The largest database of trusted experimental protocols

14c standards

Manufactured by GE Healthcare

[14C] standards are radioactive reference materials used to calibrate and verify the performance of radiation detection equipment. They provide a consistent and reliable source of radioactivity for laboratory testing and quality control purposes.

Automatically generated - may contain errors

2 protocols using 14c standards

1

Quantification of Neurotransmitter Receptors

Check if the same lab product or an alternative is used in the 5 most similar protocols
We used 5-month-old naïve OM and S5B rats. Slides with mounted brain sections at the level of dorsal striatum that were stored at −80°C were gradually brought back to room temperature and then exposed to receptor autoradiography procedures using [3H]spiperone, [3H]SCH23390, [3H]MPEP, and [3H]SR141716A as previously described21 (link), 26 (link)–28 (link). Radioactivity concentrations were verified via liquid scintillation counting. For [3H]spiperone and [3H]SCH23390 experiments, slides were placed in BAS-TR 2025 (GE Healthcare, Piscataway, NJ) phosphor imaging plates for 7 days along with [14C] standards (GE Healthcare, Piscataway, NJ) (calibrated against 3H-impregnated brain paste standards). Imaging plates were developed using an FLA-7000 phosphorimager (GE Healthcare, Piscataway NJ). Using Multigauge® software (GE Healthcare, Piscataway, NJ), regions of interest (ROIs) were drawn on the dorsolateral (DLST) and dorsomedial striatum (DMST) of each section. Values were averaged and initially expressed as PSL/mm2 and subsequently converted to dpm/mg with the use of [14C] standards. For [3H]MPEP and [3H]SR141716A experiments, slides were imaged using a β-imager (Biospace Lab, France). Scanning and image analysis methods were performed as previously described21 (link).
+ Open protocol
+ Expand
2

Quantification of Neurotransmitter Receptors

Check if the same lab product or an alternative is used in the 5 most similar protocols
We used 5-month-old naïve OM and S5B rats. Slides with mounted brain sections at the level of dorsal striatum that were stored at −80°C were gradually brought back to room temperature and then exposed to receptor autoradiography procedures using [3H]spiperone, [3H]SCH23390, [3H]MPEP, and [3H]SR141716A as previously described21 (link), 26 (link)–28 (link). Radioactivity concentrations were verified via liquid scintillation counting. For [3H]spiperone and [3H]SCH23390 experiments, slides were placed in BAS-TR 2025 (GE Healthcare, Piscataway, NJ) phosphor imaging plates for 7 days along with [14C] standards (GE Healthcare, Piscataway, NJ) (calibrated against 3H-impregnated brain paste standards). Imaging plates were developed using an FLA-7000 phosphorimager (GE Healthcare, Piscataway NJ). Using Multigauge® software (GE Healthcare, Piscataway, NJ), regions of interest (ROIs) were drawn on the dorsolateral (DLST) and dorsomedial striatum (DMST) of each section. Values were averaged and initially expressed as PSL/mm2 and subsequently converted to dpm/mg with the use of [14C] standards. For [3H]MPEP and [3H]SR141716A experiments, slides were imaged using a β-imager (Biospace Lab, France). Scanning and image analysis methods were performed as previously described21 (link).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!