The largest database of trusted experimental protocols

Uptisphere c18

Manufactured by Interchim
Sourced in France

Uptisphere C18 is a reversed-phase high-performance liquid chromatography (HPLC) column. The column features a silica-based stationary phase with chemically bonded C18 alkyl chains, providing a hydrophobic environment for the separation of a wide range of organic compounds.

Automatically generated - may contain errors

2 protocols using uptisphere c18

1

Qualitative Analysis of PEO by LC-DAD-ESI-MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
The qualitative analysis of the PEO by LC-DAD-ESI-MS was performed using an Agilent 1100 series HPLC systems equipped with a vacuum degasser, diode array detector and a triple quadrupole mass spectrometer type MicromassAutospecUltimaPt (Kelso, UK) operating in negative mode. Separation was performed on a reverse-phase Uptisphere C18 (Interchim, Montfluçon, France) (2 mm × 100 mm, 5 μm particle size) using a mobile phase consisting of A (0.1% acetic acid in water) and B (acetonitrile) at a flow rate of 0.25 mL min−1. The gradient system was 0 min (5% B), 65 min (100% B), 67 min (100% B), and 70 min (5% B). The flow rate of the mobile phase was fixed at 0.25 mL min−1. The column temperature was 40 °C and the injection volume was 20 μL. UV spectra were recorded in the range 190–800 nm. The MS conditions were as follow: mass spectra were collected in negative ion mode from 135 and 700 m/z, capillary voltage, 3.2 kV; cone voltage, 40 V; probe temperature, 300 °C; and ion source temperature, 130 °C.
+ Open protocol
+ Expand
2

Spectroscopic Analysis of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were measured using an MCP-300 polarimeter (Anton Paar, Les Ulis, France). 1D and 2D NMR spectra were recorded on Avance 500 and 600 MHz spectrometers (Bruker, Wissembourg, France). The chemical shifts are relative to the residual signal solvent (CD3OD: δH 3.31; δC 49.20). High-resolution mass spectra were obtained on an LCT Premier XE spectrometer (Waters, Guyancourt, France) in electrospray ionization mode by direct infusion of the purified compounds. Chromatography on silica gel columns, was carried out on silica (Macherey-Nagel 60, 40–63 µm, Hoerdt, France), using a gradient of cyclohexane, ethyl acetate, methylene chloride, and methanol (Sigma-Aldrich, Saint-Quentin Fallavier, France). High performance liquid chromatography was performed on a 1260 Infinity system (Agilent, Les Ulis, France) equipped with a photodiode array detector (G1315C), an evaporative light scattering detector (G4260B), using an analytical reversed phase column Uptisphere C18 (4.6 mm × 250 mm, 5 µm, Interchim, Montluçon, France), and a semi-preparative Uptishere C18 (7.8 × 250 mm, 5 µm).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!