Carotenoid Profiling by HPLC-MS/MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
The analysis of the crude carotenoid fraction with high performance liquid chromatography coupled to mass spectrometry (HPLC-MS/MS) was performed in a MicrOTOF Bruker® Daltonics GmbH mass spectrometer using APCI ionization coupled to an Agilent® Infinity 1260 chromatograph.
Chromatography: ACE-3 C18 column (pre-column), dimensions 100 × 2.1 mm, 2.7 μm, at 25 °C, flow rate of 0.4 ml/min at wavelengths 408, 440 and 450 nm, using a linear gradient of methanol in MTBE as the mobile phase (step A: methanol, step B: MTBE, gradient: 0 min = 0% B, 20 min = 20% B, 24 min = 50% B, 30 min. = 100% B). Mass spectrometry conditions: APCI ionization, positive mode, flow 0.240 ml/h, scanning 120–1200 m/z, capillary 3500 V, nebulizer 0.6 Bar, N2 temperature: 180 °C and flow rate of N2: 5 l/min. The identification of the substances was carried out based on the fragmentation profiles in comparison with literature data. The mass measurement was made at a resolution of 20.000.
+ Open protocol
+ Expand
2

Peptide Synthesis and Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
The peptides were synthesized using an automated ResPepXL peptide synthesizer (Intavis AG, Bioanalytical Instruments) and operated with a Multiple-Parallel Peptide Synthesis Program and were purified by HPLC using Shimadzu LC-20AT, column TSK gel amide-80 (3 µm, 300 x 7.8 mm) equipped by an UV photodiode array detector (SPD-M20A). The UV detection was performed at 214 nm. The analysis by HPLC were performed using the same equipment with a column TSK gel amide-80 (3 µm, 150 × 4.6 mm). 1 (link) H NMR spectra were recorded on a Brucker Advance III 400 MHz spectrophotometer. The spectra were recorded in DMSO-d6 at room temperature (T = 298 K) and residual peak of DMSO (δ = 2.5 ppm) was used as internal reference. The chemical shifts (δ) are given in parts per million (ppm). High resolution mass spectrometry (HRMS) experiments were performed on a microTOF Bruker (electrospray ionization ESI+, 50-1000 in low and 50-2500 in width).
+ Open protocol
+ Expand
3

Synthesis of Blue Fluorescent Compound

Check if the same lab product or an alternative is used in the 5 most similar protocols
The title compound was synthesized following
the method described in general procedure 3, using 29h (2.3 mg, 2.64 μmol) to afford a blue solid (1.04 mg, 0.80
μmol, 30%). HRMS (Bruker MicroTOF)(m/z): Calculated
(M+H)+ for C69H79B1F2N10O11S1 = 1305.5784; measured
= 1305.5757. Analytical HPLC (system 1): 98% purity; tR= 18.28 min.
+ Open protocol
+ Expand
4

Synthesis of Lys-Ala-Asn-Ser-Leu Peptide

Check if the same lab product or an alternative is used in the 5 most similar protocols
The title compound was synthesized following
the method described in general procedure 1, using Fmoc-Lys(Boc)-OH
(94 mg, 0.20 mmol) for the loading phase; Fmoc-ß-Ala-OH (63 mg,
0.20 mmol), Fmoc-Asn(Trt)-OH (120 mg, 0.20 mmol), Fmoc-Ser(tBu)-OH
(77 mg, 0.20 mmol), and Fmoc-Leu-OH (71 mg, 0.20 mmol) for four separate
coupling phases in the stated sequence; 7 (34 mg, 0.10
mmol) for the capping phase to afford a colorless solid (1.3 mg, 1.53
μmol, 4%). HRMS (Bruker MicroTOF)(m/z): Calculated
(M+H)+ for C43H65N9O9 = 852.4978; measured = 852.4964. Analytical HPLC (system
1): 94% purity; tR = 12.62 min.
+ Open protocol
+ Expand
5

