The largest database of trusted experimental protocols

9 protocols using senkirkine

1

Comprehensive Pyrrolizidine Alkaloid Standard Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
In total, 30 pyrrolizidine alkaloid standards were utilized in a high resolution accurate mass (HRAM) LC-MS/MS screen. Echimidine, erucifoline, europine, heliotrine, indicine, intermedine, jacobine, lasiocarpine lycopsamine, monocrotaline, retrorsine senecionine, seneciphylline, senecivernine, and their respective N-oxides, were purchased together with senkirkine and trichodesmine from Phytolab GmbH & Co. KG (Vestenbergsgreuth, Germany) and had a purity >89%. All other chemicals and solvents were of analytical reagent or HPLC grade purity. Water used for sample preparation and HPLC was Milli-Q purified (Merck Millipore, Darmstadt, Germany).
+ Open protocol
+ Expand
2

Analytical Characterization of Pyrrolizidine Alkaloids

Check if the same lab product or an alternative is used in the 5 most similar protocols
Lasiocarpine (Las) and lasiocarpine N-oxide were ordered from Cfm Oskar Tropitzsch (Marktredwitz, Germany). Lycopsamine (Lyc), Lycopsamine N-oxide, europine (Eur), europine N-oxide, senecionine (Sen), senecionine N-oxide, echimidine (Ech), echimidine N-oxide, intermedine, intermedine N-oxide, jacobine, jacobine N-oxide, heliosupine, heliosupine N-oxide, retrorsine N-oxide, retronecine, and senkirkine were obtained from Phytolab (Vestenbergsgreuth, Germany). Retrorsine (Ret) was delivered by AppliChem (Darmstadt, Germany). Methanol (MeOH, LC–MS grade) and water (H2O, LC–MS grade) were purchased from Merck KGA (Darmstadt, Germany). 7,9-Diglutathionyl-6,7-dihydro-1-hydroymethyl-5H-pyrrolizidine was obtained from ASCA (Berlin, Germany). Potassium cyanide (KCN), isotopically labeled potassium cyanide (KCX, K13C15N), glutathione and isotopically labeled glutathione (GSX, 13C215N-GSH), and all other chemicals and co-factors were purchased from Sigma-Aldrich (Steinheim, Germany). All chemicals were obtained in analytical grade, if available. Human liver microsomes (mixed gender from 50 donors; protein concentration 20 mg/mL; cytochrome P450 content 310 pmol/mg protein) and rat liver microsomes (male Sprague–Dawley rats; protein concentration 20 mg/mL; cytochrome P450 content 700 pmol/mg protein) were obtained from Corning (Corning, USA).
+ Open protocol
+ Expand
3

Extraction and Preparation of Pyrrolizidine Alkaloids

Check if the same lab product or an alternative is used in the 5 most similar protocols
Echimidine (94% purity), heliotrine (91% purity), lasiocarpine (98% purity), senecionine (99% purity) and senkirkine (98% purity) were purchased from PhytoLab (Verstenbergsgreuth, Germany). Platyphylline (95% purity) was purchased from BOC Sciences (New York, New York, USA). senecionine was dissolved in 0.2-M hydrochloric acid. Afterwards, pH was adjusted to 6–7 using 0.2-M sodium hydroxide solution. Sodium chloride (NaCl) was added to obtain a solution containing 0.15-M NaCl. All other PA were dissolved in 0.15-M aqueous NaCl solution.
+ Open protocol
+ Expand
4

Comprehensive Analytical Standards for Pyrrolizidine Alkaloids

Check if the same lab product or an alternative is used in the 5 most similar protocols
Analytical standards of all pyrrolizidine alkaloids and their N-oxide were purchased from Phytolab (Vestenbergsgreuth, Germany): Echimidine (Em), Echimidine-N-oxide (EmNO), Echinatine (En), Echinatine-N-oxide (EnNO), Erucifoline-N-oxide (ErNO), Europine (Eu), Europine-N-oxide (EuNO), Heliosupine (Hs), Heliosupine-N-oxide (HsNO), Heliotrine (Ht), Heliotrine-N-oxide (HtNO), Indicine (Id), Indicine-N-oxide (IdNO), Integerrimine (Ir), Integerrimine-N-oxide (IrNO), Intermedine (Im), Intermedine-N-oxide (ImNO), Lasiocarpine (Lc), Lycopsamine (Ly), Lycopsamine-N-oxide (LyNO), Retrorsine (Rt), Retrorsine-N-oxide (RtNO), Rinderine (Rn), Rinderine-N-oxide (RnNO), Senecionine (Sn), Senecionine-N-oxide (SnNO), Seneciphylline (Sp), Seneciphylline-N-oxide (SpNO), Senecivernine (Sv), Senecivernine-N-oxide (SvNO), Senkirkine (Sk), Spartioidine (St), Spartioidine-N-oxide (StNO), Usaramine (Us) and Usaramine-N-oxide (UsNO). Methanol (LC-MS grade) was from VWR Chemicals (Rosny-sous-Bois-cedex, France), sulphuric acid (96%) and acetonitrile (LC-MS grade) were from Carlo Erba Reagents (Val de Reuil Cedex, France), formic acid was from Carlo Erba Reagents (Milan, Italy) and ammonium formate (analytical grade) was from Sigma-Aldrich (St. Louis, MO, USA). Ultrapure water used throughout the experiments was produced by an EvoQua Water Technologies system (Diessechem, Milan, Italy).
+ Open protocol
+ Expand
5

