The largest database of trusted experimental protocols

Titan 80 300 stem

Manufactured by Ametek

The Titan 80/300 STEM is a scanning transmission electron microscope (STEM) designed and manufactured by Ametek. It is capable of operating at accelerating voltages of 80 kV and 300 kV. The Titan 80/300 STEM provides high-resolution imaging and analytical capabilities for materials science and nanotechnology research.

Automatically generated - may contain errors

2 protocols using titan 80 300 stem

1

Characterization of Aged Biochar Particles

Check if the same lab product or an alternative is used in the 5 most similar protocols
Forty biochar particles were extracted from each treatment and examined using a Zeiss Sigma SEM. Detailed analysis of five particles was carried out using a Bruker X-ray Dispersive analyzer (EDS). A Cs-corrected FEI Titan 80/300 STEM, working at 80 keV and equipped with a Gatan imaging filter Tridiem and an EDS analyzer, was used to determine the structure and composition of the organo-mineral clusters that had accumulated on the surface of the aged biochar. Twenty biochar particles were sonicated in ethanol and a sample placed on a lacey carbon grind35 (link). Detailed examination of two clusters was carried out using EELS and EDS35 (link).
+ Open protocol
+ Expand
2

Synthesis and Characterization of CdTe Quantum Dots

Check if the same lab product or an alternative is used in the 5 most similar protocols
Into a 35 mL microwave vessel with a stir bar, 48.5 mg CdCl2, 100 mg sodium citrate dehydrate, 26 μL of MPA and 25 mL Millipore water were combined. The pH of this mixture was brought to 10.5 using 1 M NaOH, and then 11 mg of sodium tellurite and 18.9 mg of sodium borohydride were added. The vessel was capped and placed in a CEM Discover SP microwave synthesizer. The mixture was microwaved in Dynamic Mode at 100 °C, 250 psi, 300 W power, and high stirring for 10 min. QDs were purified three times via centrifugation through a 30K MWCO centrifuge filter at 2000g for 5 min, and finally redispersed in pH 10.5 Millipore water. Absorbance properties were detected with a Thermo Scientific Evolution 201 UV–Vis spectrophotometer. The absorbance was used to determine QDs’ molar concentration and size according to the literature.30 Fluorescence spectroscopy measurements were collected using a PTI-Horiba QuantaMaster 400 fluorimeter. High-resolution transmission electron microscopy (HRTEM) images of QDs, that were drop-coated onto mesh copper grids with ultrathin carbon film on holey carbon support film (Ted Pella, Inc.), were obtained using a Titan 80–300 S/TEM, operating at 300 kV with a Gatan OneView imaging camera. Dynamic Light Scattering (DLS) measurements of MPA–QDs were performed using a Malvern Zetasizer Nano ZS instrument.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!