The largest database of trusted experimental protocols

Softmax apparatus

Manufactured by Molecular Devices
Sourced in United States

The SoftMax apparatus is a piece of laboratory equipment designed for the measurement and analysis of microplate-based assays. It provides precise and reproducible optical density, absorbance, and fluorescence readings for a variety of biological and chemical applications.

Automatically generated - may contain errors

4 protocols using softmax apparatus

1

Cell Proliferation Assay Using MTT

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cell proliferation was analyzed using a MTT assay (Amresco, Shanghai, China). The cells were then seeded into 96-well plates (4 × 103 cells/well). At the appropriate time after transfection, 20 µL of MTT solution (5 mg/mL) was added to each well. After 3 h, media containing MTT solution were removed and 100 µL DMSO (Sigma-Aldrich, St. Louis, MO, USA) was added to each well. The absorbance at 540 nm was measured with a SoftMax apparatus (Molecular Devices, Sunnyvale, CA, USA). At least three independent experiments were performed to confirm the reproducibility of the results.
+ Open protocol
+ Expand
2

Cell Proliferation Analysis by MTT Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cell proliferation was analyzed by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay (Amresco, Shanghai, China). AGS-EBV, SNU-719, or DKK1 over-expressing AGS-EBV cells ( cells/well) were seeded into 96-well plates. After the indicated periods following transfection, 20 µl of MTT solution (5 mg/ml) was added to each well. The absorbance at 595 nm was measured with a SoftMax apparatus (Molecular Devices, Sunnyvale, CA, USA) 4 h after adding MTT solution.
+ Open protocol
+ Expand
3

MTT Assay for Cell Proliferation

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cell proliferation was assessed using a 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay (Cayman, Ann Arbor, MI, USA). The AGS and AGS-EBV cells (4 × 105 cells/well) were seeded into 96-well plates. After the indicated periods following transfection, 20 µL of MTT solution (5 mg/mL) was added to each well. The absorbance at 570 nm was measured with a SoftMax apparatus (Molecular Devices, San Jose, CA, USA) 4 h after adding MTT solution.
+ Open protocol
+ Expand
4

Cell Proliferation Analysis by MTT Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cell proliferation was analyzed by using a 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay (Amresco, Shanghai, China). AGS cells (3 x103) were seeded in 96-well plates. At a set time following transfection, 20 µl of MTT solution (5 mg/mL) was added to each well. After 4 h, the medium and MTT solution were removed. Then, 100 µl DMSO (Sigma-Aldrich, St. Louis, MO, USA) was added to each well. The absorbance at 595 nm was measured with SoftMax apparatus (Molecular Devices, Sunnyvale, CA, USA) 24 h after adding the DMSO.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!