The largest database of trusted experimental protocols

Winnonlin professional 4

Manufactured by Pharsight
Sourced in United States

WinNonlin Professional 4.0.1 is a software application designed for pharmacokinetic and pharmacodynamic data analysis. It provides tools for modeling, simulation, and visualization of drug concentration and response data.

Automatically generated - may contain errors

Lab products found in correlation

4 protocols using winnonlin professional 4

1

Rabbit Pharmacokinetic Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma concentration–time curves were constructed and the pharmacokinetic parameters [namely: Cmax (µg/mL), Tmax (hour), AUC0–4, and AUC0–∞ (μg⋅h/mL), K (hour−1), and t1/2 (hour)] for each rabbit were calculated and manipulated using WinNonlin Professional 4.0.1 software (Pharsight Corp., Cary, NC, USA).
+ Open protocol
+ Expand
2

Pharmacokinetic Analysis of Rabbit Plasma

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma concentration–time curves were constructed, and the pharmacokinetic parameters [namely Cmax (μg/mL), Tmax (hour, h), AUC0–8 and AUC0–∞ (μg.h/mL), Kel (hour−1, h−1), and t1/2 (hour, h)] for each rabbit were calculated and manipulated using WinNonlin Professional 4.0.1 software (Pharsight Corp., Cary, NC, USA).
+ Open protocol
+ Expand
3

Rabbit Pharmacokinetic Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma concentration time curves were constructed and the data were manipulated using WinNonlin Professional 4.0.1 software (Pharsight Corp., Cary, NC, USA), followed by calculation of pharmacokinetic parameters (Cmax (ng/mL), Tmax (hour), AUC0–24 and AUC0–∞ (ng·hour/mL, Kel (hours−1), and t1/2 (hours)) for each rabbit.
+ Open protocol
+ Expand
4

Rabbit Pharmacokinetic Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma concentration-time curves were constructed and the pharmacokinetic parameters [namely: Cpmax (μg/mL), Tmax (h), AUC0–24 and AUC0–∞ (μg h/mL), Kel (h−1) and t1/2 (h)] for each rabbit were calculated and manipulated using WinNonlin Professional 4.0.1 software (Pharsight Corp., Cary, NC).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!