The largest database of trusted experimental protocols

2 protocols using jnm ecs 400 mhz

1

Analytical Techniques for Compound Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Sephadex LH-20 (Merck KGaA, Darmstadt, Germany), silica gel 60 (Merck KGaA) and Geduran Si 60 (Merck KGaA) were used for column chromatography. TLC plates (Silica Kiesel 60 F254) were from Merck KGaA. Jasco V-530 ultraviolet spectrophotometer (Jasco International Co., Ltd, Tokyo, Japan) was used to measure UV spectra. IR spectra were obtained on an FT-IR-4100 Jasco spectrophotometer (Jasco). Optical rotations were achieved by a Jasco P-2000 digital polarimeter (Jasco). NMR spectra were obtained by JEOL JNM ECS 400 MHz. Electrospray ionization mass spectrometry (ESIMS) data were collected on a Waters micromass ZQ mass spectrometer (Waters Corporation, Milford, MA, USA). High-resolution ESIMS data was accomplished by a Bruker APEX II spectrometer (FT-ICR/MS, FTMS) (Bruker Daltonics Inc., Billerica, MA, USA). Dulbecco’s modified Eagle’s medium (high glucose) powder (DMEM), 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT), p-nitrophenyl-N-acetyl-d-glucosaminide (p-NAG), penicillin and streptomycin, dexamethasone, calcium ionophore A23187, and dimethyl sulfoxide (DMSO) were purchased from Sigma-Aldrich (St. Louis, MO, USA). Fetal bovine serum (FBS) was obtained from Hyclone (Logan, UT, USA). Mouse anti-DNP IgE antibody was a generous gift from Dr. Daniel H. Conrad (Virginia Commonwealth University, Richmond, VA, USA).
+ Open protocol
+ Expand
2

Phytochemical Analysis by Chromatography and Spectroscopy

Check if the same lab product or an alternative is used in the 5 most similar protocols
Sephadex (GE healthcare) LH-20 and silica gel 60 (Merck KGaA, Darmstadt, Germany) were used for open-column chromatography (CC). Luna C18, phenyl-hexyl (5 μm, 250 × 10 mm, Phenomenex, Torrance, CA, USA) semi-preparative columns were used for high-performance liquid chromatography (HPLC). HPLC instrument used a Shimadzu LC-10AT pump with an SPD-20A UV-Vis detector. The UV spectra were obtained by using a Jasco UV-530 ultraviolet spectrophotometer (Jasco, Tokyo, Japan), whereas the IR spectra were obtained on a Jasco FT-IR-4600 spectrophotometer (Jasco, Tokyo, Japan). Optical rotations were measured with a Jasco P-1020 digital polarimeter (Jasco, Tokyo, Japan). NMR spectra were obtained using JEOL JNM ECS 400 MHz (JEOL, Tokyo, Japan), Varian 600 MHz NMR (Varian, Palo Alto, CA, USA), and Bruker AVIIIHD700X 700 MHz spectrometers (Bruker, Bremen, Germany). ESI–MS data were collected on a VG Biotech Quattro 5022 mass spectrometer (VG Biotech, Altrincham, UK). High-resolution ESI–MS data were obtained with a Bruker APEX II spectrometer (Bruker, Bremen, Germany). Circular dichroism spectra were recorded on a JASCO J-810 spectrophotometer (Jasco, Tokyo, Japan).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!