The largest database of trusted experimental protocols

Sodium citrate based er1 buffer

Manufactured by Leica Biosystems

Sodium citrate-based ER1 buffer is a laboratory reagent used for antigen retrieval in immunohistochemistry (IHC) and immunofluorescence (IF) procedures. It is designed to help unmask target antigens in fixed tissue samples, facilitating the binding of specific antibodies during the staining process.

Automatically generated - may contain errors

2 protocols using sodium citrate based er1 buffer

1

Histological Analysis of Hamster Lung Tissue

Check if the same lab product or an alternative is used in the 5 most similar protocols
Formalin-fixed and paraffin-embedded tissue sections were stained with hematoxylin and eosin (H&E) or anti-Iba-1 antibody (Wako; 019–19,741 Richmond, VA; at a dilution of 1:2000). Morphometric analyses were performed on affected lung tissues using Image J software (NIH, USA) [22 (link)]. A minimum of three fields of view were obtained from each animal (n = 6 animals; 3 male and 3 female hamsters). Heat-induced epitope retrieval was conducted by heating slides to 95 °C for 20 min in sodium citrate–based ER1 buffer (Leica Biosystems, Richmond, IL) before immunostaining. Immunostaining was performed using the Bond RX automated system (Leica Biosystems, Richmond, IL). Positive immunostaining was visualized using diaminobenzidine tetrahydrochloride (DAB) and slides were counterstained with hematoxylin.
+ Open protocol
+ Expand
2

TREM2 and IBA1 Expression in SIV-Infected Brain

Check if the same lab product or an alternative is used in the 5 most similar protocols
TREM2 ISH was combined with IBA1 immunostaining performed on frontal cortex sections from an SIV infected animal. TREM2 ISH was performed as described above. The first heat-induced epitope retrieval was conducted by heating slides to 95°C in EDTA-based ER2 buffer for 15 minutes (Leica Biosystems, Richmond, IL). Slides were then stained with anti-IBA1 antibody (cat. 01919741, Wako, Richmond, VA) at a dilution of 1:500. IHC was performed using the Bond RX automated system (Leica Biosystems, Richmond, IL). A second heat-induced epitope retrieval was conducted by heating slides to 95°C for 20 minutes in sodium citrate-based ER1 buffer (Leica Biosystems, Richmond, IL). Positive immunostaining was visualized using DAB, and slides were counterstained with hematoxylin.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!