The largest database of trusted experimental protocols

Discovery 790 elite

Manufactured by GE Healthcare

The Discovery 790 Elite is a high-performance PET/CT system designed for advanced imaging applications in healthcare. It combines state-of-the-art PET and CT technologies to provide comprehensive diagnostic information. The system's core function is to acquire and integrate PET and CT data for comprehensive evaluation of patient conditions.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using discovery 790 elite

1

PET/CT Imaging of Tumor-Bearing Mice

Check if the same lab product or an alternative is used in the 5 most similar protocols
PET/CT imaging of tumor-bearing mice was performed on a clinical time-of-flight (TOF) 64-slice PET/Computed tomography (CT) scanner (Discovery 790 Elite, GE healthcare). The mice bearing tumors (for each group n = 4) were injected with 3.7 MBq (100 μCi) of 18F-IRS into the tail vein. At 30 min, 60 min and 120 min after injection, the mice were anesthetized with 2% isoflurane and placed near the center of the field of view of the PET/CT scanner in prone position. For blocking studies, gefitinib (100 mg/kg) was injected into HCC827 xenografts nude mice (n = 4) via tail vein 60 min before PET/CT imaging. The mice were imaged as described above 120 min after injection.
The images were reconstructed using a two-dimensional ordered-subset expectation maximization (OSEM) algorithm. For each scan, regions of interest (ROIs) were drawn over the tumor and major organs using the AW4.6 software (GE Healthcare) on decay-corrected whole-body coronal images. The radioactivity concentrations (accumulations) within the tumor, muscle were obtained from mean pixel values within the multiple ROI volumes and then converted to megabecquerels per milliliter per minute using the calibration factor determined for the PET system. These values were then divided by the administered activity to obtain (assuming a tissue density of 1 g/ml) an image ROI-derived percent injected dose per gram (% ID/g).
+ Open protocol
+ Expand
2

EGFR-TKI Uptake Analysis via 18F-MPG PET/CT

Check if the same lab product or an alternative is used in the 5 most similar protocols
All patients involved in this study had 18F-FDG PET/CT imaging. Image acquisition parameters for each cohort are presented in Supplementary Table 11. Since uptake of EGFR-TKI PD153035 based on 18F-MPG is highly correlated with EGFR mutation status15 (link),29 (link),30 (link), 18F-MPG PET/CT imaging (Discovery 790 Elite; GE Healthcare) was also performed on HMU cohort. Scanning was initiated 1 h after administration of ~259 MBq of 18F-MPG. Whole-body CT scans were firstly acquired for attenuation correction by using a low-dose protocol (40 mA, 120 keV), and PET data were subsequently acquired in 3D mode. The anisotropic resolutions for CT and PET images were 0.98 × 0.98 × 3.75 mm3 and 3.65 × 3.65 × 3.27 mm3, respectively15 (link).
All PET images were converted into SUV units by normalizing the activity concentration to the dosage of 18F-FDG injected and the patient body weight after decay correction, and all CT images were converted into lung window.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!