Synthesis of Fluorescent Probe Compound

Check if the same lab product or an alternative is used in the 5 most similar protocols
The title compound was synthesized following
the method described in general procedure 2, using 27a (0.9 mg, 1.06 μmol) to afford a blue solid (0.73 mg, 0.57
μmol, 54%). HRMS (Bruker MicroTOF)(m/z): Calculated
(M+H)+ for C65H76B1F2N13O10S1 = 1280.5693; measured
= 1280.5718. Analytical HPLC (system 1): 98% purity; tR = 15.92 min.
+ Open protocol
+ Expand
6

Synthesis of Fluorinated Macrocyclic Compound

Check if the same lab product or an alternative is used in the 5 most similar protocols
The title compound was synthesized following
the method described in general procedure 2, using 21a (0.5 mg, 0.67 μmol) to afford a blue solid (0.53 mg, 0.45
μmol, 67%). HRMS (Bruker MicroTOF)(m/z): Calculated
(M+H)+ for C60H67B1F2N12O9S1 = 1181.5009; Measured
= 1181.4954; Error = 5.5ppm. Analytical HPLC (system 1): 96% purity; tR = 15.90 min.
+ Open protocol
+ Expand
7

Synthesis of Blue Solid Compound

Check if the same lab product or an alternative is used in the 5 most similar protocols
The title compound was synthesized following
the method described in general procedure 3, using 29b (2.4 mg, 2.92 μmol) to afford a blue solid (1.65 mg, 1.32
μmol, 45%). HRMS (Bruker MicroTOF)(m/z): Calculated
(M+H)+ for C65H78B1F2N11O10S1 = 1254.5788; measured
= 1254.5761. Analytical HPLC (system 1): 98% purity; tR= 18.15 min.
+ Open protocol
+ Expand
8

Synthesis of Blue Fluorescent Compound

Check if the same lab product or an alternative is used in the 5 most similar protocols
The title compound was synthesized following
the method described in general procedure 4, using 29a (1.3 mg, 1.55 μmol) to afford a blue solid (1.28 mg, 0.93
μmol, 60%). HRMS (Bruker MicroTOF)(m/z): Calculated
(M+H)+ for C71H89B1F2N12O12S1 = 1383.6578; measured
= 1383.6513. Analytical HPLC (system 1): 98% purity; tR = 16.31 min.
+ Open protocol
+ Expand
9

Solid-Phase Peptide Synthesis of Compound 7

Check if the same lab product or an alternative is used in the 5 most similar protocols
The title compound was synthesized following
the method described in general procedure 1, using Fmoc-Lys(Boc)-OH
(94 mg, 0.20 mmol) for the loading phase; Fmoc-ß-Ala-OH (63 mg,
0.20 mmol), Fmoc-Tyr(tBu)-OH (80 mg, 0.20 mmol), Fmoc-Ala-OH (63 mg,
0.20 mmol), and Fmoc-Thr(tBu)-OH (68 mg, 0.20 mmol) for four separate
coupling phases in the stated sequence; 7 (34 mg, 0.10
mmol) for the capping phase to afford a colorless solid (2.3 mg, 2.64
μmol, 7%). HRMS (Bruker MicroTOF)(m/z): Calculated
(M+H)+ for C46H64N8O9 = 873.4869; measured = 873.4842. Analytical HPLC (system
1): 98% purity; tR= 12.00
min.
+ Open protocol
+ Expand
10

Synthesis of Fluorescent Boron Complex

Check if the same lab product or an alternative is used in the 5 most similar protocols
The title compound was synthesized following
the method described in general procedure 3, using 29j (1.3 mg, 1.53 μmol) to afford a blue solid (0.59 mg, 0.44
μmol, 29%). HRMS (Bruker MicroTOF)(m/z): Calculated
(M+H)+ for C66H80B1F2N11O11S1 = 1284.5893; measured
= 1284.5844. Analytical HPLC (system 1): 95% purity; tR = 18.03 min.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!