The largest database of trusted experimental protocols

240 analyser

Manufactured by PerkinElmer
Sourced in United States

The 240 analyser is a laboratory instrument designed for the analysis of various samples. It is capable of performing high-precision measurements and data processing. The core function of the 240 analyser is to provide accurate and reliable analytical results.

Automatically generated - may contain errors

5 protocols using 240 analyser

1

Structural Characterization of Synthetic Compound

Check if the same lab product or an alternative is used in the 5 most similar protocols
The structure of a synthesised compound was confirmed by 1H-NMR and 13C-NMR spectra recorded on the Brucker AC 200F (Germany) apparatus (1H – 200 MHz and 13C – 50 MHz) in deuterated dimethylsulfoxide (d6-DMSO). Chemical shifts are expressed as a δ value (ppm). The multiplicity of resonance peaks is indicated as singlet (s), doublet (d), triplet (t), quartet (q), and multiplet (m). Infrared spectra were recorded on the Perkin-Elmer Spectrum 100 FT-IR spectrometer (PerSeptive Biosystems, Houston, TX, USA) as KBr pellets (4000–450 cm−1). Mass spectra were recorded using a Mariner mass spectrometer (USA). Melting points were determined on the Buchi 535 (GER) melting-point apparatus, and were uncorrected. Elemental analysis of C, H, and N was performed on a Perkin-Elmer 240 analyser (USA), and satisfactory results within ±0.4% of calculated values were obtained.
+ Open protocol
+ Expand
2

Characterization of NSAID Thioester Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Melting points were recorded on a Barnstead 9100 Electrothermal melting apparatus. IR spectra (KBr) were recorded on an FT-IR Perkin-Elmer spectrometer (ν cm−1). 1H and 13C NMR spectra were recorded on Bruker 500 or 700 MHz spectrometers using DMSO-d6 or CDCl3 as the solvent. Microanalytical data (C, H and N) were obtained using a Perkin-Elmer 240 analyser and the proposed structures were within ±0.4% of the theoretical values. Mass spectra were recorded on a Varian TQ 320 GC/MS/MS mass spectrometer. NSAIDs thioester was obtained according to reported method43 .
+ Open protocol
+ Expand
3

Characterization of Compound 8 Crystal

Check if the same lab product or an alternative is used in the 5 most similar protocols
Melting points were recorded on a Barnstead 9100 electrothermal melting apparatus. IR spectra (KBr) were recorded on an FT-IR Perkin-Elmer spectrometer (ν cm−1). 1H and 13C NMR spectra were recorded on Bruker 500 or 700 MHz spectrometers using DMSO-d6 as the solvent. Microanalytical data (C, H, and N) were obtained using a Perkin-Elmer 240 analyser and the proposed structures were within ±0.4% of the theoretical values. Mass spectra were recorded on a Varian TQ 320 GC/MS/MS mass spectrometer. Data of compound 8 were collected on a Bruker APEX-II D8 Venture area diffractometer (Billerica, MA), equipped with graphite monochromatic Mo Kα radiation, λ = 0.71073 Å at 296 (2) K. Cell refinement and data reduction were carried out by Bruker SAINT. SHELXT35 ,36 was used to solve the structure.
+ Open protocol
+ Expand
4

Synthesis and Characterization of Co(II) Complex

Check if the same lab product or an alternative is used in the 5 most similar protocols
Complex 1 was synthesized as follows: H2L (212 mg, 0.80 mmol, 2 equiv.) and Co(BF4)2 6 H2O (136 mg, 0.40 mmol, 1 eqequiv.) were dissolved in acetonitrile (10 ml) and NEt3 (0.5 ml) was added. The reaction mixture was stirred at room temperature. Diffusion of diethylether into the acetonitrile solution yielded pink crystals (250 mg, 0.32 mmol, 80%) of the desired complex. Those were also suitable for X-ray analysis. Elem. Anal. Calc. for C28H50CoN6O8S4 0.15 H2O C 42.65; H 6.41; N 10.66% found C 42.66; H 6.75; N 10.63%. ESI-MS calc. for C16H23CoN4O8S4 (M – 2 HNEt3+3 H+): m/z 585.9731 found 585.9713.
Elemental analysis was performed on a Perkin Elmer Analyser 240. Mass spectrometry experiments were carried out on a Bruker Daltronics Mictrotof-Q mass spectrometer.
Single crystals of 1 were grown by the slow diffusion of diethylether into an acetonitrile solution. The X-ray diffraction measurement was performed on a BRUKER Smart AXS diffractometer (graphite-monochromated Mo Kα radiation, λ=0.71073 Å). SHELXS-97 and SHELXL-97 were used to solve and refine the structure49 . The CCDC deposition number is CCDC 971167.
+ Open protocol
+ Expand
5

Electrochemical and Spectroscopic Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cyclic voltammetry was carried out in 0.1 M Bu 4 NPF 6 solution using a three-electrode configuration (Pt or glassy carbon working electrode, Pt counter electrode, Ag wire as pseudoreference) and PAR Versa STAT 4 potentiostat. The ferrocene/ ferrocenium (Fc/Fc + ) couple served as an internal reference. UV-vis-NIR absorption spectra were recorded on an Avantes spectrometer system: Ava Light-DH-BAL (light source), AvaSpec-ULS2048 (UV-vis-detector) and AvaSpec-NIR256-2.5TEC (NIR-detector). Spectroelectrochemical measurements were carried out using an optically transparent thin layer electrochemical (OTTLE) cell. 17 Elemental analysis was performed on a Perkin Elmer Analyser 240. Mass spectrometry experiments were carried out on a Bruker Daltonics Mictrotof-Q mass spectrometer and mass spectrum simulations were done with mmass.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!