Ingenia wide bore dstream 3t mri scanner

Manufactured by Philips
Sourced in Netherlands

The Ingenia wide-bore dStream 3T MRI scanner is a magnetic resonance imaging (MRI) system manufactured by Philips. It operates at a magnetic field strength of 3 Tesla, which allows for high-quality imaging. The wide-bore design provides a larger opening for patient comfort and access.

Automatically generated - may contain errors

4 protocols using ingenia wide bore dstream 3t mri scanner

1

Resting-state fMRI Acquisition Protocol Using 3T MRI Scanner

Check if the same lab product or an alternative is used in the 5 most similar protocols
MRI scans were acquired using the Philips Medical Systems (Best, Netherlands) Ingenia wide-bore dStream 3T MRI scanner, with a 32-channel receive head coil. Single shot gradient-echo echoplanar imaging (EPI) was used for acquiring fMRI data. The fMRI acquisition parameters were: SENSE in-plane acceleration factor 1.5, multiband factor 3, repetition time 1625 ms, echo time 30 ms, flip angle 52°, field of view 240 mm (anterior-to-posterior) × 240 mm (left-to-right) × 125.70 mm (foot-to-head), in-plane resolution 2.5 mm × 2.5 mm, 45 axial slices, slice thickness 2.5 mm, interslice gap 0.30 mm, 420 repetitions per run after 12 dummy acquisitions, and total duration 11 minutes 22 seconds. Subjects completed the resting state fMRI scan with eyes open while looking at a black fixation cross on a white screen. Greater detail regarding MRI acquisition parameters is available in Supplementary File.
+ Open protocol
+ Expand
2

Resting-State fMRI Protocol for 3T MRI

Check if the same lab product or an alternative is used in the 5 most similar protocols
MRI scans were acquired using a Philips Medical Systems (Best, Netherlands) Ingenia wide-bore dStream 3 T MRI scanner, with a 32-channel receive head coil. A spin-echo echo planar pulse sequence was used with: parallel imaging acceleration-factor 2.0, repetition-time 2500 ms, echo-time 75 ms, flip-angle 90 degrees, field-of-view 240 mm (anterior to posterior) × 240 mm (left to right) × 123.75 mm (foot to head), in-plane resolution 3.75 mm × 3.75 mm, 25 axial slices, slice-thickness 3.75 mm, interslice-gap 1.25 mm, 112 repetitions per run after 10 dummy acquisitions. Total duration per run was approximately 5 min.
+ Open protocol
+ Expand
3

Resting-state fMRI Acquisition Protocol Using 3T MRI Scanner

Check if the same lab product or an alternative is used in the 5 most similar protocols
MRI scans were acquired using the Philips Medical Systems (Best, Netherlands) Ingenia wide-bore dStream 3T MRI scanner, with a 32-channel receive head coil. Single shot gradient-echo echoplanar imaging (EPI) was used for acquiring fMRI data. The fMRI acquisition parameters were: SENSE in-plane acceleration factor 1.5, multiband factor 3, repetition time 1625 ms, echo time 30 ms, flip angle 52°, field of view 240 mm (anterior-to-posterior) × 240 mm (left-to-right) × 125.70 mm (foot-to-head), in-plane resolution 2.5 mm × 2.5 mm, 45 axial slices, slice thickness 2.5 mm, interslice gap 0.30 mm, 420 repetitions per run after 12 dummy acquisitions, and total duration 11 minutes 22 seconds. Subjects completed the resting state fMRI scan with eyes open while looking at a black fixation cross on a white screen. Greater detail regarding MRI acquisition parameters is available in Supplementary File.
+ Open protocol
+ Expand
4

Functional MRI Acquisition Protocol for fMRI Experiments

Check if the same lab product or an alternative is used in the 5 most similar protocols
MRI scans were acquired using the Philips Medical Systems (Best, Netherlands) Ingenia wide-bore dStream 3T MRI scanner, with 32-channel receive head coil. Single shot spin echo echoplanar imaging (EPI) was used for acquiring fMRI data. The fMRI acquisition parameters were: parallel imaging SENSE acceleration factor 2.0, repetition time 2500 ms, echo time 75 ms, flip angle 90 degrees, field of view 240 mm (anterior-to-posterior) × 240 mm (left-to-right) × 123.75 mm (foot-to-head), in-plane resolution 3.75 mm × 3.75 mm, 25 axial slices, slice thickness 3.75 mm, interslice gap 1.25 mm, 112 repetitions per run after 10 dummy acquisitions, and total duration approximately 5 min.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!