The largest database of trusted experimental protocols

20 protocols using resistin

1

ELISA for Mouse TNF-α and Resistin

Check if the same lab product or an alternative is used in the 5 most similar protocols
Mouse TNF-α(R&D Systems, Inc) and resistin (R&D Systems, Inc) ELISA kits were used to assay secreted TNF-α and resistin from mouse serum and supernatant fluid from adipocytes. Assays were performed as per the manufacturer’s protocol. All samples were evaluated in triplicate. Intra-assay precision variability was <4% and 5.8% respectively.
+ Open protocol
+ Expand
2

Hormones and Adipokines in Breast Health

Check if the same lab product or an alternative is used in the 5 most similar protocols
Serum prolactin (PRL), estradiol (E2), and progesterone were determined by ECLIA (Roche Diagnostic GmbH, Mannheim, Germany) with a lower limit of sensitivity <0.05 ng/mL, <5 pg/mL, and 0.03 ng/mL, respectively, and interassay coefficients of variations were <4.0%, <4.6%, and <2.4%, respectively.
ELISA method was used for measurements of plasma and breast cyst fluids leptin (TECOmedical AG, Sissach, Switzerland), adiponectin (TECOmedical AG, Sissach, Switzerland), resistin (R&D, Minneapolis, MN, USA), visfatin/NAPMT (BioVendor, Brno, The Czech Republic), TNF-α (R&D, Minneapolis, MN, USA), IL-6 (R&D, Minneapolis, MN, USA), with the lower limit of sensitivity of 0.2 ng/mL, 0.06 μg/mL, 0.05 ng/mL, 0.03 ng/mL, 0.19 pg/mL, and 0.1 pg/mL, respectively; intra- and interassay coefficients of variations were <6.8% and <7.7% for leptin, <4.7% and <6.7% for adiponectin, <5.5% and <9.2% for resistin, <9.1% and <5.6% for visfatin/NAPMT, <8.7% and 10.4% for TNF-α, and <7.8% and 9.6% for IL-6.
+ Open protocol
+ Expand
3

Neutrophil Function in Hyperresistinemia

Check if the same lab product or an alternative is used in the 5 most similar protocols
We used neutrophilic-differentiated NB4 cells (NB4PMN) to study the effect of hyperresistinemia on neutrophil function in a standard and reproducible way. Neutrophilic differentiation was achieved by previously described methods [10 (link)]. Briefly, NB4 cells were treated with 1 μM all-trans retinoic acid (ATRA) for 6 days in culture media. Successful neutrophilic differentiation was assessed using CD11b, CD35, and CD71 surface markers (BD Biosciences) with flow cytometry. For some experiments, NB4PMN were incubated for 1 h in human control serum (Atlanta Biologicals Flowery Branch, GA, USA) spiked with different concentrations of recombinant human resistin (R&D Systems, Minneapolis, MN, USA) at 20, 50, 100 ng/mL to replicate normal circulating vs. septic resistin concentrations.
+ Open protocol
+ Expand
4

Fasting Blood Analysis in Mice

Check if the same lab product or an alternative is used in the 5 most similar protocols
Before the end of the study, at weeks six and twelve, the mice were fasted for six hours in the morning. Under isoflurane anesthesia, blood was collected via cardiac punction, and euthanasia was performed by cervical dislocation. Blood samples were incubated for 30 min at room temperature and centrifuged for 15 min at 1500× g, and the obtained serum was immediately frozen and stored at −80 °C. Serum cholesterol and triglyceride levels as well as alanine aminotransferase (ALT) activity were measured by fluorometric assays (Abcam, Cambridge, UK). Serum insulin (Mercodia Ltd., Uppsala, Sweden), serum amyloid A (SAA), leptin, resistin, adipsin, and adiponectin (R&D Systems Europe Ltd., Abingdon, UK) were measured by enzyme-linked immunoassays (ELISAs). The detection limits were 33 pmol/L for insulin, 62.5 ng/L for SAA, 7.8 ng/L for leptin and resistin, 375 ng/L for adipsin, and 15.6 ng/L for adiponectin.
+ Open protocol
+ Expand
5

Biomarkers of Metabolic Health

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood morphology and serum C-reactive protein (CRP) levels were assessed. CRP concentrations were assessed by an automated system (Modular PPE, Roche Diagnostics GmbH, Mannheim, Germany). The inter-assay coefficient of variability was 5.7%.
The ELISA method was used for measurements of plasma and fluids leptin (TECOmedical AG Sissach, Switzerland), adiponectin (TECOmedical AG Sissach, Switzerland), omentin (DRG Instruments GmbH, Marburg, Germany), RBP4 levels (Phoenix Pharmaceuticals, Burlingame, USA), resistin (R&D, Minneapolis, MN, USA), and visfatin/NAMPT (BioVendor, Brno, The Czech Republic) with the LoQ of 0.08 ng/mL, 0.11 ng/mL, 0.2 ng/mL, 0.6 ng/mL and 0.5 ng/mL, 2.17 ng/mL, 0.05 ng/mL, and 30 pg/mL respectively; intra- and inter-assay coefficients of variations were 4.6% and 7% for leptin, 5% and 6% for adiponectin, 3.7% and 4.6% for omentin-1, 5.0% and <14.0% for RBP4, <5.5% and <9.2% for resistin, and 5.6% and 5.9% for visfatin/NAMPT.
+ Open protocol
+ Expand
6

