The largest database of trusted experimental protocols

Diff60 gradient unit

Manufactured by Bruker

The Diff60 gradient unit is a laboratory equipment designed to generate and control magnetic field gradients. It is a core component in various analytical techniques that rely on the use of magnetic field gradients, such as diffusion-ordered spectroscopy (DOSY) and other magnetic resonance imaging (MRI) applications.

Automatically generated - may contain errors

2 protocols using diff60 gradient unit

1

NMR Diffusion Measurements in Ionic Liquids

Check if the same lab product or an alternative is used in the 5 most similar protocols
The NMR measurements on a Bruker Avance—III 400 MHz NMR spectrometer equipped with the diff60 gradient unit (the maximum field gradient amplitude was 30 T m−1) were carried out at the temperature 22 ± 1 °C. The NMR measurements of 1H (diffusion of solvent molecules EC and ionic liquid IL, EMI), 7Li (diffusion of lithium cations) and 19F (diffusion of anions BF4) were carried out with operating frequencies of 400, 155.5 and 376.5 MHz, respectively. The stimulated spin echo sequence was applied. The details of self-diffusion coefficient measurements are given in [31 (link),32 (link)]. The experimental NMR parameters of pulse sequences were the following: π/2 pulse was 9 μs (1H), 9 μs (7Li) and 10 μs (19F); gradient pulse duration time δ was 1.0 (1H), 1.0 (7Li) and 3.0 (19F) ms; diffusion time was 19.7 (1H), 19.7 (7Li) and 49.0 (19F) ms; repetition time 3 s; and the diffusion 32 steps with maximum field gradient amplitude g were 3.5 (1H), 11.5 (7Li) and 4.0 (19F) T m−1. The strength of the gradient changed linearly. The measurement error of the self-diffusion coefficients was 5%. The temperature dependences of the diffusion coefficients were measured at the temperature range from 22 to 60 °C.
+ Open protocol
+ Expand
2

NMR Diffusion Measurements of Ions and Solvent

Check if the same lab product or an alternative is used in the 5 most similar protocols
The NMR measurements on a Bruker Avance-III 400 MHz NMR spectrometer equipped with the diff60 gradient unit (the maximum field gradient amplitude was 30 T/m) were carried out at the temperature 22 ± 1 °C. The NMR measurements of 1H (diffusion of solvent molecules), 7Li (diffusion of lithium cations), and 19F (diffusion of anions) were carried out with operating frequencies of 400, 155.5, and 376.5 MHz, respectively. The stimulated spin-echo sequence was applied. The details of self-diffusion coefficient measurements are given in [61 (link),62 (link)]. The experimental NMR parameters of pulse sequences were the following: π/2 pulse was9.5 μs (1H), 9 μs (7Li), and 10 μs (19F); gradient pulse duration time δ was 1–1.5 ms; and the diffusion 32 steps with maximum field gradient amplitude g were 3.5 (1H), 11.5 (7Li), and 4.0 (19F) T/m. The measurement error of the self-diffusion coefficients was 5%.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!