The largest database of trusted experimental protocols

Vec 260 vacuum dryer

Manufactured by Iwaki
Sourced in Japan

The VEC-260 is a vacuum dryer manufactured by Iwaki. It is designed to efficiently remove moisture from various materials under controlled vacuum conditions. The core function of the VEC-260 is to provide a consistent and reliable drying process for a range of applications.

Automatically generated - may contain errors

3 protocols using vec 260 vacuum dryer

1

Protein Reduction, Alkylation, and Trypsin Digestion

Check if the same lab product or an alternative is used in the 5 most similar protocols
Precipitated proteins were dissolved in 100 µL of 8 M urea, with a 50 mM Tris-HCl (pH 8.0) buffer. The sample was treated by 2 µL of 1 M Dithiothreitol at RT for 1 h and 8 µl of 500 mM Iodoacetamide at RT for 1 h with shading. The alkylation was stopped by 1 µL of 1 M Dithiothreitol and then diluted eight times by 50 mM Tris-HCl (pH 8.0). For the digestion, 1 µg of trypsin (Agilent, Santa Clara, CA, USA) was added to the sample and incubated at 37 °C for 16 h with shaking. The digestion was stopped by the addition of 1 µL of 50% Trifluoro acetic acid (TFA). The digested sample was purified by C18 spin column (GL Science, Tokyo, Japan) according to the manual. Briefly, a C18 spin column was activated by 100% and 50% acetonitrile sequentially and then equilibrated by 0.2% TFA with centrifuging at 3000× g for 30 sec. After conditioning, the sample was loaded into a spin column and centrifuged at 3000× g for 90 sec. Then, trapped peptides were washed by 0.2% TFA twice and eluted by 95% acetonitrile with 5% formic acid. The eluted sample was dried up by a VEC-260 vacuum dryer (Iwaki, Tokyo, Japan). The sample was re-suspended by 0.1% formic acid and the peptide concentration was measured by Nano drop 1000 (Thermo, Bremen, Germany). The sample was stored at −80 °C until use.
+ Open protocol
+ Expand
2

Purification and Quantification of Digested Proteins

Check if the same lab product or an alternative is used in the 5 most similar protocols
The digested protein sample was purified by C18 column (GL Science, Tokyo, Japan), according to the manual. Briefly, C18 column was activated by 100% acetonitrile and stabilized by 50% acetonitrile and 0.2% formic acid (FA). Then, the sample was loaded into the column and centrifuged at 3000× g for 90 s. Then, the trapped peptide sample was washed with 0.2% TFA twice. Finally, the sample was eluted with 95% acetonitrile, 5% FA. The eluted sample was dried up by VEC-260 vacuum dryer (Iwaki, Tokyo, Japan). The sample was re-suspended with 0.1% FA, and then the peptide concentration was quantified by Nanodrop 1000 (Thermo Fisher Scientific, Waltham, MA, USA). The sample was stored at −80 °C until analysis.
+ Open protocol
+ Expand
3

Protein Extraction and Trypsin Digestion

Check if the same lab product or an alternative is used in the 5 most similar protocols
Precipitated proteins were dissolved in 100 µL of 8 M urea/50 mM Tris-HCl (pH 8.0) buffer. The sample was treated by 1 µL of 1 M dithiothreitol at RT for 1 h and 8 µL of 500 mM iodoacetamide at RT for 1 h with shading. The alkylation was stopped by 1 µL of 1 M dithiothreitol and then diluted eight times by 50 mM Tris-HCl (pH 8.0). For the digestion, 1 µg of trypsin (Agilent, Santa Clara, CA, USA) was added to the sample and incubated at 37 °C for 16 h with shaking. The digestion was stopped by 50% of trifluoro acetic acid (TFA).
The digested sample was purified by C18 spin column (GL Science, Tokyo, Japan) according to the manual. Briefly, a C18 spin column was activated by 100% and 50% acetonitrile sequentially and then equilibrated by 0.2% formic acid with centrifuging at 3000 g for 30 s. After conditioning, the sample was loaded into the spin column and centrifuged at 3000 g for 90 s. Then, trapped peptides were washed with 0.2% TFA twice and eluted by 95% acetonitrile with 5% formic acid. The eluted sample was dried up by VEC-260 vacuum dryer (Iwaki, Tokyo, Japan). The sample was re-suspended by 0.1% formic acid and the peptide concentration was measured by Nano drop 1000 (Thermo Fisher Scientific, Bremen, Germany). The sample was stored at −80 °C until use.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!