The largest database of trusted experimental protocols

2 protocols using sc 166412

1

Colocalization of β5i and RIG-I

Check if the same lab product or an alternative is used in the 5 most similar protocols
To explore the colocalisation of β5i and RIG-I, double-label immunostaining was performed. After blocking with 5% bovine serum albumin in PBST at room temperature for 1 hour, the samples were treated with mouse anti-RIG-I monoclonal antibody (1:50, sc-376845, Santa Cruz Biotechnology) and rabbit anti-β5i monoclonal antibody (1:2000, ab180606, Abcam) overnight at 4°C, followed by three washes with PBS (10 min each wash). Next, the samples were treated with Alexa Fluor 594-conjugated goat anti-mouse IgG (1:200, 8890, Cell Signaling Technology) and Alexa Fluor 488-conjugated goat anti-rabbit IgG (1:200, 4412, Cell Signaling Technology), which were used as the secondary antibodies, in a dark chamber for 1 hour, followed by three washes with PBST. After counterstaining with DAPI (Beyotime, Shanghai, China), the slides were mounted with coverslips. To clarify whether β5i is expressed in regenerative myocytes, we performed double-label immunostaining using rabbit anti-β5i monoclonal antibody (1:2000, ab180606, Abcam) and mouse anti-NCAM1 monoclonal antibody (1:500, ab6123, Abcam), following the same procedure mentioned above. In addition, double-label immunofluorescence staining using rabbit anti-β5i monoclonal antibody and mouse anti-MxA monoclonal antibody (1:100, sc-166412, Santa Cruz) was performed following the above procedure.
+ Open protocol
+ Expand
2

Western Blot Analysis of Immune Signaling

Check if the same lab product or an alternative is used in the 5 most similar protocols
The total proteins were extracted and separated by 10% or 15% SDS-PAGE and were transferred to polyvinylidene difluoride membranes (Millipore, Bedford, Massachusetts, USA) using a semi-dry Gel Transfer Device (Bio-Rad, Hercules, California, USA). The membranes were blocked using 5% non-fat milk and probed with primary antibodies and HRP-conjugated secondary antibodies. Antigen-antibody complexes were visualised using a chemiluminescent ECL detection system and analysed using a ChemDoc XRS+image analyser. GAPDH or β-actin was used as an internal control. The antibodies used included anti-β5i (1:5000, ab180606, Abcam), anti-RIG-I (1:2000,3743, Cell Signaling Technology), anti-Phospho-NF-κB p65 (1:1000, 3033, Cell Signaling Technology), anti-Phospho-IRF3 (1:500, ab76493, Abcam), anti- IFNβ (1:500, ab275880, Abcam), anti- MxA (1:500, sc-166412, Santa Cruz), anti-MuRF1 (1:2000, ab172479, Abcam), anti-β-actin (1:5000, YM3028, Immunoway) and anti-GAPDH (1:10000, YM3029, Immunoway). The selective β5i inhibitor PR-957 was purchased from Selleck Chemicals (Houston, Texas, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!