The largest database of trusted experimental protocols

5 protocols using cd16 pe

1

Flow Cytometry Analysis of Surface Markers

Check if the same lab product or an alternative is used in the 5 most similar protocols
Flow cytometry was used for the analysis of surface marker or transgene expression. The following antibodies were used: CD3-APC (OKT3, BioLegend, San Diego, CA, USA), CD16-PE (REA423, Miltenyi), CD56-APC (AF12-7H3, BioLegend; HCD56, Miltenyi Biotec), CD56-FITC (REA196 Miltenyi), CD56-PE (B159, Becton Dickinson, BD, Heidelberg, Germany), Ganglidiomab-PE (Gangliomab-phycoerythrin (PE) monoclonal antibody was kindly provided by H. Lode and N. Siebert (46 (link)) and PE-conjugated), IgG, F(ab′)2 (Biotin-SP-conjugated, Jackson ImmunoResearch, West Grove, PA, USA), Ganglioside GD2-APC (14G2a, BioLegend), Ganglioside GD2-PE (14G2a, BioLegend), and Annexin V-PE (BD Biosciences, Franklin Lakes, USA) and the secondary antibodies Streptavidin-APC (BioLegend) and Streptavidin-PE (eBioscience, San Diego, CA, USA). For staining of the degranulation marker CD107a, cocultures were incubated with CD107a-APC (Miltenyi) for 1 h at 37°C and 5% CO2 with shaking. Afterward, Brefeldin A (1:1,000; BioLegend) and Monensin (1:1,000; BioLegend) were added for an additional incubation for 4 h at 37°C and 5% CO2 with shaking. Stained cells were measured via FACSCalibur cytometer (Becton Dickinson, BD) or CytoFLEX (Beckman Coulter) and analyzed via FlowJo software (Tree Star Inc., Ashland, OR, USA).
+ Open protocol
+ Expand
2

Flow Cytometry Immunophenotyping Panel

Check if the same lab product or an alternative is used in the 5 most similar protocols
MACSQuant Analyzer, MACSQuant Analyzer VYB (Miltenyi Biotec), or FACSCanto, LSRII (Becton Dickinson, NJ) was used to analyze cell populations by flow cytometry. The following antibody and protein conjugates were used: CD3-PE, CD3-APC-Vio770, CD4-APC, CD4-VioGreen, CD8-APC-Vio770, CD8-VioGreen, CD14-APC, CD16-PE, CD19-APC, CD20-PerCP-Vio770, CD20-PE-Vio770, CD34-APC, CD34-PE, CD45-VioBlue, CD45-VioGreen, CD45RO-PE-Vio770, CD56-PE, CD62L-VioBlue, CD95-APC, CD45-VioBlue (mouse) (all from Miltenyi Biotec); ErbB2-Fc fusion protein (R&D Systems), anti-human-IgG (Fc gamma-specific) PE (eBioscience). 7AAD staining was used for dead cell exclusion and Violet Cell Trace (Thermo Fisher) for SupT1 cell tracking.
+ Open protocol
+ Expand
3

Immunophenotyping of PBMC and T-cells

Check if the same lab product or an alternative is used in the 5 most similar protocols
Staining of cell surface markers on PBMC and T-cells was performed with CD3-APC/Vio770, CD4-Vioblue, CD8-Viogreen, CD19-FITC, CD56-PE/Vio770, CD16-PE, CD62L-Vioblue, CD45RA-PE, CD45RO-APC, and CCR7-FITC (Miltenyi, San Diego, CA; BD, Franklin Lakes, NJ). All samples were acquired on a MACSQuant Cytometry (Miltenyi) and the data analyzed with Flow Jo (Treestar, Ashland, OR).
+ Open protocol
+ Expand
4

Comprehensive CBMC and T Cell Immunophenotyping

Check if the same lab product or an alternative is used in the 5 most similar protocols
Staining of cell surface markers on CBMCs and T cells was performed with CD3-APC/Vio770, CD4-Vioblue, CD8-Viogreen, CD19-FITC, CD56-PE/Vio770, CD16-PE, CD62L-Vioblue, CD45RA-PE, CD45RO-APC, and CCR7-FITC (Miltenyi Biotec and BD Biosciences). 50,000 events per sample were acquired on a MACSQuant cytometer (Miltenyi), and the data were analyzed with Flow Jo (Tree Star).
+ Open protocol
+ Expand
5

Immunophenotyping of Whole Blood in GCA

Check if the same lab product or an alternative is used in the 5 most similar protocols
Venous blood was drawn from GCA patients into heparin-containing tubes. Whole blood immunophenotyping was performed using 7-Color Immunophenotyping kit with the following antibodies (Miltenyi Biotec, catalog #130-098-456): CD14-FITC (clone Tük4), CD56-PE (clone REA196), CD16-PE (clone REA423), CD4-PerCP (clone VIT4), CD19-PE-Vio® 770 (clone LT19), CD3-APC (clone BW264/56), CD8-APC-Vio 770 (clone BW135/80), CD45-VioBlue® (clone 5B1). Briefly, 100 μl of whole blood was incubated with 10 μl immunophenotyping reagent for 10 min in the dark, at 4°C. After incubation, whole blood was lysed using Red Blood Lysing Solution (Miltenyi Biotec, catalog #130-098-456). Neutrophil phenotyping was performed in 50 μl of whole blood, incubated for 30 min at 4°C in the dark, with the following antibodies (eBioscience): CD16-PE (clone eBioCB16; catalog #50-112-4738), CD62L-PE-Cy5 (clone DREG56; catalog #50-140-71) and CD11b-APC (clone ICRF44; catalog #17-0118-42). After incubation, samples were lysed, using Whole Blood Lysing Reagent Kit (Beckman Coulter; catalog #6602764). All samples were analyzed using flow cytometer MACSQuant Analyzer 10 (Miltenyi Biotec). Analysis of flow cytometry data was performed using MACSQuantify (Analysis Software version 2.8, Miltenyi Biotec) and FlowLogic (Flow Cytometry Analysis Package, version 7.00.0a, Invasion Software Technologies Pvt Ltd).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!