The largest database of trusted experimental protocols

Advia centaur analyser

Manufactured by Bayer
Sourced in United Kingdom

The ADVIA Centaur analyzer is a fully automated, random-access immunoassay system designed for clinical laboratory use. It is capable of performing a wide range of immunoassay tests, including those for hormones, infectious diseases, and other analytes. The system features advanced technology for precise and reliable results.

Automatically generated - may contain errors

2 protocols using advia centaur analyser

1

Anthropometry and Metabolic Assessments

Check if the same lab product or an alternative is used in the 5 most similar protocols
Anthropometry was evaluated and laboratory tests were performed in all the participants according to established protocols at OPBG. Participants were asked to refrain from intensive physical activity in the 3 days prior to any study. Weight and height were measured using standard procedure. Up to 3 blood pressure measurements were taken by a physician after a 5‐min rest and the mean of 3 measurements was recorded.13Blood samples were drawn after 8–12 h fast. A standard OGTT (1.75 g/kg body weight up to a maximum of 75 g) was performed with flavoured glucose (Glucosio Sclavo Diagnostics, 75 g/150 ml). One anti‐cubital i.v. catheter was inserted for blood sampling and was maintained patent by a normal saline drip during the test. Glucose level was measured by glucose oxidase technique (Cobas Integra, Roche) and insulin by a chemiluminescent immunoassay method (ADVIA Centaur analyser; Bayer Diagnostics). HbA1c was measured using an automated high performance liquid chromatography VARIANT II TURBO Haemoglobin Testing System (Bio Rad, Hercules, CA).
+ Open protocol
+ Expand
2

Platelet-Derived Serotonin Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
Platelet-depleted serum concentration of 5-HT was measured in duplicate using Serotonin FAST Kit (catalog no. EIA5061; DRG instrument GmbH, Marburg, Germany). Its characteristics are as follows: detection range=15–2,500 ng/mL; sensitivity=5 ng/mL.
An aliquot of aspirated platelet rich serum was then used to assess platelet count via Advia Centaur Analyser (Bayer Ltd., Berks, UK). Additional duplicate samples were used for 5-HT analysis of platelet-rich serum, while platelet-depleted serum 5-HT concentrations were measured following centrifugation.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!