The largest database of trusted experimental protocols

6 protocols using ft ir 4600 fourier transform infrared spectrometer

1

Spectroscopic Characterization of Novel Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were determined using a Jasco P-1020 polarimeter. Infrared (IR) spectra were obtained using a Jasco FT/IR-4600 Fourier-transform infrared spectrometer. Proton and carbon nuclear magnetic resonance (1H and 13C NMR) spectra were recorded with chloroform (in CDCl3) on the following instrument: a JEOL JNM-AL500 (1H at 500 MHz and 13C at 125 MHz, JEOL, Tokyo, Japan). Mass spectra were determined by a Bruker Daltonics micrOTOF focus (ESI-TOF) (Bruker, Billerica, MA, USA) mass spectrometer. Thin layer chromatography was performed on a Wakogel B5F. HPLC was performed with a Hitachi LaChrom Elite system composed of an Organizer, L-2400 UV Detector, and L-2130 Pump. All reactions were carried out under an argon atmosphere in dried glassware unless otherwise noted. CH2Cl2 was distilled from diphosphorus pentoxide and then calcium hydride and dried over MS4A; toluene was distilled from diphosphorus pentoxide and dried over MS4A; and THF and diethyl ether were distilled from sodium/benzophenone immediately prior to use. All reagents were purchased from Tokyo Kasei Kogyo Co., Ltd.; Kanto Chemical Co., Inc.; or Aldrich Chemical Co., Inc.; and were used without further purification unless otherwise noted. MNBA was purchased from Tokyo Kasei Kogyo Co., Ltd. (TCI M1439).
+ Open protocol
+ Expand
2

Analytical Techniques for Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were determined using a Jasco P-1020 polarimeter. Infrared (IR) spectra were obtained using a Jasco FT/IR-4600 Fourier transform infrared spectrometer. Proton and carbon nuclear magnetic resonance (1H and 13C NMR) spectra were recorded with chloroform (in CDCl3) on the following instruments: JEOL JNM-AL500 (1H at 500 MHz and 13C at 125 MHz). Mass spectra were determined by a Bruker Daltonics micrOTOF focus (ESI-TOF) mass spectrometer. Thin layer chromatography was performed on Wakogel B5F. HPLC was performed with a Hitachi LaChrom Elite system composed of the Organizer, L-2400 UV Detector, and L-2130 Pump.
+ Open protocol
+ Expand
3

Analytical Techniques for Structural Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Polymerase chain reaction
(PCR) amplifications were reacted by FlexCycler PCR. Optical rotations
were measured with a JASCO P-2000 polarimeter. UV spectra were recorded
on a JASCO V-530 UV–vis spectrophotometer, and experimental
ECD spectra were measured on a JASCO J-815 spectropolarimeter. IR
spectra were obtained on a JASCO FT/IR-4600 Fourier transform infrared
spectrometer. 1D and 2D NMR spectra were performed on a JEOL JNM-ECS
400 MHz NMR spectrometer (1H, 400 MHz; 13C,
100 MHz), Varian Mercury Plus 400 MHz FT-NMR (1H, 400 MHz; 13C, 100 MHz), and Varian VNMRS 600 MHz FT-NMR (1H, 600 MHz; 13C, 150 MHz) in CDCl3, CD3OD, and CD3COCD3, respectively. Mass
spectra were obtained from a Waters 2695 separation module (ESI-MS)
and Bruker FT-MS SolariX (HR-ESI-MS). Column chromatography was carried
out on silica gel 60 (0.063–0.200 mm and 0.040–0.063
mm, Merck) and Sephadex LH-20 (Fine Chemicals AB, Uppsala, Pharmacia).
Thin-layer chromatography (TLC) analyses were performed using silica
gel 60, F254, and RP-18, F254S (0.20 nm, Merck, Germany). Semi-preparative
HPLC was performed on Shimadzu LC-10 AD, Shimadzu LC-20AT, or Jasco
PU-980 pumps, an SPD-M10A diode array, SPD-10A UV–vis or UV-970
UV–vis detectors, and SCL-10A or CBM-20A controllers with Luna
phenyl-hexyl, 100 Å, 250 × 10 mm, Phenomenex or Luna CN,
100 Å, 250 × 10 mm, Phenomenex columns.
+ Open protocol
+ Expand
4

