2k ccd veleta camera

Manufactured by EMSIS
Sourced in Germany

The 2K CCD Veleta camera is a high-resolution digital imaging device capable of capturing detailed images. It features a 2048 x 2048 pixel CCD sensor that provides a resolution of 4 megapixels. The camera is designed for laboratory and scientific applications that require precise and accurate image capture.

Automatically generated - may contain errors

2 protocols using 2k ccd veleta camera

1

Optimized TEM Protocol for Mouse Skin

Check if the same lab product or an alternative is used in the 5 most similar protocols
For transmission electron microscopy work, mouse skin tissue samples were cut to a minimal size (1 mm x 1mm) and fixed with 2 % glutaraldehyde/2 % paraformaldehyde in 0.1M cacodylate buffer, pH 7.4. Further processing was done according using standard protocols, including a number of optimized steps for skin tissue, as described previously40 (link). Resulting 60 nm ultrathin sections were analysed with a Tecnai 12-biotwin transmission electron microscope (ThermoFisher) and representative images were taken with a 2K CCD Veleta camera (EMSIS, Münster, Germany).
+ Open protocol
+ Expand
2

Ultrastructural Tissue Fixation and Imaging

Check if the same lab product or an alternative is used in the 5 most similar protocols
Embryos were fixed in 2% PFA, 2% glutaraldehyde in 0.1M cacodylate buffer, pH 7.4. Samples were embedded in 2% LMP-agarose and postfixed in 1% osmium tetroxide, 1.5% potassium ferrocyanide in 0.1M cacodylate buffer. After that, the samples were dehydrated stepwise in ethanol, including en bloc 0.5% uranyl acetate staining during 70% ethanol. The last dehydration step was performed in propylene oxide followed by epon embedding. The samples were sectioned stepwise on an ultramicrotome (UC6, Leica) until the region of interest and 60-nm ultrathin sections were collected on a formvar-coated one-slot grid and counterstained with lead. The samples were imaged on a FEI-Tecnai 12-electron microscope at 80 kV (Thermo Fisher Scientific), and characteristic images were taken with a 2 K CCD-Veleta camera (EMSIS).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!