The largest database of trusted experimental protocols

2 protocols using fluoxetine

1

Radioligand Binding Assay Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols

Buprenorphine, citalopram, codeine, dextromethorphan, dihydrocodeine, fentanyl, heroin (diacetylmorphine, diamorphine), 6‐acetylmorphine (6‐mono‐acetylmorphine), hydrocodone, hydromorphone, mazindol, MDMA, methadone, morphine, oxycodone, oxymorphone, pethidine (meperidine), tramadol, O‐desmethyl‐cistramadol, tapentadol, venlafaxine and fluoxetine were purchased from Lipomed (Arlesheim, Switzerland). Mianserin, nisoxetine, pargyline, pindolol and spiperone were supplied by Sigma‐Aldrich (Buchs, Switzerland). D(S)‐methadone and l(R)‐methadone were obtained from Alsachim (Illkirch Graffenstaden, France). The HPLC purity of all of the substances was >98%. [3H]‐8‐OH‐DPAT, [3H]‐ketanserin and [3H]‐mesulergine were supplied by Perkin‐Elmer.
+ Open protocol
+ Expand
2

Simultaneous LCMS Analysis of Psychoactive Drugs

Check if the same lab product or an alternative is used in the 5 most similar protocols
Standard solutions of the analytes alprazolam (ALP), citalopram (CIT), diazepam (DIAZ), doxepin (DOX), flunitrazepam (FLUN), fluoxetine (FLUOX), carbamazepine (CARB), cocaethylene (COCET), cocaine (COC), norcocaine (NORCOC), nordiazepam (NORDIAZ), nortriptyline (NORTR), oxazepam (OXA), temazepam (TEM), and venlafaxine (VEN) were purchased from Lipomed AG (Arlesheim, Switzerland). Deuterated derivatives of the analytes alprazolam-d5, diazepam-d5, flunitrazepam-d3, fluoxetine-d6, carbamazepine-d10, nordiazepam-d5, oxazepam-d5, and temazepam-d5, used as internal standards, were also purchased from Lipomed AG (Arlesheim, Switzerland). The selected number of 15 analytes, including six metabolites, was considered sufficient given that it was a preliminary study, and increasing the complexity of the method could potentially cause selectivity problems.
High-purity LC-MS chromatographic solvents acetonitrile, methanol, isopropyl alcohol, and sodium hydroxide obtained from Fluka Analytical (Seelze, Germany) were used in the experiment. Analytical-grade solvents acetonitrile, methanol, isopropyl alcohol, sodium hydroxide, and ammonium formate from Sigma-Aldrich (St. Louis, MO, USA) and formic acid obtained from Merck (Darmstadt, Germany) were also used. Deionized ultrapure water (18.2 M Ω · cm, TOC < 5 ppb) was obtained with the Milli-Q Plus system (Millipore, Bedford, MA, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!