The largest database of trusted experimental protocols

5 protocols using hdac activity assay kit

1

Nuclear Protein HDAC1 Activity Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
Nuclear proteins were extracted with a Nuclear Extract Kit (Abcam). The HDAC1 activity was subsequently measured with an HDAC Activity Assay Kit (Epigentek, Farmingdale, NY, USA). All procedures were conducted according to the manufacturer's recommendations.
+ Open protocol
+ Expand
2

Quantifying HDAC Activity in FAPs

Check if the same lab product or an alternative is used in the 5 most similar protocols
HDAC activity in FAPs was measured by HDAC activity assay kit (Epigentek Inc., # P-4002–96). FAPs were collected with FACS and then lyzed with nuclear extract lysis buffer. The same amount of nuclear proteins from FAPs were was added into 96 well plates for HADC enzyme activity measurement by a Bio-rad plate reader (Bio-Rad Inc.) with 560 nm wavelength according to manufacture′s instruction.
+ Open protocol
+ Expand
3

Quantitative Proteomics of HDAC Inhibitors

Check if the same lab product or an alternative is used in the 5 most similar protocols
Romidepsin (S3020), Panobinostat (S1030), and Vorinostat (SAHA) (S1047) were purchased from Selleck Chemicals. Nuclear Extraction kit (40010) was purchased from Active Motif. HDAC Activity Assay kit (P-4034–96) was purchased from Epigentek. MTT assay kit was purchased from Abcam (ab211091). TMTpro 16plex Label Reagent set (A44522), trypsin, BCA assay kit and DTT were purchased from Thermo Fisher Scientific. LC/MS-grade water and formic acid were purchased from Fisher Scientific. Iodoacetamide (IAA) was purchased from Millipore Sigma.1 g C18 SepPak cartridges were purchased from Waters.
+ Open protocol
+ Expand
4

Epigenetic Enzyme Activity Assays

Check if the same lab product or an alternative is used in the 5 most similar protocols
The activity of HAT was assayed using a HAT activity assay kit (p-4003, Epigentek, NY, USA), and the activity of HDACs was assayed using a HDAC activity assay kit (P-4034, Epigentek, USA), following the manufacturer’s instructions.
+ Open protocol
+ Expand
5

Quantitative Proteomics of HDAC Inhibitors

Check if the same lab product or an alternative is used in the 5 most similar protocols
Romidepsin (S3020), Panobinostat (S1030), and Vorinostat (SAHA) (S1047) were purchased from Selleck Chemicals. Nuclear Extraction kit (40010) was purchased from Active Motif. HDAC Activity Assay kit (P-4034–96) was purchased from Epigentek. MTT assay kit was purchased from Abcam (ab211091). TMTpro 16plex Label Reagent set (A44522), trypsin, BCA assay kit and DTT were purchased from Thermo Fisher Scientific. LC/MS-grade water and formic acid were purchased from Fisher Scientific. Iodoacetamide (IAA) was purchased from Millipore Sigma.1 g C18 SepPak cartridges were purchased from Waters.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!