The largest database of trusted experimental protocols

Ma5 11 202

Manufactured by Thermo Fisher Scientific

The MA5-11,202 is a laboratory equipment product from Thermo Fisher Scientific. It is designed to perform a specific core function, but a detailed description while maintaining an unbiased and factual approach is not available.

Automatically generated - may contain errors

3 protocols using ma5 11 202

1

MUC1 Peptide ELISA Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
A 96-well ELISA plate (Pierce Streptavidin High Binding Capacity, Clear) was coated with 100 µl/well of biotinylated PDTRPAPGSTAPPAHGVTSA MUC1 peptide (synthesized by JPT Peptide Technologies) adjusted to 10 µg/ml. The coated plate was incubated for 2 h with shaking at room temperature. Then the plate was washed 4 × 5 min with 200 µl/well of wash buffer (Tris buffered saline pH 7,2/0,1%BSA/0,05%Tween20). Next, 100 µl/well of L. tarentolae cell lysates (WT, NoV VP1 and NoV VP1-MUC1 lysates) were used to coat the plate. The plate was incubated for 2 h with shaking in room temperature. The plate was washed as previously. Next, 100 µl/well of Armenian hamster anti-MUC1 antibody (MA5-11,202, Thermo Fisher Scientific; 1:100 in wash buffer) was added and the plate was incubated for 1 h at room temperature, then washed as previously. Then 100 µl/well of Peroxidase-conjugated mouse anti-Armenian hamster antibody (Santa Cruz Biotechnology; 1:2000 in wash buffer) was added and incubated for 1 h at room temperature. The plate was washed as previously and 100 µl/well of HRP-substrate solution was added (1-Step Turbo TMB-ELISA, Thermo Scientific). The plate was incubated in dark until the blue color developed and the reaction was stopped by adding 50 µL of 0,5 M sulfuric acid to each well. Signal intensity was measured at 450 nm using a plate reader (Epoch, Biotek).
+ Open protocol
+ Expand
2

ELISA for MUC1 antibody detection

Check if the same lab product or an alternative is used in the 5 most similar protocols
Sera from immunized mice were collected and pooled on day 56 after immunization. A 96-well ELISA plate (Greiner Microlon High-Binding, clear) was coated with 100 µl/well of L. tarentolae cell lysates (WT and NoV VP1-MUC1 lysates). The coated plate was incubated overnight at 4 °C. Next, the plate was washed 4 × 5 min with 200 µl/well of washing buffer (PBS/0,05%Tween20) and blocked for 2 h with 250 µl/well of blocking buffer (3%BSA/PBS/0,05%Tween20) at 37 °C. The plate was washed as previously and serial dilutions of pooled mouse sera (in 3%BSA/PBS/0,05%Tween20) were added to the wells and incubated for 1 h at room temperature. Serial dilutions of Armenian hamster anti-MUC1 antibody (MA5-11,202, Thermo Fisher Scientific; in 3%BSA/PBS/0,05%Tween20) served as a positive control. After incubation the plate was washed as previously, and appropriate secondary antibody solution (Jackson Immuno Research; in 3%BSA/PBS/0,05%Tween20) was used for detection. Finally, following the last plate-washing step (6 × 5 min with 200 µl/well), 100 µl/well of HRP-substrate solution was added (1-Step Turbo TMB-ELISA, Thermo Scientific), the plate was incubated in dark until the blue color developed, and the reaction was stopped by adding 50 µL of 0,5 M sulfuric acid to each well. Signal intensity at 450 nm was measured using a plate reader (Epoch, Biotek).
+ Open protocol
+ Expand
3

ELISA for L. tarentolae-derived VLPs

Check if the same lab product or an alternative is used in the 5 most similar protocols
A 96-well ELISA plate (Greiner Microlon High-Binding, clear) was coated with 100 µl/well of sequential dilutions purified L. tarentolae-derived VLPs (NoV VP1 and NoV VP1-MUC1). WT L. tarentolae cell lysate served as a negative control. The coated plate was incubated overnight at 4 °C. Next, the plate was washed 4 × 5 min with 200 µl/well of washing buffer (PBS/0,05%Tween20) and blocked for 2 h with 250 µl/well of blocking buffer (3%BSA/PBS/0,05%Tween20) at 37 °C. The plate was washed as previously and 100 µl/well of primary rabbit anti-NoV antibodies (Abcam ab92976; in 3%BSA/PBS/0,05%Tween20) and Armenian hamster anti-MUC1 antibody (MA5-11,202, Thermo Fisher Scientific) were added. After incubation the plate was washed as previously, and the appropriate secondary antibody solution (Jackson Immuno Research; in 3%BSA/PBS/0,05%Tween20) was used for detection. Finally, following the last plate-washing step (6 × 5 min with 200 µl/well), 100 µl/well of HRP-substrate solution was added (1-Step Turbo TMB-ELISA, Thermo Scientific), the plate was incubated in dark until the blue color developed, and the reaction was stopped by adding 50 µL of 0,5 M sulfuric acid to each well. Signal intensity at 450 nm was measured using a plate reader (Epoch, Biotek).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!