The largest database of trusted experimental protocols

Bs 180

Manufactured by Mindray
Sourced in China

The BS-180 is a fully automated hematology analyzer designed for mid-volume laboratory settings. It performs routine blood cell analysis, including red blood cell count, hemoglobin concentration, and white blood cell differential. The BS-180 utilizes sophisticated technology to deliver accurate and reliable results.

Automatically generated - may contain errors

13 protocols using bs 180

1

Measuring Cytokine and Antibody Levels in PCV2 Infection

Check if the same lab product or an alternative is used in the 5 most similar protocols
The cytokines IL-10 (431414, BioLegend), IL-2 (431004, BioLegend), IL-6 (431304, BioLegend), IL-12 (433604, BioLegend), TNF-α (430904, BioLegend), IFN-α (BMS6027, Invitrogen), and IFN-γ (430804, BioLegend) were measured by the commercial enzyme-linked immunosorbent assay (ELISA) kits following the manufacturer’s instruction. The IgG contents were detected by an automatic biochemical analyzer (BS-180, mindray, China). The PCV2-specific antibody production was detected as the previously reported (Li et al., 2016 (link)), that the purifed recombinant Cap protein without nuclear localization signal expressed by pET-32a were used to coat 96-well plates, the coating plates were used for the detection. For pulmonary antibodies measurement, the right lungs were cut into pieces in tubes, and the supernatants after centrifugation were used for analyses.
+ Open protocol
+ Expand
2

Plasma Glucose and Liver Enzymes Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma glucose, alanine aminotransferase (ALT), and aspartate aminotransferase (AST) levels were measured using a biochemical analyzer (Mindray BS 180, China), and the AST/ALT ratio was calculated.
+ Open protocol
+ Expand
3

Liver Fat Deposition and Lipid Levels

Check if the same lab product or an alternative is used in the 5 most similar protocols
The intact liver was removed after the rats were sacrificed, and the liver/body weight ratio was calculated to evaluate the amount of fat deposited in the liver. The TG and TC levels in the plasma were measured using a fully automatic bio-analysis machine (Mindray BS 180, China). TG and TC levels in liver tissue homogenates were determined using an ELISA kit (Nanjing Jiancheng, China).
+ Open protocol
+ Expand
4

Comprehensive Biochemical Profiling Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
As described in previous reports,[23 (link), 24 (link)] blood glucose (BG) was measured with the hexokinase method. Triglyceride (TG), total cholesterol (TC), low-density lipoprotein cholesterol (LDL-C), and high-density lipoprotein cholesterol (HDL-C) were determined using Mindray’s kit and biochemical detector (BS-180; Mindray, Shenzhen, China). Glycated hemoglobin (HbA1c) was assayed with Bio-Rad reagents. SUA was measured using the uricase– peroxidase coupling method (ROCHE COBAS 8000).
+ Open protocol
+ Expand
5

Physiological Monitoring of Rat Serum and Blood Gases

Check if the same lab product or an alternative is used in the 5 most similar protocols
An automatic biochemical analyzer (BS-180, Shenzhen Mindray, Bio-Medical Electronics Co., Ltd., Shenzhen, China) was used to determine the K+ concentration in the serum. The main carotid artery intubation was connected to a RM6240 multichannel physiological monitor (Chengdu Instrument Factory, Chengdu, China) to measure the mean arterial pressure (MAP) and heart rate (HR) of the rats. Changes in the blood pH, PaO2, PaCO2 and base excess (BE) of the rats were analyzed using a bayer-248 blood gas analyzer (Bayer AG, Leverkusen, Germany).
+ Open protocol
+ Expand
6

Comprehensive Blood Analysis of Calves

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood samples were collected from the external jugular vein of all calves at 10, 35, and 70 days of age for hematological (mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), erythrocytes, hematocrit, hemoglobin, leukocytes, thrombocytes, cell distribution width (RDW), and mean corpuscular volume (MPV)) and biochemical analyses (alanine transaminase (ALT) and aspartate transaminase (AST)) and for determination of selenium concentration. Hematological analyses were carried out using a HORIBA SCIL VET ABC instrument (Horiba Medical, USA) immediately after the blood samples were collected. For the assessment of biochemical parameters (ALT, AST, and selenium level), blood was collected into heparinized tubes and later centrifuged at 5000× g rpm for 10 min at room temperature. The obtained plasma was divided into Eppendorf tubes for individual analyses and frozen at −20 °C. Biochemical analyses of plasma parameters were performed on a Mindray BS-180 (China) apparatus using commercial CORMAY kits (Lublin, Poland). The selenium level was tested by IDEXX laboratory (Kornwesthei, Germany) using an ICP-MS analyzer with an Se-78 isotope.
+ Open protocol
+ Expand
7

Comprehensive Metabolic Biomarker Assessment

Check if the same lab product or an alternative is used in the 5 most similar protocols
The blood lipid-related indexes: total cholesterol (TC, mmol/L), triglyceride (TG, mmol/L), high-density lipoprotein cholesterol (HDL-C, mmol/L) and low-density lipoprotein cholesterol (LDL-C, mmol/L); uric acid (UA, mmol/L), aspartate aminotransferase, alanine aminotransferase, blood calcium and serum phosphate (mmol/L) using test kit and biochemical analyser (BS-180, Mindray company). Fasting plasma glucose (FPG, mmol/L) and 2 h blood glucose after OGTT load (2 h PG, mmol/L) were determined by glucose oxidase method using test kit and biochemical analyzer (BS-180, Mindray Company). Glycosylated hemoglobin (HbA1c, %) using BioRad reagent, measured by VARIANT II (BioRad Company). Thyroid-stimulating hormone (TSH, mIU/L), Free thyroxine (FT4, pmol/L) anti-thyroid peroxidase antibody (TPOAb, 0–34IU/L) and anti-thyroid globulin antibody (TgAb, IU/L) using ICMA (Roche Company). Urinary iodine (UIC, g/L) was determined by inductively coupled plasma mass spectrometer (7700×, Agilent, USA).
+ Open protocol
+ Expand
8

Hematological and Biochemical Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
White and red blood cell counts, mean cell volumes, mean corpuscular hemoglobin concentrations, and packed cell volumes were analyzed with an auto hematology analyzer (BC-2800; Shenzhen Mindray Bio-Medical Electronics Co., Ltd, Shenzhen, People’s Republic of China). Serum enzyme activities were measured by use of an automatic biochemical analyzer (BS-180; Shenzhen Mindray Bio-Medical Electronics Co., Ltd).
+ Open protocol
+ Expand
9

Blood Separation and Analysis Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
The serum was separated by centrifuging the blood samples for 10 minutes at 1500g, and was stored at −20°C until analyses of creatinine (Cr) and blood urea nitrogen (BUN) levels with an automatic biochemical analyzer (BS‐180; Shenzhen Mindray Bio‐Medical Electronics Co, Ltd, Shenzhen, China).
+ Open protocol
+ Expand
10

Serum Creatinine and Blood Urea Nitrogen Measurement

Check if the same lab product or an alternative is used in the 5 most similar protocols
Serum creatinine (Scr) and blood urea nitrogen (BUN) were measured using BS-180 automatic biochemistry analyzer (Mindray, Shenzhen, China) following the manufacturer's instructions.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!