The largest database of trusted experimental protocols

Facscanto 2 facp array software

Manufactured by BD

The FACSCanto II FACP Array™ software is a flow cytometry analysis tool. It is designed to facilitate the visualization and analysis of multiparametric flow cytometry data.

Automatically generated - may contain errors

3 protocols using facscanto 2 facp array software

1

Apoptosis Analysis of RAW264.7 Cells

Check if the same lab product or an alternative is used in the 5 most similar protocols
Following transfection for 48 h, an Annexin V-fluorescein isothiocyanate (FITC)/propidium iodide (PI) Apoptosis Detection kit (BD Biosciences) was used to analyze the apoptotic level of RAW264.7 cells. The RAW264.7 cells were collected with trypsin and washed with PBS, and then resuspended in 500 µl HEPES buffer solution (Sigma-Aldrich; Merck KGaA) and incubated with 5 µl Annexin V-FITC and 5 µl PI at room temperature for 15 min in the dark. Finally, a FACSVerse™ flow cytometer with the FACSCanto II FACP Array™ software (v.3.0; BD Biosciences) was used to analyze the RAW264.7 cell apoptosis data.
+ Open protocol
+ Expand
2

Annexin V-FITC/PI Apoptosis Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cells were stained using an Annexin V/Propidium Iodide (PI) Apoptosis Detection Kit (BD Biosciences, Franklin Lakes, NJ, USA) 48 h following transfection. The cells were seeded into 6-well plates (4×105 cells/well). Following transfection, the cells were collected, washed with PBS, and resuspended in 500 µl HEPES buffer solution (Sigma-Aldrich; Merck KGaA, Darmstadt, Germany). Subsequently, 5 µl Annexin V-FITC and 5 µl PI were added to the buffer and incubated at room temperature for 15 min in the dark. The apoptosis rate was analyzed using a FACSVerse flow cytometer with the FACSCanto II FACP Array software (version 3.0; BD Biosciences).
+ Open protocol
+ Expand
3

Apoptosis Analysis of IEC-6 Cells

Check if the same lab product or an alternative is used in the 5 most similar protocols
After transfection for 48 h, an Annexin V-fluorescein isothiocyanate (FITC)/propidium iodide (PI) Apoptosis Detection kit (BD Biosciences) was used to analyze the apoptosis of the IEC-6 cells. The cells were collected with trypsin, washed with PBS, and resuspended in 500 µl HEPES buffer solution (Sigma-Aldrich; Merck KGaA). The cells were then incubated with 5 µl Annexin V-FITC and 5 µl PI at room temperature for 15 min in the dark. Finally, a FACSVerse™ flow cytometer with FACSCanto II FACP Array™ software (v.3.0; both BD Biosciences) was used to analyze apoptosis.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!