The largest database of trusted experimental protocols

4 protocols using 1 dodecanthiol

1

Synthesis and Characterization of Metallic Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
Gold(III) chloride trihydrate (~30 wt.% in HCl 99.99%), sodium borohydride (98%), L-ascorbic acid (AA) (≥ 99%), silver nitrate (99.8%), sodium citrate (≥ 99%), hydrochloric acid (≥ 37%), nitric acid (≥ 65%), sulfuric acid (95%), hydrogen peroxide (30 wt.%), ethanol (≥ 99.7%), toluen (≥ 99.7%)N-Dodecyl-N,N-dimethyl-3-ammoniun-1-propansulfunate (LSB; ≥ 99.7%), (3-aminopropyl)trimethoxysilane (APTES; ≥ 98.0%), L-glutathione, reduced (99%), 1-dodecanthiol (≥ 98%), 4-mercaptophenylboronic acid (≥ 99.7%), 4-mercaptobenzoic acid (99%) and 7-Mercapto-4-methylcoumarin (≥ 97%) were purchased from purchased from Sigma-Aldrich (St. Louis, MO, USA). Microscopy cover glass slides 21 mm × 6 mm were purchased from DEL Chimica (Milano, Italy).. All reagents were used as received. All the preparations were made with bidistilled water.
Tryptone Soya Broth (TSB) and Tryptone Soya Agar (TSA) for bacteria culture were purchased from Oxoid, Basingstoke, Hampshire, UK. S. aureus ATCC 6538 and Escherichia coli ATCC 10536 bacterial strains were used.
+ Open protocol
+ Expand
2

Synthesis and Characterization of Folic Acid-Conjugated Quantum Dots

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents were used as received from the suppliers without further purification. Cadmium oxide (CdO, 99.9%) was purchased from Alfa Aesar (Ward Hill, MA, USA). Tri-n-octylphosphine (TOP, 97%) was purchased from STREM Chemicals (Newburyport, MA, USA). Selenium (Se, 99.5%) was purchased from Acros Organics (Geel, Belgium). Sulfur (S, 99%) and ammonium hydroxide (NH4OH, 27%) were purchased from Daejung (Siheung, Korea). Folic acid PEG amine (FA-PEG-NH2) was purchased from Nanocs Inc. (New York, NY, USA). Zinc acetate (Zn(OAc)2, 99.99%), oleic acid (OA, 90%), 1-octadecene (ODE, 90%), 1-octanethiol (98.5%), acetone (99.9%), 3-mercaptopropionic acid (MPA, 99%), 1-dodecanthiol (98%), chloroform (CHCl3, 99.5%), 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC) hydrochloride, N-hydroxysulfosuccinimide (sulfo-NHS), phosphate buffered saline (PBS, pH 7.4), TWEEN® 20, and bovine serum albumin (BSA) were purchased from Sigma Aldrich (St. Louis, MO, USA). KB cell lines were purchased from American Type Culture Collection (ATCC, Manassas, VA, USA). Fetal bovine serum and Roswell Park Memorial institute (RPMI) medium were purchased from Welgene (Daegu, Korea). Antibiotics (penicillin and streptomycin) were purchased from Gibco (Grand Island, NY, USA). Mounting medium containing 4′,6-diamidino-2-phenylindole (DAPI) was purchased from Vectashield (Burlingame, CA, USA).
+ Open protocol
+ Expand
3

Synthesis of CTA Agents for RAFT Copolymerization

Check if the same lab product or an alternative is used in the 5 most similar protocols
1-Dodecanthiol, carbon disulfide, potassium phosphate, 2-bromo-2-methylpropionic acid, and acetone were purchased from Sigma-Aldrich (St. Louis, MO) and used for the synthesis of 2-(dodecylthiocarbonothioylthio)-2-methylpropionic acid as a CTA for the RAFT copolymerization of acrylate monomers. The other CTA, 4-cyano-4-[(dodecylsulfanylthiocarbonyl)sulfanyl]pentanoic acid, was purchased from Sigma-Aldrich and used for the RAFT copolymerizations when the copolymerization mixture contained a methacrylate monomer. Azobisisobutyronitrile (AIBN, 98%) was purchased from Junsei (Tokyo, Japan) and purified by recrystallization in methanol. Poly(ethylene glycol) methyl ether acrylate (PEGA), dodecyl acrylate (DA), poly(ethylene glycol) methyl ether methacrylate (PEGMA), and dodecyl methacrylate (DMA) were purchased from Sigma-Aldrich and TCI (Tokyo, Japan). They were purified by passing through a basic alumina column prior to polymerization. HPLC grade toluene was purchased from Burdick & Jackson (Morristown, NJ) and used as a polymerization solvent after purification using a solvent purification system (C&T International, Suwon, Korea).
+ Open protocol
+ Expand
4

Synthesis of Colloidal Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
All chemicals, indium acetate (In(OAc)3 99.99% trace metal basis Sigma-Aldrich), zinc acetate (Zn(OAc)2 99.99% trace metal basis Sigma-Aldrich), zinc oxide (ZnO 99.999% Sigma-Aldrich), zinc stearate (Zn(St)2 purum, 10–12% Zn basis Sigma Aldrich), myristic acid (99% Sigma), oleic acid (90% technical grade Aldrich), 1-dodecanthiol (≥98% Sigma-Aldrich), gallium trichloride (GaCl3 beads, anhydrous 99.999% trace metal basis Aldrich), selenium powder (200 mesh, 99.99%, Strem), sulfur (99.998%, Sigma-Aldrich), 1-octadecene (ODE 90% technical grade Aldrich), tri-n-octylphosphine (TOP, 97% strem), and tris(trimethylsilyl)phosphine (TMS-P min 98% from SK-chemicals, Korea), were used without any further purification.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!