.