The largest database of trusted experimental protocols

Mak006 1kt

Manufactured by Merck Group
Sourced in United States

MAK006-1KT is a laboratory equipment product from Merck Group. It is used for a specific analytical function, but without further details on its intended use or interpretation of its capabilities.

Automatically generated - may contain errors

4 protocols using mak006 1kt

1

Spectrophotometric Determination of Serum Urea and Creatinine

Check if the same lab product or an alternative is used in the 5 most similar protocols
Serum urea and creatinine were measured with spectrophotometric reagents commercially available (MAK006-1KT, MAK080-1KT, Sigma, Saint-Louis, MO, USA) and the absorbance was measured using Multiskan FC Microplate Photometer (Thermo Fisher Scientific, Waltham, MA, USA). Blood urea nitrogen (BUN) was calculated using the following formula: urea (mg/dL) × 0.467 = BUN (mg/dL).
+ Open protocol
+ Expand
2

Hepatocyte Co-Culture Ammonia Metabolism

Check if the same lab product or an alternative is used in the 5 most similar protocols
Sixteen to twenty hours after seeding hepatocytes, culture media was removed from bioreactors and 2 L of co-culture media supplemented with 0.8 mM ammonium chloride. Bioreactor media perfusion was resumed, and media samples were collected in duplicate at t = 0 h, 1 h, 2 h, 7 h, and 23 h. Media ammonia levels were quantified on a CEDEX BioHT, and duplicate frozen samples were assayed in parallel to measure urea produced over time (Sigma, MAK0061KT).
+ Open protocol
+ Expand
3

Serum Biomarkers for Kidney Injury

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood biochemical analysis was performed according to previous investigations. The blood samples were extracted 24 h following sham or CLP operation and centrifuged at 1400 x g to prepare serum at 4°C for 10 min. SCr levels were evaluated by a creatinine enzymatic assay kit (MAK080-1KT, Sigma-Aldrich, Merck KGaA) and measured at 570 nm. BUN was detected with an enzymatic assay kit (MAK006-1KT, Sigma-Aldrich, Merck KGaA) and measured at 570 nm. The expression levels of NGAL (ab119602, Abcam) and KIM-1(ab119597, Abcam) were measured using corresponding kits and measured at 450 nm. All measurements were conducted with a multiscan spectrum spectrophotometer (Thermo Fisher Scientific Inc.)
+ Open protocol
+ Expand
4

Serum Biomarker Analysis in Tumor-Bearing Mice

Check if the same lab product or an alternative is used in the 5 most similar protocols
Mouse blood was collected without using an anticoagulant and was allowed to clot for 2 h at room temperature. The serum was then separated by centrifugation at 2000 g for 15 min. The levels of alanine aminotransferase (ALT), aspartate aminotransferase (AST), and blood urea nitrogen (BUN) in serum from tumor-bearing mice were analyzed using the commercially available kits (Cat# MAK052-1KT, MAK055-1KT and MAK006-1KT, Sigma-Aldrich, St. Louis, MO, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists