Lambda 1050

Manufactured by Thorlabs

The Lambda 1050+ is a UV-Vis-NIR spectrophotometer designed for high-performance applications. It features a double-beam optical system and a wide wavelength range of 175 to 3300 nm. The instrument is capable of various measurements, including transmittance, reflectance, and absorbance.

Automatically generated - may contain errors

2 protocols using lambda 1050

1

Characterization of Liquid Crystalline Polymer Films

Check if the same lab product or an alternative is used in the 5 most similar protocols
Liquid crystalline phase transition temperature was measured with DSC curves using a differential scanning calorimeter (DSC 2500, TA Instruments) with a temperature ramp rate of 10 °C min−1. Cholesteric textures of LC samples were characterized with Zeiss AXIO polarized optical microscope. Reflection spectra were measured with PerkinElmer Lambda 1050+ photospectrometer and Thorlabs CCS200/M Compact Spectrometer. Keyence laser scanning microscope VK-X250 was used to measure the sample thickness in dry/humid states. The mechanical properties of samples were measured with a tensile machine Instron 5942 using a 10 N load cell with a displacement rate of 0.05 mm s−1. In the tensile test, CLCN films in the size of 10 mm × 20 mm were used. The thickness of films at different states was measured for the calculation of corresponding Young's moduli.
+ Open protocol
+ Expand
2

Characterization of Liquid Crystalline Polymer Films

Check if the same lab product or an alternative is used in the 5 most similar protocols
Liquid crystalline phase transition temperature was measured with DSC curves using a differential scanning calorimeter (DSC 2500, TA Instruments) with a temperature ramp rate of 10 °C min−1. Cholesteric textures of LC samples were characterized with Zeiss AXIO polarized optical microscope. Reflection spectra were measured with PerkinElmer Lambda 1050+ photospectrometer and Thorlabs CCS200/M Compact Spectrometer. Keyence laser scanning microscope VK-X250 was used to measure the sample thickness in dry/humid states. The mechanical properties of samples were measured with a tensile machine Instron 5942 using a 10 N load cell with a displacement rate of 0.05 mm s−1. In the tensile test, CLCN films in the size of 10 mm × 20 mm were used. The thickness of films at different states was measured for the calculation of corresponding Young's moduli.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!