The largest database of trusted experimental protocols

3 protocols using 3h dihydroalprenolol

1

Radioligand Binding Assay for β2AR

Check if the same lab product or an alternative is used in the 5 most similar protocols
HEK-β2AR were pelleted by centrifugation at 1,000 x g for 10 minutes. Cells were re-suspended in assay buffer (7.5 mM Tris-HCl and 5 mM EDTA, pH 7.0) and homogenized 20 times. Membranes were pelleted via centrifugation at 40,000 x g for 30 minutes at 4 °C and re-suspended in assay buffer at 1 µg/µl protein with DC Protein Assay (BioRad Laboratories, Hercules CA). For competition binding assays, 50 µg of membrane was incubated with 0.8 nM of [3H]-Dihydroalprenolol (Perkin Elmer, Waltham, MA) and varying concentrations of isoproterenol in the presence or absence of 100 µM H2O2 and/or 1 mM dimedone. Non-specific binding was determined as the amount of radioligand bound in the presence of 10 μM propranolol. 4 mM magnesium chloride was added to the binding buffer to elucidate the effects of divalent cations. CALU3 membranes were prepared in the same manner in 25 mM HEPES with 5 mM EDTA (pH 7.0). Saturation isotherms were used to quantify the maximal binding (Bmax) using approximately 100 µg of protein and a saturating concentration of [3H]-Dihydroalprenolol (10 nM) with or without 1 mM H2O2 and/or 1 mM dimedone, as noted in the figure legends. All reactions were incubated for 30 minutes at room temperature with agitation and terminated by rapid filtration over Whatman filters, washed with iced assay buffer supplemented with 0.1% BSA and assessed by liquid scintillation counting.
+ Open protocol
+ Expand
2

Fluorescent Probe Assay Reagents

Check if the same lab product or an alternative is used in the 5 most similar protocols
DYn-2 (250 mM in DMSO) was from Kerafast (Boston, MA). CM-H2DCFDA (10 µM prepared fresh in DMSO) was from Thermo Fisher (Waltham, MA). Biotin-azide (5 mM in DMSO) was from Cayman Chemical (Ann Arbor, MI). FITC conjugated anti-mouse antibody was from Rockland Immunochemicals (Limerick, PA). [3H]-Dihydroalprenolol was purchased from Perkin Elmer (Waltham, MA). All other reagents were purchased from Sigma-Aldrich or VWR at their highest available purities.
+ Open protocol
+ Expand
3

β-Adrenoceptor Activation Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
Isoproterenol, forskolin, ICI 118-551 (ICI), epinephrine, norepinephrine, salbutamol, salmeterol, ritodrine, fenoterol, alprenolol, glucagon, oxyntomodulin, GLP-1-(7-36), rolipram, zaprinast, caffeine, HEPES, IBMX, magnesium and calcium chloride, bovine serum albumin (BSA), and Whatman glass microfiber filters (grade GF/B) were purchased from Sigma-Aldrich (Broendby, Denmark). Dulbecco's modified Eagle's medium (DMEM), Hank's balanced salt solution (HBSS), fetal bovine serum (FBS), zeocin, geneticin G418, and penicillin/streptomycin were purchased from Invitrogen (Naerum, Denmark). Black 384-well plates were purchased from Greiner Bio-One (Kremsmünster, Austria). [ 3 H] dihydroalprenolol and EnVision Xcite multilabel plate reader were from PerkinElmer (Waltham, MA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!