The largest database of trusted experimental protocols

Csb e12770m

Manufactured by Cusabio
Sourced in United States

The CSB-E12770m is a laboratory equipment product. It is designed to perform a specific function in a laboratory setting. This description is provided without interpretation or extrapolation on the intended use of the product.

Automatically generated - may contain errors

4 protocols using csb e12770m

1

Serum Hormone Profiling by ELISA

Check if the same lab product or an alternative is used in the 5 most similar protocols
All blood samples were centrifuged at 1,000 g for 10 min and the serum was collected. Concentrations of follicle stimulating hormone (FSH), progesterone (P), luteinizing hormone (LH), and testosterone (T) in serum samples were determined by ELISA kit (CSB-E06871m, CSB-E05104m, CSB-E12770m, CSB-E05101m, CusaBio, Wuhan, China) according to the manufacturer's instructions, and all samples were repeated three times.
+ Open protocol
+ Expand
2

Mouse Hormonal Profile Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood samples were collected by cardiac puncture under anesthesia. Blood samples were centrifuged at 3000 rpm, and serum was separated and stored at −80°C for subsequent blood analysis. ELISA kits were used to measure mouse plasma follicle stimulating hormone (FSH) (CSB-E12770 m, CUSABIO), luteinizing hormone (LH) (CSB-E06871 m, CUSABIO), testosterone (T) (CSB-E05101 m, CUSABIO), anti-Müllerian hormone (AMH) (CSB-E13156 m, CUSABIO), and Irisin (DRE-M9930c, Kmaels) levels.
+ Open protocol
+ Expand
3

Enzymatic Synthesis of High-DHA Fish Oil

Check if the same lab product or an alternative is used in the 5 most similar protocols
Fish oil (DHA content > 80%) was obtained from Shanxi Taike Biotech Co., Ltd. (20200712-002, Xi’an, China). Rhizomucor miehei lipase (L8621) was obtained from Solarbio (Beijing, China). Ethyl dimethylaminopropyl carbodiimide (EDC), benzylamine, dichloromethane, HOBt ·H2O, and triethylamine were obtained from Aladdin Co., Ltd. (Shanghai, China). The 3,3-diaminobenzidine kit (20×) (CW0125) was obtained from Cwbio Co., Ltd. (Beijing, China). Proteinase K (BL104A) and anti-fluorescence quenching mounting fluid (BL701A) were obtained from Biosharp Co., Ltd. (Hefei, China). Anti-FSHR (#40941) and anti-Müllerian-inhibiting factor (#42063) polyclonal antibodies were obtained from SAB Co., Ltd. (Baltimore, MD, USA).
Enzyme-linked immunosorbent assay (ELISA) kits for luteinizing hormone (LH; CSB-E12770m), follicle-stimulating hormone (FSH; CSB-E06871m), estradiol (E2; CSB-E05109m), and anti-Müllerian hormone (AMH; CSB-E13156m) were obtained from Cusabio Biotech Co., Ltd. (Wuhan, China). Evo M-MLV RT Mix Kit with gDNA Clean for qPCR (AG11728) and SYBR Green Pro Taq HS premixed qPCR kits (AG11701) were obtained from AgBio Co., Ltd. (Changsha, China). A TUNEL kit (in situ cell death detection; C1086) and DAPI (4′,6-diamidino-2-phenylindole; C1005) were obtained from Beyotime Biotech Co., Ltd. (Shanghai, China).
+ Open protocol
+ Expand
4

Hormones and Oxidative Stress in Mice

Check if the same lab product or an alternative is used in the 5 most similar protocols
Freshly collected blood samples from the mice were stood at room temperature for 2 h and centrifuged (1000g, 4°C) for 10 min. Serum hormones follicle-stimulating hormone (FSH), luteinizing hormone (LH), and estradiol (E2) were detected using the ELISA kit (CSB-E06871m, CSB-E12770m, CSB-E07280m, Cusabio, Wuhan, China) in strict accordance with the instructions. The absorbance was measured at 450 nm. The ovarian and oocytes sample lysis fluid were diluted to the optimal concentration to meet the standard curve for detection. Biomarkers related to oxidative stress including total antioxidant capacity (T-AOC), 8-hydroxy-2 deoxyguanosine (8-OH-dG), advanced oxidation protein products (AOPP), molondialdehyde (MDA), superoxide dismutase (SOD), glutathione peroxidase (GSH-Px) were detected by ELISA assay kit (A015-1-2, A001-3-2, A005-1-2, Jiancheng Bioengineering Institute, Nanjing, China; ab201734, ab242295, ab118970, Abcam, USA) following the manufacturer's instructions. The absorbance values were measured using a microplate reader (VersaMax, Molecular Devices, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!