The largest database of trusted experimental protocols

Mnova software version 14

Manufactured by Mestrelab Research
Sourced in Spain

Mnova software version 14.2.1 is a data analysis and processing tool designed for Nuclear Magnetic Resonance (NMR) spectroscopic data. The software provides a suite of functionalities for visualizing, processing, and analyzing NMR spectra.

Automatically generated - may contain errors

2 protocols using mnova software version 14

1

LC-MS Analysis of Bioactive Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
The fraction that exhibited the greatest inhibition of AChE activity was further explored for bioactive compounds through LC-MS analysis, performed at the Sophisticated Analytical Instrument Facility, CSIR-Central Drug Research Institute, Lucknow. The LC-MS and MS/MS simulations were carried out using a Waters Alliance E2695/HPLC-TQD mass spectrometer with a mass range of 100–2000 Da. Separation was achieved on an Agilent Poroshell 120 EC C-18 column (150 mm × 4.6 mm, 2.7 μm). Two mobile phases were used: A-0.1% formic acid in water and B-90% of acetonitrile in water, at a flow rate of 1.500 mL/min. The gradient started with A-5% and B-95%, a linear increase in A% and decrease in B% after 6 min at A-30% and B-70%; during 12–16 min, A-60% B-40%; 20 min, A-80% and B-20%; and 26–30, min A-5% and B-95%. The chromatograms were compared to the available literature to identify the peaks, and then, the output file was subjected to analyze the peaks via Mnova software version 14.2.1 offered by Mestrelab Research, chemistry software solutions.
+ Open protocol
+ Expand
2

Spectroscopic Characterization of Drug Formulations

Check if the same lab product or an alternative is used in the 5 most similar protocols
The 1H NMR spectra were acquired at 25 °C utilizing D2O as the solvent and trimethyl silane (TMS) as the internal standard on a Bruker AV 500 MHz (Bruker BioSpin, Zurich, Switzerland) instrument. Mnova software version 14.2.1 (Mestrelab Research, Santiago de Compostela, Spain) was used to process the data. Spectrum Two FTIR spectrometer (Perkin Elmer, Buckinghamshire, UK) with diamond attenuated total reflectance (ATR) crystal (with 16 scans) was used to assess drug-formulation interactions. Spectra were collected from 400 to 4000 cm−1, including both loaded and unloaded formulations, as well as pure forms of the ingredients [62 (link)].
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!