The largest database of trusted experimental protocols

2 protocols using n hydroxysuccinimide

1

Synthesis and Functionalization of Silica Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
N-Cetyltrimethylammonium bromide (CTAB), tetraethyl orthosilicate (TEOS), sodium hydroxide (NaOH), 3-aminopropyltriethoxysilane (APTES), pyruvic acid (PA), N-hydroxysuccinimide (NHS), 1-ethyl-3-(3-(dimethylamino) propyl) carbodiimide hydrochloride (EDC), (2-thienylmethyl)hydrazine hydrochloride, (5,6-dimethylthieno[2,3-d]pyrimidin-4-yl)hydrazine, trifluoroacetic acid (TFA), triethylamine (TEA), ethanol, 2-propanol from Carl Roth (Carl Roth GmbH & Co. KG, Karlsruhe, Germany), dichloro(p-cymene)ruthenium(II) dimer, phosphate buffered saline (PBS), toluene and crystal violet (CV) were purchased from Sigma-Aldrich (Merck KGaA, Darmstadt, Germany). Dulbecco’s Modified Eagle Medium (DMEM) was purchased from Biowest (Riverside, CA, USA). For in vitro experiments nutrition medium RPMI 1640, FCS (fetal calb serum), penicillin/streptomycin and phosphate buffer saline (PBS) were obtained from Capricorn scientific GmbH (Ebsdorfergrund, Germany), glutamine and 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) from GE healthcare (Chicago, IL, USA) and Biomol GmbH (Hamburg, Germany), respectively.
+ Open protocol
+ Expand
2

Synthesis and Characterization of Iron Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
Iron(II) chloride tetrahydrate (FeCl2⋅4H2O), hydroxylammonium chloride, bovine serum albumin (BSA), and Eppendorf ultrafiltration tubes with a molecular weight cutoff (MWCO) of 3 kDa were purchased from Merck (Darmstadt, Germany). Iron(III) chloride hexahydrate (FeCl3⋅6H2O), dialysis tubes (Spectrapor 6, MWCO 8 kDa), ammonium chloride, formic acid, hydrochloric acid 25 %, ethylcarbodiimide hydrochloride (EDC), N-hydroxysuccinimide (NHS), sodium thiosulfate, silver nitrate, sodium carbonate, and ammonia solution 25 % were supplied by Roth (Karlsruhe, Germany). Propidium iodide (PI), sodium citrate, triton X-100, ninhydrin, MES, HEPES, and poly(acrylic acid-co-maleic acid) solution (Mw = 3000 Da) were purchased from Sigma-Aldrich (St Louis, MO, USA). Ringer’s solution was bought from Baxter Healthcare (Zurich, Switzerland). Annexin V-FITC (AxV), Hoechst 33342 (Hoe), and DiIC1(5) (hexamethylindodicarbocyanine iodide dye [DiI]) were purchased from Thermo Fisher Scientific (Waltham, MA, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!