The largest database of trusted experimental protocols

Silica gel 60 f254 coated plates

Manufactured by Merck Group
Sourced in United States

Silica gel 60 F254 coated plates are a type of thin-layer chromatography (TLC) plate used for analytical and preparative applications in chemistry. The plates are coated with a layer of silica gel, a common adsorbent material, which allows for the separation and detection of chemical compounds. The F254 indicator incorporated into the coating fluoresces under ultraviolet light, enabling the visualization of separated compounds.

Automatically generated - may contain errors

5 protocols using silica gel 60 f254 coated plates

1

Synthesis and Characterization of Novel Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Solvents were procured from Merck. Thin layer chromatography (TLC), was performed on Silica gel 60 F254 coated plates (Merck) to check the purity of compounds. For performing FT-IR, Perkin Elmer FT-IR spectrophotometer was used. Melting points were determined by Gallenkamp melting point apparatus. 1H and 13C NMR were recorded in Bruker NMR 500/700 MHz and 125/176 MHz spectrophotometer. The samples were run in DMSO-d6 with tetra methyl silane (TMS) as an internal standard. Molecular masses of compounds were determined in GC mass spectroscopy. The CHN Elementar (Analysensysteme GmbH, Germany) was used for elemental analysis of the compounds. Cisplatin was purchased from Sigma-Aldrich, USA. Antibodies against COX-2 and β-actin were purchased from Abcam (Cat Log No: ab15191).
+ Open protocol
+ Expand
2

Spectroscopic Characterization of Synthesized Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
The solvents were procured from Merck. Purity of the synthesized compounds was confirmed by thin layer chromatography (TLC), performed on Silica gel 60 F254 coated plates (Merck, Kenilworth, NJ, USA). UV light was used for the visualization of TLC spots. Spectrum BX, Perkin Elmer FT-IR spectrophotometer (Perkin Elmer, Hopkinton, MA, USA) was used for performing FTIR. Gallenkamp melting point apparatus (Gallenkamp, Loughborough, UK) was used for performing melting points. Bruker NMR 500 MHz and 125 MHz spectrophotometer (Bruker, Billerica, MA, USA) were used for 1H- and 13C-NMR. All the samples were processed in DMSO-d6 with tetramethylsilane (TMS) as internal standard. Mass spectroscopy was used for the measurement of molecular masses of compounds. The elemental analysis of the compounds was performed on the CHN Elementar (Analysensysteme GmbH, Langenselbold, Germany). The elemental analyses were within the limit.
+ Open protocol
+ Expand
3

Characterization of Compound IIb

Check if the same lab product or an alternative is used in the 5 most similar protocols
All the solvents were purchased from Merck (Kenilworth, NJ, USA). To check the purity of compounds, thin layer chromatography (TLC), was performed on silica gel 60 F254 coated plates (Merck). For performing FTIR, Perkin Elmer (Waltham, MA, USA) FT-IR spectrophotometer was used. Melting points were measured by Gallenkamp melting point apparatus. 1H and 13C NMR were recorded in Bruker (Billerica, MA, USA) NMR 500/700 MHz and 125/176 MHz spectrophotometer. The samples were run in DMSO-d6 with tetramethyl silane (TMS) as an internal standard. Molecular weights of compounds were determined in mass spectroscopy. The elemental analysis of compounds was performed by CHN Elementar (Analysensysteme GmbH, Langenselbold, Germany). The compound (IIb) was obtained as single crystal by reported method. Data were collected on a Bruker APEX-II D8 Venture area diffractometer. SHELXT was used to solve structure [41 (link),42 ]. CCDC 1532829 contains the supplementary crystallographic data for the compound (IIb). These data can be obtained free of charge via http://www.ccdc.cam.ac.uk/conts/retrieving.html (or from the CCDC, 12 Union Road, Cambridge CB2 1EZ, UK; Fax: +44 1223 336033; E-mail: deposit@ccdc.cam.ac.uk).
+ Open protocol
+ Expand
4

Extraction and Formulation of Jatrophone

Check if the same lab product or an alternative is used in the 5 most similar protocols
The dichloromethane fraction from J. isabellei (DFJi) was resuspended in a mixture composed of dimethyl sulphoxide (DMSO), polyethylene glycol 400 (PEG 400), and phosphate buffered saline (PBS), pH 7.4 (5:47.5:47.5 v/v) for oral administration (p.o.) in rats. For intravenous administration, the fraction was dissolved in a mixture composed of DMSO, polysorbate 80, and saline solution (5:4:91 v/v). A combination of κ- and λ-carrageenan was purchased from BDH Chemicals Ltd. (London, UK). Dexamethasone and indomethacin were purchased from Deg (São Paulo, Brazil), and colchicine from Sigma-Aldrich (St Louis, MO). The jatrophone isolation from the dichloromethane fraction required the use of Silica Gel 60 and Silica Gel 60 F254-coated plates, which were purchased from Merck (Darmstadt, Germany). Analytical grades hexane, acetone, dichloromethane, ethanol and methanol were purchased from Vetec (Duque de Caxias, Brazil). Acetonitrile HPLC grade was purchased from Panreac (Barcelona, Spain). The ultrapure water utilized in the UFLC analyses was obtained using a Milli-Q purification system (Millipore, Billerica, MA).
+ Open protocol
+ Expand
5

Synthesis of Enaminone Compound

Check if the same lab product or an alternative is used in the 5 most similar protocols
Solvents were procured from Merck. Thin layer chromatography (TLC), was done on Silica gel 60 F254 coated plates (Merck Millipore, Billerica, MA, USA). For performing FT IR, Perkin Elmer FT-IR instrument was used (PerkinElmer Inc., Waltham, MA, USA). Gallenkamp melting point apparatus was used for the determination of melting point. Proton and carbon NMR were recorded in Bruker NMR 700/500 MHz and 176.0/125 MHz spectrophotometer (Bruker Corporation, Billerica, MA, USA). All the samples were dissolved in deuterated dimethyl. Molecular ions of compounds were detected by GC/MS mass spectroscopy. The elemental analysis of the compounds was performed by CHN Elementar (Analysensysteme GmbH, Langenselbold, Germany).
Enaminone (III), 1-(2,3-dihydro-1,4-benzodioxin-6-yl)-3-(dimethylamino)prop-2-en-1-one, was synthesized by refluxing 1-(2,3-dihydro-1,4-benzodioxin-6-yl)ethan-1-one (I) with dimethylformamide dimethyl acetal (DMF-DMA) (II) under solvent-free conditions for 10 hours.24 (link)
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!