The largest database of trusted experimental protocols

2 protocols using 5 bromo 2 hydroxybenzaldehyde

1

Synthesis of Tungsten-Based Heterogeneous Catalyst

Check if the same lab product or an alternative is used in the 5 most similar protocols
4-Aminobenzoic hydrazide, 5-bromo-2-hydroxybenzaldehyde, tungsten(vi) chloride (WCl6), propionyl chloride-functionalized silica gel (1 mmol g−1 loading) and solvents were purchased from Sigma-Aldrich and used as received. FT-IR spectra were recorded as KBr disks with a Bruker FT-IR spectrophotometer. The UV-Vis spectra of solution were recorded on a thermos-spectronic Helios Alpha spectrophotometer between 200-800 nm. The 1H and 13C NMR spectra were taken from Bruker DRX-300 spectrometer in DMSO-d6 solution. Diffuse-reflectance UV-Vis spectroscopy (DRS) were recorded with Sinco S4100 instrument. Elemental analyses (C, H, N) were performed on a Carlo ERBA Model EA 1108 analyzer and the tungsten content of the compounds was measured by atomic absorption spectroscopy using a Varian AA-220 instrument. Thermal gravimetric analysis (TGA) curves were taken from TA Q600 instrument in the range of 25–1000 °C. X-ray diffraction analyses (XRD) for heterogeneous catalyst were obtained from PHILIPS PW1730 instrument. Energy-dispersive X-ray spectroscopy (EDX) and scanning electron microscopy (SEM) were recorded with TESCAN MIRA III instrument. X-ray photoelectron spectroscopy (XPS) analysis was performed by using a Bes Tec 8025 instrument.
+ Open protocol
+ Expand
2

Synthesis and Characterization of Heteroaromatic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
1,10-phenanthrolin-5-amine, 5-bromo-2-hydroxybenzaldehyde, and thiophene-3-carbaldehyde were procured from Sigma (Sigma, Mumbai, India), and S.D. Chemicals (RD Chem, Mumbai, India) and used without further purification. All the solvents were obtained from Merck (Goa, India), which were dried before using them in the experiments. Thin Layer Chromatography (TLC) was used to check the completion of reaction by spotting the reaction mixture on pre-coated silica-gel plates (Merck, Mumbai, India) and the spots were visualized by UV irradiation. Infrared spectral studies were performed on Perkin-Elmer spectrometer (PerkinElmer, Waltam, MA, USA) version 10.03.09 (KBr pellet technique). 1H and 13C NMR were recorded on a 500 MHz Bruker Avance DPX spectrometer (Bruker, Ettlingen, Germany) with TMS as internal standard. Mass spectra (ESI-MS) of the compounds were measured on Agilent mass spectrometer (Agilent, Santa Clara, CA, USA). The UV-Visible absorption spectra were recorded using UV-1800 spectrophotometer (Shimadzu, Koyto, Japan).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!