The largest database of trusted experimental protocols

Pluronic l64

Manufactured by BASF
Sourced in Germany, Japan

Pluronic L64 is a nonionic triblock copolymer surfactant. It is composed of a central hydrophobic block of polypropylene oxide (PPO) flanked by two hydrophilic blocks of polyethylene oxide (PEO). Pluronic L64 is a common laboratory reagent used for its emulsifying, dispersing, and solubilizing properties.

Automatically generated - may contain errors

2 protocols using pluronic l64

1

Solubilization and Characterization of DTX

Check if the same lab product or an alternative is used in the 5 most similar protocols
DTX was provided by Korea United Pharma Inc. (Seoul, Korea). Lauroglycol 90, Lauroglycol FCC, Labrafac Lipophile WL 1349, Labrafac CC, Capryol 90, Labrafil M 1944 CS, Transcutol P, and Labrasol were obtained from Gattefossé Co. (Lyon, France). Capmul MCM was purchased from the Abitec Corporation (Cleveland, OH, USA). Polyethylene glycol 400 (PEG 400), Tween 20, and Tween 80 were bought from Samchun Chemical Co., Ltd (Pyungtaek, Korea). Cremophor EL and Pluronic L64 were provided by BASF Co. (Ludwigshafen, Germany). Tetraglycol, propylene glycol, dimethyl sulfoxide (DMSO), Coumarin-6 (C6), and 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) were purchased from Sigma-Aldrich (St. Louis, MO, USA). Lipoid® S100 (phospholipid, PLC) was obtained from Lipoid Co. (Ludwigshafen, Germany). The high-performance liquid chromatography (HPLC) grade methanol, acetonitrile, n-hexane, and ethanol were bought from J.T. Baker (Phillipsburg, NJ, USA).
+ Open protocol
+ Expand
2

Pluronic-Mediated Hepcidin Peptide Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Pluronic L121 (PEO5-PPO70-PEO5), Pluronic L64 (PEO13-PPO30-PEO13) and Pluronic F127 (PEO106-PPO70-PEO106) are gift from BASF Co.. All the other chemicals utilized in the study were purchased from Sigma-Aldrich Co.. Synthetic human hepcidin was obtained from Peptides Institute Inc. (Osaka, Japan). Rabbit serum was obtained from Solarbio Science & Technology Co. (Beijing, China). Peptide analysis was carried out using a Bruker Daltonics’ MicroflexTM LRF MALDI-TOF (Billerica, MA, USA). LC-MS/MS was performed using HPLC (Agilent 1200 series) and LTQ-Orbitrap XL (Thermo, San Jose, CA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!