Prepstar sd 1 hplc system

Manufactured by Phenomenex

The Prepstar SD-1 HPLC system is a compact and reliable high-performance liquid chromatography (HPLC) instrument designed for versatile analytical applications. The system features a robust pump, an auto-sampler, and a UV-Vis detector, providing a complete solution for liquid chromatographic analysis.

Automatically generated - may contain errors

12 protocols using prepstar sd 1 hplc system

1

Synthesis and Characterization of Novel Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All commercial chemicals were used as supplied unless otherwise indicated. Flash chromatography was performed on a Teledyne Combiflash RF-200 with RediSep columns (silica) and indicated mobile phase. All moisture sensitive reactions were performed under an inert atmosphere of ultrapure argon with oven-dried glassware. 1H and 13C NMR spectra were recorded on a Varian 600 MHz and Bruker 400 spectrometer. Mass data were acquired on an Agilent TOF II TOS/MS spectrometer capable of ESI and APCI ion sources. Analysis of sample purity was performed on a Varian Prepstar SD-1 HPLC system with a Phenomenex Gemini, 5 μm C18 column (250 mm × 4.6 mm). HPLC conditions: solvent A = H2O, solvent B = MeCN; flow rate = 1.0 mL/min; compounds were eluted with a gradient of 5% MeCN/H2O for 0–5 min and to 95% MeCN/H2O from 5 to 30 min followed by 100% MeCN from 35 to 40 min. Purity was determined by total absorbance at 254 nm. The melting points (m.p.) were determined using an electro thermal Mel-Temp capillary melting point apparatus. All tested compounds have a purity ≥98%.
+ Open protocol
+ Expand
2

Synthesis of Deazaflavin Analogues

Check if the same lab product or an alternative is used in the 5 most similar protocols
All commercial chemicals were used as supplied unless otherwise indicated. Flash chromatography was performed on a Teledyne Combiflash RF-200 with RediSep columns (silica) and indicated mobile phase. All moisture sensitive reactions were performed under an inert atmosphere of ultrapure argon with oven-dried glassware. 1H and 13C NMR spectra were recorded on a Varian 600 MHz or Bruker 400 spectrometer. Mass data were acquired on an Agilent 6230 TOF LC/MS spectrometer capable of ESI and APCI ion sources. Analysis of sample purity was performed on a Varian Prepstar SD-1 HPLC system with a Phenomenex Gemini, 5 μm C18 column (250 mm × 4.6 mm). HPLC conditions: solvent A = H2O, solvent B = MeCN; flow rate = 1.0 mL/min; compounds were eluted with a gradient of 20% MeCN/H2O to 100% MeCN for 30 min. Purity was determined by total absorbance at 254 nm. All tested compounds have a purity ≥ 97%.
Deazaflavin analogues (4a-d) were reported earlier by Raoof et al.15 (link)
+ Open protocol
+ Expand
3

Anhydrous Solvent Purification and Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
All commercial chemicals were used as
supplied unless otherwise indicated. Dry solvents were either purchased
(toluene and dioxane) or dispensed under argon from an anhydrous solvent
system with two packed columns of neutral alumina or molecular sieves
(THF and DMF). Flash chromatography was performed on a Teledyne Combiflash
RF-200 with RediSep columns (silica) and indicated mobile phase. All
moisture sensitive reactions were performed under an inert atmosphere
of ultrapure argon with oven-dried glassware. 1H and 13C NMR spectra were recorded on a Varian 600 MHz spectrometer.
Mass data were acquired on an Agilent TOF II TOS/MS spectrometer capable
of ESI and APCI ion sources. Analysis of sample purity was performed
on a Varian Prepstar SD-1 HPLC system with a Phenomenex Gemini, 5
μm C18 column (250 mm × 4.6 mm). HPLC conditions: solvent
A = H2O, solvent B = MeCN; flow rate = 1.0 mL/min; compounds
were eluted with a gradient of 5% MeCN/H2O to 100% MeCN
for 25 min. Purity was determined by total absorbance at 254 nm. All
tested compounds have a purity ≥96.
+ Open protocol
+ Expand
4