Structural Diversity of Pyrrolizidine Alkaloids

Check if the same lab product or an alternative is used in the 5 most similar protocols
The structurally different PAs echimidine (94% purity), heliotrine (91% purity), lasiocarpine (98% purity), senecionine (99% purity), and senkirkine (98% purity) were purchased from PhytoLab (Verstenbergsgreuth, Germany). Platyphylline (95% purity) was purchased from BOC Sciences (New York, USA). PAs were dissolved in 0.15 M NaCl. Due to the poorer solubility, senecionine was first dissolved in 0.2 M hydrochloric acid, then the pH was adjusted to 6–7 and afterwards NaCl was added to a final concentration of 0.15 M.
+ Open protocol
+ Expand
6

Isolation and Characterization of Pyrrolizidine Alkaloids

Check if the same lab product or an alternative is used in the 5 most similar protocols
Intermedine (Im), senecionine (Sc), and senkirkine (Sk) were purchased from PhytoLab (Vestenbergsgreuth, Germany) the purity being specified as 97, 100, and 97%. Lasiocarpine (Lc) was obtained from Cfm Oskar Tropitzsch (Marktredwitz, Germany) with 98% purity. Methanol (MeOH, LC–MS grade) was purchased from Merck KGaA (Darmstadt, Germany). All other chemicals and co-factors were purchased from Carl Roth (Karlsruhe, Germany) or Sigma-Aldrich (Steinheim, Germany) at the highest purity available.
+ Open protocol
+ Expand
7

Procurement and Storage of Pyrrolizidine Alkaloids

Check if the same lab product or an alternative is used in the 5 most similar protocols
Lasiocarpine (CAS# 303–34-4), riddelliine (CAS# 23246–96-0), and senkirkine (CAS# 2318–18-5) were purchased from PhytoLab GmbH & Co. KG (Vestenbergsgreuth, Germany). DHP (6,7-dihydro-7-hydroxy-1-hydroxymethyl-5H-pyrrolizine) standard was kindly provided by Dr. Peter Fu at the National Center for Toxicological Research (Jefferson, AR). All chemicals were stored at −80°C and protected from light, as recommended by the vendor.
+ Open protocol
+ Expand
8

Sourcing of Research Chemicals

Check if the same lab product or an alternative is used in the 5 most similar protocols
Heliotrine was purchased from Latoxan SAS (Valence, France). Echimidine, senecionine, and senkirkine were purchased from PhytoLab GmbH & Co. KG (Vestenbergsgreuth, Germany). All other chemicals were purchased from Sigma-Aldrich (Taufkirchen, Germany) in the highest purity available.
+ Open protocol
+ Expand
9

Determination of Phytochemicals in Botanical Extracts

Check if the same lab product or an alternative is used in the 5 most similar protocols
All solvents, chemicals, and reagents used for determination of PAs, chelidonic acid, glycyrrhizic acid, and apigenin 7-glucoside were purchased from Carl Roth, Merck, or Sigma-Aldrich in MS grade. Chemicals and reagents applied for imprinting were purchased by Sigma and Merck in the highest purity available. Intermedine (purity > 99 % by HPLC), lycopsamine (purity > 99 % by HPLC), retrors-ine (purity > 99 % by HPLC), senecionine (purity > 99 % by HPLC), senecyphilline (purity > 99 % by HPLC), senkirkine (purity > 98 % by HPLC), erucifoline (purity > 98 % by HPLC), senecivernine (purity > 95 % by HPLC), erucifoline-N-oxide (purity > 95 % by HPLC), retrosine-N-oxide (purity > 99 % by HPLC), senecyphilline-N-oxide (purity > 99 % by HPLC), senecivernine-N-oxide (purity > 99 % by HPLC), and chelidonic acid (purity > 98 % by HPLC) used as reference standards for quantification were purchased in the highest purity available from Phytolab. apigenin 7-glucoside (purity > 94 % by HPLC) and glycyrrhizic acid (purity > 72 % by HPLC) were supplied by EDQM.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!