Analytical Characterization of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were measured on a JASCO P-1020 automatic digital polarimeter at room temperature. IR spectra were recorded on a Bruker Tensor 27 spectrometer using KBr pellets. UV spectra were recorded on a Shimadzu UV-2450 spectrophotometer (Shimadzu, Tokyo, Japan). High-resolution electrospray ionization mass spectrometry (HRESIMS) was obtained on an Agilent 6529B Q-TOF mass instrument using electrospray ionization. The 1D and 2D nuclear magnetic resonance (NMR) spectra were obtained on Bruker AVANCE III 500 MHz or Bruker AVIIIHD 600 MHz spectrometers in CDCl3 with TMS as an internal standard. Analytical HPLC was conducted on an Agilent 1260 infinity system equipped with a DAD-UV detector. Preparative HPLC was carried out using a Shimadzu LC-6A system (Shimadzu, Tokyo, Japan) equipped with a Shim-pack RP-C18 column (20 × 200 mm, i.d. 10 μm, Shimadzu, Tokyo, Japan) with a flow rate of 10.0 mL/min, detected by a binary channel UV detector. Silica gel (200–300 mesh, Qingdao Haiyang Chemical Co. Ltd., China), MCI (Mitsubishi, Japan), and RP-C18 silica (40–63 μm, FuJi, Japan) were used for column chromatography.
+ Open protocol
+ Expand
2

Spectroscopic Characterization of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
The optical rotations were measured on a JASCO P-1020 polarimeter at room temperature. The melting points were measured using an X-4 digital display micromelting apparatus and are uncorrected. The IR spectra were recorded on a Bruker Tensor 27 spectrometer using KBr pellets. The 1D- and 2D-NMR spectra were measured on a Bruker AVIII-500 NMR instrument (1H: 500 MHz, 13C: 125 MHz) using TMS as the internal standards. HRESIMS was performed on an Agilent 6529B Q-TOF mass instrument using electrospray ionization. All of the solvents used were of analytical grade (Jiangsu Hanbang Science and Technology. Co., Ltd.). Silica gel (200–300 mesh, Qingdao Haiyang Chemical Co., Ltd, China), Sephadex LH-20 (Pharmacia, Sweden), MCI (Mitsubishi, Japan) and RP-C18 silica (40–63 μm, Fuji, Japan) were used for the column chromatography. Preparative HPLC was conducted using an Agilent 1260 Series instrument with a Shim-Pak RP-C18 column (20 × 200 mm), at a flow rate of 10.0 mL/min, and detection by a binary channel UV detector. The fractions obtained from CC were monitored by TLC with precoated Silica gel GF254 (Qingdao Haiyang Chemical Co., Ltd, China) plates.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!