Ec 150 2 nucleodur 100 3 c18ec column

Manufactured by Macherey-Nagel
Sourced in France

The EC 150/2 Nucleodur 100-3 C18ec column is a chromatography column designed for high-performance liquid chromatography (HPLC) applications. It features a C18 stationary phase with a particle size of 3 μm and a column dimension of 150 mm length and 2 mm internal diameter.

Automatically generated - may contain errors

2 protocols using ec 150 2 nucleodur 100 3 c18ec column

1

LC-MS/MS Analysis of Metabolites

Check if the same lab product or an alternative is used in the 5 most similar protocols
LC-MS/MS analysis was performed on a Thermo Finnigan (Villebon sur Yvette, France) LCQ Advantage ion trap mass spectrometer with an Electrospray Ionisation (ESI) source coupled to a Thermo Scientific Accela HPLC system (MS pump plus, autosampler, and PDA detector plus) with an EC 150/2 Nucleodur 100-3 C18ec column (Macherey-Nagel, Hoerdt, France). A gradient of water and acetonitrile (ACN) was applied from 5% to 30% ACN in 60 min and from 30% to 90% ACN in another 60 min at 30 °C. The flow rate was 0.3 mL/min. The injection volume was about 25 µL. All samples were measured in the positive and negative mode. The MS was operated with a capillary voltage of 10 V, source temperature of 240 °C, and high purity nitrogen as a sheath and auxiliary gas at a flow rate of 70 and 10 (arbitrary units), respectively. The ion was detected in a mass range of 50–2000 m/z, and collision energy of 35% was used in MS/MS for fragmentation. Data acquisitions were executed by Xcalibur 2.0.7 (Thermo Scientific, Illkirch-Graffenstaden, France).
+ Open protocol
+ Expand
2

LC-MS/MS Metabolite Profiling Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
LC-MS/MS analysis was performed on a Thermo Finnigan LCQ Advantage ion trap mass spectrometer with an ESI source coupled to a Thermo Scientific Accela HPLC system (MS pump plus, autosampler, and PDA detector plus) with an EC 150/2 Nucleodur 100-3 C18ec column (Macherey-Nagel). A gradient of water and acetonitrile (ACN) was applied from 5% to 30% ACN in 60 min. The flow rate was 0.3 mL/min. The MS was operated in the negative mode with a capillary voltage of 10 V, source temperature of 240 °C, and high purity nitrogen as a sheath and auxiliary gas at a flow rate of 70 and 10 (arbitrary units), respectively. Data acquisitions were executed by XcaliburTM 2.0.7 software (Thermo Scientific). The ions were detected in a mass range of 50–2000 m/z.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!