Microwave-Assisted Organic Synthesis Protocols

Check if the same lab product or an alternative is used in the 5 most similar protocols
All commercial chemicals were used as supplied unless otherwise indicated. Microwave synthesis was performed with a Biotage Initiator Microwave Synthesizer. Flash chromatography was performed on a Teledyne Combiflash RF-200 with RediSep columns (silica) and indicated mobile phase. All moisture sensitive reactions were performed under an inert atmosphere of ultra-pure argon with oven-dried glassware. 1H and 13C NMR spectra were recorded on a Varian 600 MHz or Bruker 400 spectrometer. Mass data were acquired using an Agilent 6230 TOF LC/MS spectrometer. All NMR and mass spectrometers are located in the shared instrument rooms at the Center for Drug Design, University of Minnesota. Analysis of sample purity was performed on a Agilent Varian Prepstar SD-1 HPLC system located in our own lab with a Phenomenex Gemini, 5 ¼m C18 column (250mm × 4.6 mm). HPLC conditions: solvent A: H2O with 0.1% TFA; solvent B: MeCN; flow rate 1.0 mL/min; compounds were eluted with a gradient of 20% MeCN/H2O with 0.1% TFA to 100% MeCN for 20 min. All tested compounds have a purity ≥ 97%.
+ Open protocol
+ Expand
5

Preparation and Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All commercial chemicals were used as supplied unless otherwise indicated. Dry solvents were either purchased (toluene and MeOH) or dispensed under argon from an anhydrous solvent system with two packed columns of neutral alumina or molecular sieves. Flash chromatography was performed on a Teledyne Combiflash RF-200 with RediSep columns (silica) and indicated mobile phase. All moisture sensitive reactions were performed under an inert atmosphere of ultrapure argon with oven-dried glassware. 1H and 13C NMR spectra were recorded on a Varian 600 MHz spectrometer. Mass data were acquired on an Agilent TOF II TOS/MS spectrometer capable of ESI and APCI ion sources. Analysis of sample purity was performed on a Varian Prepstar SD-1 HPLC system with a Phenomenex Gemini, 5 μm C18 column (250 mm × 4.6 mm). HPLC conditions: solvent A = H2O, solvent B = MeCN; flow rate = 1.0 mL/min; compounds were eluted with a gradient of 20% MeCN/H2O for 5 min then to 100% MeCN for 40 min. Purity was determined by total absorbance at 254 nm. All tested compounds have a purity ≥96.
+ Open protocol
+ Expand
6

Purification and Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All commercial chemicals were used as supplied unless otherwise indicated. Dry solvents were either purchased (toluene and MeOH) or dispensed under argon from an anhydrous solvent system with two packed columns of neutral alumina or molecular sieves. Flash chromatography was performed on a Teledyne Combiflash RF-200 with RediSep columns (silica) and indicated mobile phase. All moisture sensitive reactions were performed under an inert atmosphere of ultra-pure argon with oven-dried glassware. 1H and 13C NMR spectra were recorded on a Varian 600 MHz spectrometer. Mass data were acquired on an Agilent TOF II TOS/MS spectrometer capable of ESI and APCI ion sources. Analysis of sample purity was performed on a Varian Prepstar SD-1 HPLC system with a Phenomenex Gemini, 5 micron C18 column (250mm × 4.6 mm). HPLC conditions: solvent A = H2O containing 0.1% TFA, solvent B = MeCN; flow rate = 1.0 mL/min; compounds were eluted with a gradient of 20% MeCN/H2O to 100% MeCN for 30 min. Purity was determined by total absorbance at 254 nm. All tested compounds have a purity ≥ 95%.
+ Open protocol
+ Expand
7

Purification and Characterization of Synthetic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All commercial chemicals were used as supplied unless otherwise indicated. Flash chromatography was performed on a Teledyne Combiflash RF-200 with RediSep columns (silica). All moisture sensitive reactions were performed under an inert atmosphere of ultra-pure argon with oven-dried glassware. 1H and 13C NMR spectra were recorded on a Varian 600 MHz spectrometer. Mass data were acquired using an Agilent 6230 TOF LC/MS spectrometer. Analysis of sample purity was performed on a Varian Prepstar SD-1 HPLC system with a Phenomenex Gemini, 5 µm C18 column (250mm × 4.6 mm). HPLC conditions: solvent A: H2O with 0.1% TFA; solvent B: MeCN; flow rate 1.0 mL/min; compounds were eluted with a gradient of 20% MeCN/H2O with 0.1% TFA to 100% MeCN for 20 min. All tested compounds have a purity ≥ 95%.
+ Open protocol
+ Expand
8

