Chromatography: ACE-3 C18 column (pre-column), dimensions 100 × 2.1 mm, 2.7 μm, at 25 °C, flow rate of 0.4 ml/min at wavelengths 408, 440 and 450 nm, using a linear gradient of methanol in MTBE as the mobile phase (step A: methanol, step B: MTBE, gradient: 0 min = 0% B, 20 min = 20% B, 24 min = 50% B, 30 min. = 100% B). Mass spectrometry conditions: APCI ionization, positive mode, flow 0.240 ml/h, scanning 120–1200 m/z, capillary 3500 V, nebulizer 0.6 Bar, N2 temperature: 180 °C and flow rate of N2: 5 l/min. The identification of the substances was carried out based on the fragmentation profiles in comparison with literature data. The mass measurement was made at a resolution of 20.000.
Microtof
The MicroTOF is a high-performance Time-of-Flight (TOF) mass spectrometer designed for accurate mass determination. It features a compact design and delivers high sensitivity and resolution for a wide range of analytical applications.
Lab products found in correlation
131 protocols using microtof
Carotenoid Profiling by HPLC-MS/MS
Chromatography: ACE-3 C18 column (pre-column), dimensions 100 × 2.1 mm, 2.7 μm, at 25 °C, flow rate of 0.4 ml/min at wavelengths 408, 440 and 450 nm, using a linear gradient of methanol in MTBE as the mobile phase (step A: methanol, step B: MTBE, gradient: 0 min = 0% B, 20 min = 20% B, 24 min = 50% B, 30 min. = 100% B). Mass spectrometry conditions: APCI ionization, positive mode, flow 0.240 ml/h, scanning 120–1200 m/z, capillary 3500 V, nebulizer 0.6 Bar, N2 temperature: 180 °C and flow rate of N2: 5 l/min. The identification of the substances was carried out based on the fragmentation profiles in comparison with literature data. The mass measurement was made at a resolution of 20.000.
Peptide Synthesis and Characterization
Synthesis of Blue Fluorescent Compound
the method described in general procedure 3, using
μmol, 30%). HRMS (Bruker MicroTOF)(m/z): Calculated
(M+H)+ for C69H79B1F2N10O11S1 = 1305.5784; measured
= 1305.5757. Analytical HPLC (system 1): 98% purity; tR= 18.28 min.
Synthesis of Lys-Ala-Asn-Ser-Leu Peptide
the method described in general procedure 1, using Fmoc-Lys(Boc)-OH
(94 mg, 0.20 mmol) for the loading phase; Fmoc-ß-Ala-OH (63 mg,
0.20 mmol), Fmoc-Asn(Trt)-OH (120 mg, 0.20 mmol), Fmoc-Ser(tBu)-OH
(77 mg, 0.20 mmol), and Fmoc-Leu-OH (71 mg, 0.20 mmol) for four separate
coupling phases in the stated sequence;
mmol) for the capping phase to afford a colorless solid (1.3 mg, 1.53
μmol, 4%). HRMS (Bruker MicroTOF)(m/z): Calculated
(M+H)+ for C43H65N9O9 = 852.4978; measured = 852.4964. Analytical HPLC (system
1): 94% purity; tR = 12.62 min.
Synthesis of Fluorescent Probe Compound
the method described in general procedure 2, using
μmol, 54%). HRMS (Bruker MicroTOF)(m/z): Calculated
(M+H)+ for C65H76B1F2N13O10S1 = 1280.5693; measured
= 1280.5718. Analytical HPLC (system 1): 98% purity; tR = 15.92 min
Synthesis of Fluorinated Macrocyclic Compound
the method described in general procedure 2, using
μmol, 67%). HRMS (Bruker MicroTOF)(m/z): Calculated
(M+H)+ for C60H67B1F2N12O9S1 = 1181.5009; Measured
= 1181.4954; Error = 5.5ppm. Analytical HPLC (system 1): 96% purity; tR = 15.90 min.
Synthesis of Blue Solid Compound
the method described in general procedure 3, using
μmol, 45%). HRMS (Bruker MicroTOF)(m/z): Calculated
(M+H)+ for C65H78B1F2N11O10S1 = 1254.5788; measured
= 1254.5761. Analytical HPLC (system 1): 98% purity; tR= 18.15 min.
Synthesis of Blue Fluorescent Compound
the method described in general procedure 4, using
μmol, 60%). HRMS (Bruker MicroTOF)(m/z): Calculated
(M+H)+ for C71H89B1F2N12O12S1 = 1383.6578; measured
= 1383.6513. Analytical HPLC (system 1): 98% purity; tR = 16.31 min.
Solid-Phase Peptide Synthesis of Compound 7
the method described in general procedure 1, using Fmoc-Lys(Boc)-OH
(94 mg, 0.20 mmol) for the loading phase; Fmoc-ß-Ala-OH (63 mg,
0.20 mmol), Fmoc-Tyr(tBu)-OH (80 mg, 0.20 mmol), Fmoc-Ala-OH (63 mg,
0.20 mmol), and Fmoc-Thr(tBu)-OH (68 mg, 0.20 mmol) for four separate
coupling phases in the stated sequence;
mmol) for the capping phase to afford a colorless solid (2.3 mg, 2.64
μmol, 7%). HRMS (Bruker MicroTOF)(m/z): Calculated
(M+H)+ for C46H64N8O9 = 873.4869; measured = 873.4842. Analytical HPLC (system
1): 98% purity; tR= 12.00
min.
Synthesis of Fluorescent Boron Complex
the method described in general procedure 3, using
μmol, 29%). HRMS (Bruker MicroTOF)(m/z): Calculated
(M+H)+ for C66H80B1F2N11O11S1 = 1284.5893; measured
= 1284.5844. Analytical HPLC (system 1): 95% purity; tR = 18.03 min.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!