Measuring Blood Pressure and Artery Flow in Pregnant Rats

Check if the same lab product or an alternative is used in the 5 most similar protocols
As previously described [28 (link), 29 (link)], the blood pressure of conscious pregnant rats was measured using an automated computerized tail-cuff system after five consecutive training periods (Visitech BP2000, Visitech Systems, Inc., USA). The blood flow of the rat uterine artery was measured using a high-resolution ultrasound device (Esaote MyLab30 Gold, Esaote, Genova, Italy) to obtain two-dimensional images. Twenty-four-hour urine samples were collected on GD7.5 and GD19.5 for urine protein analysis.
+ Open protocol
+ Expand
2

Automated Blood Pressure Monitoring

Check if the same lab product or an alternative is used in the 5 most similar protocols
Heart rate and systolic blood pressure were measured using an automated computerized tail-cuff system in 16-week-old chow and HFD fed conscious mice, as described previously (Visitech BP2000, Visitech Systems, Inc., Apex, USA).21 (link)
+ Open protocol
+ Expand
3

Angiotensin II Mouse Hypertension Model

Check if the same lab product or an alternative is used in the 5 most similar protocols
8-16 week old male mice were anaesthetized with isoflurane by inhalation and osmotic mini-pumps (Alza Corp, USA) delivering saline or Ang II (0.8 or 3 mg/kg/day; Sigma-Aldrich, UK) for 3, 5 or 14 days were implanted subcutaneously. Systolic blood pressure was measured using a non-invasive computerized tail-cuff system in 16 week old conscious mice following a 1 week training period (Visitech BP2000, Visitech Systems, Inc., USA).
+ Open protocol
+ Expand
4

Measuring Hemodynamic Responses to HF Diet and IH

Check if the same lab product or an alternative is used in the 5 most similar protocols
To evaluate the influence of HF diet and IH on the hemodynamic parameters, mean arterial blood pressure and heart rate were measured using a tail cuff sphygmomanometer (Visitech BP-2000; Visitech Systems, Apex, NC). Measurements were made in all mice in the final week of the entire study period. Briefly, the mice were placed into a warm (35°C) restrainer with a size-appropriate cuff around the tail. To minimize any stress-induced fluctuations in blood pressure among animals, all measurements were done after a 10-min adaptation period. The mice were habituated to the procedure for 3 consecutive days before the actual measurement was made on the 4th day. All measurements were performed between 9:30 and 11:30 AM, and recordings were averaged from at least 10 consecutive readings.
+ Open protocol
+ Expand
5

Hypotensive Rat Model for BP Study

Check if the same lab product or an alternative is used in the 5 most similar protocols
Adult male Sprague–Dawley rats (weight, 250–300 g; age, 7–8 weeks) were used in this study. The systemic hypotensive rat model was designed using HCTZ (Dichlozid; Yuhan, Seoul, Korea; 100 mg/kg dissolved in drinking water) to lower systemic BP without interfering with the Ang pathways [23 (link),38 (link)]. The animals were randomly assigned to either the experimental or control groups. Systolic and diastolic BP were measured using a tail cuff sphygmomanometer (Visitech BP2000, Visitech Systems, Apex, NC, USA) twice daily at the same time [39 (link),40 (link)]. Measurements were obtained every week throughout the 12-week experimental period, and the mean value of the two measurements was calculated. The time and frequency of water drinking by individual rats were irregular, which could induce BP fluctuations. Rats without a significant reduction in systolic BP < 120 mmHg or diastolic BP < 80 mmHg were excluded (7 of 104 animals; 6.7%). The standard deviations (SDs) of all measurements were calculated and the mean SD of each group was considered the BP fluctuation.
+ Open protocol
+ Expand
6

Non-Invasive Blood Pressure Measurement in Mice

Check if the same lab product or an alternative is used in the 5 most similar protocols
Arterial pressure was measured using a non-invasive blood pressure measurement system, i.e. a tail-cuff sphygmomanometer equipped with the photoplethysmogram Visitech BP-2000 (Visitech Systems, Apex, NC). Mice were accustomed to the procedure for 5 consecutive days before measurement and were monitored weekly during the 7 weeks of the study. For blood pressure measurements, the mice were placed in a warm (37 °C) restraint device with an appropriately sized cuff around the tail. In order to minimize stress-induced blood pressure fluctuations in the animals, all measurements were taken after a 5-min adaptation period. All measurements of diastolic and systolic pressures were taken between 9:00 a.m. and 12:00 a.m., and recordings were averaged from at least 5 consecutive readings using BP-2000 analysis software. Mean arterial pressure was calculated using following formula: [(2 × diastolic) + systolic]/3.
+ Open protocol
+ Expand
7

Tail-Cuff Blood Pressure Measurement

Check if the same lab product or an alternative is used in the 5 most similar protocols
SBP was measured using a tail-cuff sphygmomanometer (Visitech BP2000, Visitech Systems, Apex, NC). All animals were acclimated for blood pressure measurements 1 week before drug treatment.
+ Open protocol
+ Expand
8

Echocardiography and Tail-Cuff Blood Pressure

Check if the same lab product or an alternative is used in the 5 most similar protocols
Anatomic parameters were obtained by 2D‐directed M‐mode echocardiography (Vevo770; Visual Sonics, Bothell, WA), functional parameters by Doppler Ultrasound (Model DSPW, Indus Instruments, Webster, TX) as described previously (Duerrschmid et al. 2013). Data were stored and analyzed offline. Blood pressure measurements were obtained by the tail‐cuff method (VisitechBP2000, Visitech Systems, Apex, NC) (Duerrschmid et al. 2013).
+ Open protocol
+ Expand
9

Comprehensive Metabolic and Blood Pressure Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Assay and Blood Pressure Measurement Serum or urinary creatinine, electrolytes, uric acid, sugar and insulin levels were measured by using the SYNCHRON CX DELTA system [Beckman, Fullerton, CA, USA] according to manufacturer's operating protocol. Urinary excretion of protein was presented as ratio of urine total protein to creatinine (mg/gm). Urinary uric acid excretion was calculated as ratio of uric acid divided by creatinine (mg/mg). Blood pressure was measured by indirect tailcuff method (Visitech BP2000, Visitech Systems, Apex, NC, USA). Data of three consecutive measurements were recorded and then averaged for each animal.
+ Open protocol
+ Expand
10

Measuring Growth and Blood Pressure in Rats

Check if the same lab product or an alternative is used in the 5 most similar protocols
Body weight (BW) of the offspring was measured every month until they reached 6 months of age. Blood pressure was measured in conscious, 6-month-old rats using the indirect tail-cuff method (BP-2000; Visitech Systems, Inc., Apex, NC) [6 (link), 18 (link)].
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!