The largest database of trusted experimental protocols

Masstrak amino acid analysis solution aaa kit

Manufactured by Waters Corporation
Sourced in United States

The MassTrak Amino Acid Analysis Solution (AAA) kit is a laboratory equipment product from Waters Corporation. It is designed for the analysis and quantification of amino acids in various sample types. The core function of this kit is to enable precise and accurate measurement of amino acid concentrations using liquid chromatography-mass spectrometry (LC-MS) technology.

Automatically generated - may contain errors

2 protocols using masstrak amino acid analysis solution aaa kit

1

Quantitative Serum Amino Acid Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
The metabolomics method for analyzing these serum samples using LC-MS/MS has been described previously28 (link). Briefly, serum amino acid calibration standards were prepared with a MassTrak Amino Acid Analysis Solution (AAA) kit (Waters Corp, Milford, MA) according to instructions with slight modifications for detection on a mass spectrometer40 (link). To measure accurate metabolite concentrations, we first normalized each sample to the internal standard. Serum samples of 10 μl were spiked with an internal standard then derivatized according to MassTrak instructions. The amino acid derivatizing reagent used was 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate. Then, concentrations based on the standard curve were determined. A 10-point standard concentration curve was made from the calibration standard solution to calculate amino acid concentrations in serum samples. High resolution separation was done using an Acquity UPLC system and injecting 1 ml of derviatized solution, with a UPLC BEH C18 column (Waters Corp, Milford, MA). Mass detection was completed on a TSQ Ultra Quantum running in ESI positive mode (Thermo Scientific, Waltham, MA).
+ Open protocol
+ Expand
2

Serum Amino Acid Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
Serum amino-acid calibration standards were prepared with MassTrak Amino Acid Analysis Solution (AAA) kit from Waters (Milford, MA, USA) according to instructions with slight modifications for detection on a mass spectrometer.33 (link) A 10-point standard concentration curve was made from the calibration standard solution to calculate amino-acid concentrations in serum samples. Serum samples of 10 μl were spiked with an internal standard then derivatized according to MassTrak instructions. The amino-acid-derivatizing reagent used was 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate. High-resolution separation was done using an Acquity UPLC system and injecting 1 ml of derviatized solution, with a UPLC BEH C18 column (Milford, MA, USA). Mass detection was completed on a TSQ Ultra Quantum running in ESI-positive mode (Thermo Scientific, Waltham, MA, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!