The largest database of trusted experimental protocols

3 protocols using glycerol dimethacrylate

1

Synthesis and Characterization of Dental Monomers

Check if the same lab product or an alternative is used in the 5 most similar protocols
BisGMA (Polysciences, Warrington, PA) and HEMA (Acros Organics, NJ) were used as received without further purification as monomers in dentin adhesives. BMPB was synthesized as reported previously in our laboratory.30 (link) 4-((1,3-Bis(methacryloyloxy)propan-2-yl)oxy)– 2-methylene-4-oxo-butanoic acid (BMPMOB) was synthesized in our laboratory and used as a comonomer (Figure 1). Itaconic anhydride (IAA) and glycerol dimethacrylate (GDMA) were obtained from Sigma-Aldrich (St. Louis, MO). Camphoroquinone (CQ), ethyl-4-(dimethylamino) benzoate (EDMAB), and diphenyliodonium hexafluorophosphate (DPIHP) were obtained from Sigma-Aldrich. All other chemicals were reagent grade and used without further purification.
+ Open protocol
+ Expand
2

Adhesive Resin Formulation and Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
2,2-Bis[4-(2-hydroxy-3-methacryloxypropoxy) phenyl]-propane (BisGMA, Polysciences, Warrington, PA) and 2-hydroxyethylmethacrylate (HEMA, Acros Organics, NJ) were used as received without further purification, as monomers in dentin adhesives. Two siloxane methacrylate monomers (SM1 and SM2) were synthesized in our lab. The control adhesive resin consisted of HEMA and BisGMA with a mass ratio of 45/55. This control was used to compare with the experimental adhesive resins with HEMA / BisGMA / SM = 45/55-x/x (w/w) ratio. The control and experimental adhesives were also formulated with 12 wt % water to simulate bonding in the mouth. The concentration of water was based on the total final weight of the adhesive resin. Camphorquinone (CQ, 0.5 wt %), ethyl-4-(dimethylamino) benzoate (EDMAB, 0.5 wt %) and diphenyliodonium hexafluorophosphate (DPIHP,1.0 wt %) were obtained from Aldrich (Milwaukee, WI, USA) and used as a three-component-photoinitiator system without further purification. 2,4,6,8-Tetramethyl-2,4,6,8-tetrakis (propyl glycidyl ether) cyclotetrasiloxane (TPGTS), Glycerol dimethacrylate (GDMA, assay 85%, mixture of isomers), ethyl acetate, boron trifluoride diethyl etherate (BF3O(C2H5)2), anhydrous magnesium sulfate (MgSO4), and all other chemicals were purchased from Sigma-Aldrich at reagent grade and used without further purification.
+ Open protocol
+ Expand
3

Patulin Analysis in Apple Juice

Check if the same lab product or an alternative is used in the 5 most similar protocols
2,2-Dimethoxy-2-phenylacetophenone (DMPA), all functional monomers (acrylamide, AM; acrylonitrile, AN; 4-acryloylmorpholine, AMO; allylamine, ALA; N,N-diethylaminoethylmethacrylate, DEAEM; N,N-dimethylacrylamide, DMAM; N,N-dimethylaminoethylmethacrylate, DMAEM; ethylenglycol methacrylate phosphate, EGMP; 2-hydroxyethylmethacrylate, HEMA; methacrylic acid, MAA; methylacrylate, MA; monomethoxypolyethylenglycol 400 methacrylate, PEGMA; styrene, STY; 1-vinylimidazole, VIM; 4-vinylpyridine, 4VP; N-vinylpyrrolidone, NVP), cross-linkers (ethylene dimethacrylate, EDMA; glycerol dimethacrylate, GDMA; pentaerithrytole tetraacrylate, PETRA; trimethylolpropane trimethacrylate, TRIM) were from Sigma (Milan, Italy). Polymerization inhibitors eventually present in monomer solutions were removed by clean-up on activated alumina columns. Acetic acid, all organic solvents and all other chemicals were from VWR International (Milano, Italy). All the solvents were of HPLC grade, whereas all chemicals were of analytical grade. Patulin was from Fermentek (Jerusalem, Israel).
Patulin stock solutions were prepared by dissolving 10.0 mg of solid mycotoxin in 10 mL of acetonitrile and stored in the dark at −20 °C until use. Apple juice certified as free from patulin was a gift from Generon s.r.l. (Modena, Italy).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!