Spectroscopic Analysis of Novel Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All solvents were purchased from Kanto Chemical (Tokyo, Japan). Silica gel and octa-decanoyl-silicon (ODS) were purchased from Fuji Silysia Chemical (Aichi, Japan).
High-resolution electrospray ionization (HR-ESIMS) spectra were measured using an AB Sciex TripleTOF 5600+ System (AB Sciex, Framingham, MA, USA). Nuclear magnetic resonance (NMR) spectra were measured using a JEOL JNM-ECA 500 spectrometer (JEOL, Tokyo, Japan), with 1H-NMR at 500 MHz and 13C NMR at 100 MHz in chloroform-d (CDCl3), methanol-d4 (CD3OD), and acetone-d6 [(CD3)2CO]. The chemical shifts are expressed in parts per million (ppm) and are referenced to residual CHCl3 (7.26 ppm), CHD2OD (3.31 ppm), and CHD2COCD3 (2.05 ppm) in the 1H-NMR spectra and CDCl3 (77.0 ppm), CD3OD (49.0 ppm), and (CD3)2CO (29.8 ppm) in the 13C-NMR spectra. Infrared radiation (IR) spectra (KBr) were taken on a JASCO FT/IR-4600 Fourier Transform Infrared Spectrometer (JASCO, Tokyo, Japan). UV spectra were measured with a Hitachi U-2810 spectrophotometer (Hitachi, Tokyo, Japan). Optical rotation was measured on a JASCO model DIP-1000 polarimeter (JASCO, Tokyo, Japan). X-ray crystal analysis was measured on a RASA-5R (Rigaku, Akishima, Japan).
+ Open protocol
+ Expand
5

Analytical Techniques for Chemical Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
General information. Optical rotations were determined using a Jasco P-1020 polarimeter. Infrared (IR) spectra were obtained using a Horiba FT-330 or Jasco FT/IR-4600 Fourier transform infrared spectrometer.
Proton and carbon nuclear magnetic resonance ( 1 H and 13 C NMR) spectra were recorded on the following instruments: JEOL JNM-AL500 ( 1 H at 500 MHz and 13 C at 125 MHz). Mass spectra were determined by a Bruker Daltonics micrOTOF focus (ESI-TOF) mass spectrometer. Thin layer chromatography was performed on Wakogel B5F. HPLC was performed with a Hitachi LaChrom Elite system composed of the Organizer, L-2400 UV Detector, and L-2130 Pump. All reactions were carried out under argon atmosphere in dried glassware unless otherwise noted. CH2Cl2 was distilled from diphosphorus pentoxide, then calcium hydride, and dried over MS4A, toluene was distilled from diphosphorus pentoxide, and dried over MS4A, and THF and diethyl ether were distilled from sodium/benzophenone immediately prior to use. All reagents were purchased from Tokyo Kasei Kogyo Co., Ltd., Kanto Chemical Co., Inc. or Aldrich Chemical Co., Inc., and used without further purification unless otherwise noted. MNBA was purchased from Tokyo Kasei Kogyo Co. Ltd. (TCI M1439).
+ Open protocol
+ Expand
6

Analytical Techniques for Chemical Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
General information. Optical rotations were determined using a Jasco P-1020 polarimeter. Infrared (IR) spectra were obtained using a Horiba FT-330 or Jasco FT/IR-4600 Fourier transform infrared spectrometer.
Proton and carbon nuclear magnetic resonance ( 1 H and 13 C NMR) spectra were recorded on the following instruments: JEOL JNM-AL500 ( 1 H at 500 MHz and 13 C at 125 MHz). Mass spectra were determined by a Bruker Daltonics micrOTOF focus (ESI-TOF) mass spectrometer. Thin layer chromatography was performed on Wakogel B5F. HPLC was performed with a Hitachi LaChrom Elite system composed of the Organizer, L-2400 UV Detector, and L-2130 Pump. All reactions were carried out under argon atmosphere in dried glassware unless otherwise noted. CH2Cl2 was distilled from diphosphorus pentoxide, then calcium hydride, and dried over MS4A, toluene was distilled from diphosphorus pentoxide, and dried over MS4A, and THF and diethyl ether were distilled from sodium/benzophenone immediately prior to use. All reagents were purchased from Tokyo Kasei Kogyo Co., Ltd., Kanto Chemical Co., Inc. or Aldrich Chemical Co., Inc., and used without further purification unless otherwise noted. MNBA was purchased from Tokyo Kasei Kogyo Co. Ltd. (TCI M1439).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?