The largest database of trusted experimental protocols

Dp modular analytics

Manufactured by Roche

The DP Modular Analytics is a comprehensive, automated laboratory solution for clinical chemistry and immunochemistry testing. It offers reliable and precise analytical capabilities to support diagnostic workflows in healthcare settings.

Automatically generated - may contain errors

2 protocols using dp modular analytics

1

Detailed Biochemical Profiling in PCOS

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma glucose, TC, TGs, HDL-C, and LDL-C were measured by appropriate enzymatic methods on the DP Modular Analytics (Roche Diagnostics). Fasting insulin and SHBG were measured using Immulite 1000 Analyzer (Siemens Healthcare Diagnostics). Serum LH, FSH, total estradiol, and total testosterone levels were measured by electro-chemiluminescent immunoassays on the Roche E170 system (Roche Diagnostics). Serum total testosterone at follow-up was measured by the liquid chromatography tandem mass spectrometry (LC-MS/MS) method (Waters Quattro Micro) [13 ]. Based on the results of 170 archived samples from women with PCOS measured using both platforms and on the Passing and Bablok regression analysis conducted [13 ], a conversion calculation was performed on the follow-up testosterone levels to facilitate a comparison between the baseline and follow-up total testosterone results. AMH was measured using Elecsys AMH electro-chemiluminescent immunoassay Roche Cobas E411 analyzer (Roche Diagnostics). These measurements were performed using standard reagent kits supplied by the manufacturers. The analytical performance of these assays was within the specifications of the analysers.
+ Open protocol
+ Expand
2

Comprehensive Metabolic and Hormonal Profile

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma glucose, TC, TG, LDL-C, and HDL-C concentration were measured by DP Modular Analytics (Roche Diagnostics Corp.). Serum levels of luteinizing hormone (LH), follicle-stimulating hormone (FSH), total oestradiol, and total testosterone levels were measured by electrochemiluminescent immunoassays on the Roche E170 system (Roche Diagnostics Corp.). SHBG was measured using Immulite 1000 Analyser (Siemens Healthcare Diagnostics Inc.). Free androgen index was calculated by 100 × (total testosterone (nmol)/, SHBG (nmol)). AMH was measured using Elecsys® AMH electro-chemiluminescent immunoassay Roche Cobas E411 analyser (Roche Diagnostics Corp.). Insulin levels in the PCOS group were tested using an automated chemiluminescent immunoassay analyser (Siemens Healthcare Diagnostics Inc.), while ELISA kits (Dako Denmark A/S) were used to measure the insulin levels of the control group). The levels of FGF19, FGF21, and lipocalin-2 were measured by the corresponding ELISA kits (Antibody and Immunoassay Services, Hong Kong). These measurements were performed using standard reagent kits supplied by the manufacturers. The analytical performance of these assays was within the specifications of the analysers.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!