L type wako glu2

Manufactured by Fujifilm
Sourced in Japan

The L type Wako Glu2 is a lab equipment product by Fujifilm. It is designed to measure glucose levels in various samples. The core function of this product is to provide accurate and reliable glucose analysis.

Automatically generated - may contain errors

3 protocols using l type wako glu2

1

Serum Biomarker Determination Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Serum GH levels were determined by Electro Chemiluminescence Immunoassay using Cobas 8000 analyzer series module e801 (Roche Diagnostics, Mannheim, Germany; %CV of intra-assay variability <15%). The serum glucose level was determined by hexokinase enzymatic method (L-type Wako Glu2; Wako Pure Chemical Industries, Osaka, Japan) using LABOSPECT 008 α (HITACHI, Tokyo, Japan) and JCA-BM8060 (JEOL, Tokyo, Japan). The lactate level was determined by enzymatic method (Deteminer LA; Minaris Medical, Tokyo, Japan) using JCA-BM9130 (JEOL, Tokyo, Japan). Serum insulin levels were determined by Chemiluminescent Immunoassay using Architect i2000 SR (Abbott, Osaka, Japan). Plasma amino acids fractionation was determined by High-Pressure Liquid Chromatography using a Modification of the 6-Aminoquinolyl-N-Hydroxysuccinimidyl Carbamate (AQC) Method on a Waters Acquity UPLC system. GH, glucose, insulin, amino acids, and lactate levels were analyzed by the LSI Medience Corporation (Kyoto, Japan). Acylated ghrelin levels were measured using an Active Ghrelin ELISA Kit (# 97751, LSI Medience, Tokyo, Japan).
+ Open protocol
+ Expand
2

Monthly Metabolic Monitoring in Rats

Check if the same lab product or an alternative is used in the 5 most similar protocols
Body weight, blood glucose, and glycated hemoglobin (HbA1c) were measured once monthly. Blood samples were collected from the tail vein of nonfasting rats to measure the blood glucose and HbA1c. Blood glucose was measured by the hexokinase-G-6-PDH method (L type Wako Glu2, Wako Pure Chemical Industries, Ltd., Osaka, Japan). HbA1c was measured using an automated glycohemoglobin analyzer (HLC-723GHb V, Tosoh Corporation, Tokyo, Japan) [21 ].
+ Open protocol
+ Expand
3

Longitudinal Assessment of Metabolic Markers

Check if the same lab product or an alternative is used in the 5 most similar protocols
Body weight, blood glucose, and glycated hemoglobin (HbA1c) were measured once monthly. Blood samples to measure the blood glucose and HbA1c were collected from the tail vein of nonfasting rats. Blood glucose was measured by the hexokinase/glucose-6-phosphate dehydrogenase method (L type Wako Glu2, Wako Pure Chemical Industries, Ltd., Osaka, Japan). HbA1c was measured using an automated glycohemoglobin analyzer (HLC-723GHb V, Tosoh Corporation, Tokyo, Japan).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!