Purification and Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All commercial chemicals were used as supplied unless otherwise indicated. Flash chromatography was performed on a Teledyne Combiflash RF-200 with RediSep columns (silica) and indicated mobile phase. All moisture sensitive reactions were performed under an inert atmosphere of ultrapure argon with oven-dried glassware. 1H and 13C NMR spectra were recorded on a Varian 600 MHz spectrometer. Mass data were acquired on an Agilent TOF II TOS/MS spectrometer capable of ESI and APCI ion sources. Analysis of sample purity was performed on a Varian Prepstar SD-1 HPLC system with a Phenomenex Gemini, 5 μm C18 column (250 mm × 4.6 mm). HPLC conditions: solvent A = H2O, solvent B = MeCN; flow rate =1.0 mL/min; compounds were eluted with a gradient of 10% MeCN/H2O for 0–5 min and to 80% MeCN/H2O from 5 to 30 min followed by 100% MeCN from 30 to 35 min and then 10% MeCN/H2O from 35 to 40 min. Purity was determined by total absorbance at 254 nm. All tested compounds have a purity ≥98%.
+ Open protocol
+ Expand
9

General Analytical Procedures

Check if the same lab product or an alternative is used in the 5 most similar protocols
General Procedures. All commercial chemicals were used as supplied unless otherwise indicated. Flash chromatography was performed on a Teledyne CombiFlash RF-200 with RediSep columns (silica) and indicated mobile phase. All moisture sensitive reactions were performed under an inert atmosphere of ultra-pure argon with oven-dried glassware. 1H and 13C NMR spectra were recorded on a Varian 600 MHz spectrometer. Mass data were acquired using an Agilent 6230 TOF LC/MS spectrometer. Melting points were determined in open glass capillaries using a MEL-TEMP melting-point apparatus. Analysis of sample purity was performed on a Varian Prepstar SD-1 HPLC system with a Phenomenex Gemini, 5 μm C18 column (250mm × 4.6 mm). HPLC conditions: solvent A: H2O with 0.1% TFA; solvent B: MeCN; flow rate 1.0 mL/min; compounds were eluted with a gradient of 20% MeCN/H2O with 0.1% TFA to 100% MeCN for 20 min. All tested compounds have a purity ≥ 97%.
+ Open protocol
+ Expand
10

Synthetic Workflow for Purified Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All commercial chemicals were used as supplied unless otherwise indicated. Dry solvents were either purchased (toluene and dioxane, EtOH) or dispensed under argon from an anhydrous solvent system with two packed columns of neutral alumina or molecular sieves. Flash chromatography was performed on a Teledyne Combiflash RF-200 with RediSep columns (silica) and indicated mobile phase. All moisture sensitive reactions were performed under an inert atmosphere of ultra-pure argon with oven-dried glassware. 1H and 13C NMR spectra were recorded on a Varian 600 MHz spectrometer or Bruker 400 MHz spectrometer. Mass data were acquired on an Agilent TOF II TOS/MS spectrometer capable of ESI and APCI ion sources. Melting points were determined in open glass capillaries using a MEL-TEMP melting-point apparatus. Analysis of sample purity was performed on a Varian Prepstar SD-1 HPLC system with a Phenomenex Gemini, 5 micron C18 column (250mm x 4.6 mm). HPLC conditions: solvent A = H2O, solvent B = MeCN; flow rate = 1.0 mL/min; compounds were eluted with a gradient of 20% MeCN/H2O to 100% MeCN for 30 min. Purity was determined by total absorbance at 254 nm. All tested compounds have a purity ≥ 96%. Characterization data for final compounds other than the representative analogues are shown in Supplementary Data.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!