The largest database of trusted experimental protocols

Sekm 0002

Manufactured by Solarbio
Sourced in China

The SEKM-0002 is a piece of lab equipment designed for the analysis and separation of biological samples. It features a compact and durable construction, making it suitable for use in various research and testing environments.

Automatically generated - may contain errors

7 protocols using sekm 0002

1

Cytokine Profiling in Lung Tissues

Check if the same lab product or an alternative is used in the 5 most similar protocols
The levels of IL-6 (SEKM-0007 and SEKH-0013, Solarbio), tumor necrosis factor-α (TNF-α) (SEKM-0034 and SEKH-0047, Solarbio), IL-10 (SEKM-0010 and SEKH-0018, Solarbio), IL-18 (SEKH-0028 and SEKM-0019), and IL-1β (SEKM-0002 and SEKH-0002) in lung tissues and cell cultures were measured according to the instructions.
+ Open protocol
+ Expand
2

Measurement of Inflammatory Biomarkers

Check if the same lab product or an alternative is used in the 5 most similar protocols
ELISA kits for the detection of Lp-PLA2 (CSB-E08321m, Cusabio, USA), TNF-α (SEKM-0034, Solarbio, China), IL-6 (SEKM-0007, Solarbio, China) and IL-1β (SEKM-0002, Solarbio, China) were obtained from Solarbio (Solarbio, Beijing, China). The levels of Lp-PLA2, TNF-α, IL-6 and IL-1β were analysed with corresponding ELISA kits according to the manufacturer's instructions. Then, the absorbance of the coloured product was measured at 405 nm by an automated plate reading system (FlexStation 3, Molecular Device, Sunnyvale, CA, USA). Each experiment was independently performed three times.
+ Open protocol
+ Expand
3

Spinal Cord Cytokine Expression

Check if the same lab product or an alternative is used in the 5 most similar protocols
The protein expression of interleukin (il)-1β, tumor necrosis factor (TnF)-α and il-6 in lumbar dorsal spinal cord tissue homogenates were measured using commercially available eliSa kits (SEKM-0002, SEKM-0034 and SEKM-0007; Solarbio life Science), according to the manufacturer's protocols. The experiment was repeated three times, and the mean value was used.
Statistical analysis. SPSS (version 18.0; SPSS, inc.) was used for data analysis. data were presented as the mean ± standard deviation. comparisons between two groups were estimated by a Student's t-test, whereas multiple group comparisons were carried out by one-way anoVa analysis with a Bonferroni's post hoc test. P<0.05 was considered to indicate a statistically significant difference.
+ Open protocol
+ Expand
4

Cytokine Profiling in Serum

Check if the same lab product or an alternative is used in the 5 most similar protocols
The levels of interleukin 6 (IL-6) (PI326; Beyotime, Beijing, China), tumor necrosis factor-α (TNF-α) (SEKM-0034, Solarbio), interleukin 1β (IL-1β) (SEKM-0002, Solarbio) in serum were detected using ELISA kits.
+ Open protocol
+ Expand
5

Measuring Inflammatory Markers and Cardiac Injury

Check if the same lab product or an alternative is used in the 5 most similar protocols
Mouse serum or HL-1 cell supernatant was collected. The levels of tumor necrosis factor α (TNF-α), interleukin (IL)-1β, IL-6, and cardiac troponin I (cTnI) were measured separately using the corresponding ELISA kits according to the manufacturer’s instructions. The kits included TNF-α (SEKM-0034; Solarbio), mouse IL-6 (SEKM-0007; Solarbio), IL-1β (SEKM-0002; Solarbio), and mouse cTnI (KS11280; Keshun Science and Technology, Shanghai, China).
+ Open protocol
+ Expand
6

ELISA Quantification of Alzheimer's Biomarkers

Check if the same lab product or an alternative is used in the 5 most similar protocols
The concentrations of Aβ1-42 (CSB-E10787m, Cusabio, Hubei, China), Aβ1-40 (CSB-E08300m,Cusabio), IL-1β (SEKM-0002, Solarbio, Beijing, China), and TNF-α (SEKM-0034, Solarbio) were assessed by enzyme-linked immunosorbent (ELISA) assay kits. In brief, cells were seeded onto 96-well plates and treated under different conditions. Thereafter, 100 μL of supernatants was harvested to perform ELISA assays. Nitric oxide levels were detected according to total nitrate/nitrite ratios in the supernatants following the manufacturer’s instructions (Nitric Oxide Assay Kit, EMSNO, Pierce, Rockford, IL). Briefly, nitrate reductase and the enzyme cofactor were added to wells and incubated to convert nitrate to nitrite. Next, the enhancers were added and incubated at room temperature. Finally, the Griess reagents were added and the samples were analyzed with a microplate reader.
+ Open protocol
+ Expand
7

Cytokine Quantification in Lung Tissue

Check if the same lab product or an alternative is used in the 5 most similar protocols
Freshly prepared lungs were homogenized with a tissue homogenizer. The homogenate was placed in a benchtop refrigerated centrifuge and centrifuged at 3000 rpm for 20 min. The supernatant was collected after centrifugation. TNF-α (PT513, Solarbio Science & Technology Co., Ltd, Beijing, China), IL-1β (SEKM-0002, Solarbio Science & Technology Co., Ltd, Beijing, China) and IL-6 (SEKM-0007, Solarbio Science & Technology Co., Ltd, Beijing, China) assays were performed according to the instructions of the ELISA kit.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!