Biomarker Analysis in Fasting Participants

Check if the same lab product or an alternative is used in the 5 most similar protocols
Individuals had been fasting (12 hours) before their visit. Blood samples were retrieved and processed at a single center and stored at –80°C until use. Interleukin (IL)-6, IL-10 (Bender Medsystems, Burlingame, CA, USA), resistin, and soluble(s)CD14 (R&D Systems, Minneapolis, MN, USA) levels were analyzed using an enzyme-linked immunosorbent assay. Serum ultrasensitive C-reactive protein (us-CRP) was measured by immononephelometry on an IMMAGE analyzer (Beckman-Coulter, Miami, FL, USA). Plasma D-dimer was measured by enzyme-linked fluorescent assay on a VIDAS analyzer (Biomérieux, Marcy-l’Etoile, France). Inducible protein (IP)–10, fractalkine, Monokine induced by gamma interferon (MIG), monocyte chemoattractant protein (MCP)–1, E-selectin, and tumor necrosis factor (TNF)–α were quantified from plasma using the BD Cytometric Bead Array system (BD, Franklin Lakes, NJ, USA).
+ Open protocol
+ Expand
7

Biochemical Measurement of Adipokines and Insulin

Check if the same lab product or an alternative is used in the 5 most similar protocols
Commercially available enzyme-linked immunosorbent assay (ELISA) kits were used to perform the biochemical measurements of adipokines and insulin according to the manufacturer’s instructions (visfatin kit was from BioVision; chemerin, PAI-1, resistin, CCL-2, IL-6, IL-8, IL-10 and TNF-α kits were from R&D; leptin, adiponectin and insulin kits were from Thermo Fisher Scientific). The coefficient of variability (CV) for the ELISA kits were shown as follows: visfatin (intra-assay: 4.4–8%; inter-assay: 8.2%), chemerin (intra-assay: 3.9%; inter-assay: 7.3%), PAI-1 (intra-assay: 6.8%; inter-assay: 7%), resistin (intra-assay: 4.7%; inter-assay: 8.4%), CCL-2 (intra-assay: 5%; inter-assay: 5.1%), IL-6 (intra-assay: 2.6%; inter-assay: 4.5%), IL-8 (intra-assay: 4.7–6.7%; inter-assay: 5.8–7.7%), IL-10 (intra-assay: 3.7%; inter-assay: 6.9%), TNF-α (intra-assay: 4.9–7.8%; inter-assay: 4.7%-5.8%), leptin (intra-assay: 3.9%; inter-assay: 5.3%), adiponectin (intra-assay: 3.8%; inter-assay: 5.5%), and insulin (intra-assay: 4.8%-6%; inter-assay: 8.1% to 9%). All measurements were performed in duplicates or triplicates. Seven controls (one blank, two at lower concentrations, two at medium concentrations, and two at higher concentrations) were also quantified in duplicates to check for the reproducibility of measurements and confirm acceptable reproducibility.
+ Open protocol
+ Expand
8

Circulating Metabolic Biomarker Profiling

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood in the fed state was obtained by tail bleeding, and circulating factor concentrations were measured using the following kits according to the respective manufacturer's protocols: Bio-Plex protein array system (Biorad, UK) with one multiplex panel was used to measure total Glucagon-like peptide-1 (GLP-1), glucose-dependent insulinotropic polypeptide (GIP), leptin, adiponectin and plasminogen activator inhibitor-1 (PAI-1); one multiplex panel was used to measure fatty acid binding protein 4 (FABP4) and resistin (R&D Systems, UK); non-esterified fatty acid (NEFA) serum levels were measured by colorimetric assay (Randox, UK) and dipeptidyl peptidase 4 (DPP4; R&D Systems, UK) levels were measured by ELISA.
+ Open protocol
+ Expand
9

Quantifying Adipocytokine Levels in Fasting Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
We assessed 4 adipocytokines as potential mediators: IL-6, MCP-1, resistin, and adiponectin. Serum IL-6, MCP-1, resistin (R&D Systems), and adiponectin (Quantikine) were measured in duplicate by ELISA from fasting blood samples collected and stored at −80°C.(42 (link)) Intra-assay coefficients of variation (% CV) for are 3.1±2.2 (IL-6), 3.8±3.3 (MCP-1), 9.0±2.0 (resistin), and 5.8±0.6 (adiponectin).(43 (link)) Standard quality control evaluations were performed and all intra-assay coefficients of variation were <10%. The details of the assays and measurements have been described in previous studies.(42 (link), 44 (link))
+ Open protocol
+ Expand
10

Metabolic Biomarker Profiling in Mice

Check if the same lab product or an alternative is used in the 5 most similar protocols
Mice were fasted overnight and blood samples were collected from the chest cavity when the hearts were excised. Blood glucose was measured using an ACCU-CHEK Aviva glucometer (Roche, Indianapolis, IN). Commercial kits were used to measure plasma levels of insulin (ALPCO, Salem, NH), HMW & total adiponectin (ALPCO), resistin (R&D Systems, Minneapolis, MN), and visfatin (BioVision).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!