The largest database of trusted experimental protocols

E pure water

Manufactured by Thermo Fisher Scientific
Sourced in United States

The E-Pure water system is a lab equipment product that produces high-purity deionized water. It utilizes a combination of ion exchange resins and membrane filtration technology to remove impurities from the input water supply, resulting in purified water suitable for various laboratory applications.

Automatically generated - may contain errors

2 protocols using e pure water

1

Sugar Analysis by HPLC

Check if the same lab product or an alternative is used in the 5 most similar protocols
MRP crude samples were re-dissolved in E-Pure water and supernatants were adjusted to 50% acetonitrile (Thermo Fisher Scientific, Waltham, MA, USA) for sugar analysis, analyzed by high-performance liquid chromatography (HPLC), using an Agilent 1100 series (Santa Clara, California, USA), equipped with a Agilent, 5 µm, 4.6 × 250 mm column and a refractive index detector [21 (link)]. The mobile phase contained 75% acetonitrile and the flow rate was 1.0 mL/min. Standard calibration curves of xylose, glucose, fructose, and sucrose were built for quantitative analysis with a concentration range of 0.625–20 mg/mL. Ribose was used as an internal standard.
+ Open protocol
+ Expand
2

Quantitative Analysis of Yeast Metabolites

Check if the same lab product or an alternative is used in the 5 most similar protocols
The OD600 of cultures was measured using a spectrophotometer (Biomate 5, Thermo, NY) and dried cell weight (DCW) was obtained from an experimentally determined conversion factor of 0.454 g DCW/OD600. Extracellular metabolites such as lactose, galactose, galactitol, glycerol, acetate, and ethanol were measured by HPLC (Agilent Technologies 1200 Series, Santa Clara, CA) with a RezexTM ROA-Organic Acid H + (8%) column (Phenomenex Inc., Torrance, CA) and a refractive index detector (RID). The column was eluted with 0.005 N H2SO4 at a flow rate of 0.6 mL/min at 50 °C. Galactose and tagatose could not be separated by this ROA-organic acid H + (8%) column (Supplementary Figure 3). Galactose and tagatose concentrations were measured using an Agilent Technologies 1200 Series HPLC equipped with a RezexTM RCM-Monosaccharide Ca + 2 (8%) column (Phenomenex Inc. Torrance, CA) and RID detector. The mobile phase was E-Pure™ Water (Barnstead E-Pure™ Water Purification Systems, Thermo Scientific) and was eluted at a flow rate of 0.6 mL/min at 80 °C. The maxium theoretical tagatose yield (0.526 g tagatose/g lactose) by engineered yeast was calculated based on the molecular weights of tagatose (180.16 g/mol) and lactose (342.3 g/mol) with an assumption that glucose is not converted into tagatose.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!