The largest database of trusted experimental protocols

200 2031 metachem online degasser

Manufactured by Agilent Technologies
Sourced in United States

The 200-2031 Metachem online degasser is a laboratory equipment designed to remove dissolved gases from liquid samples. It functions by applying a vacuum to the liquid, which causes the dissolved gases to be extracted. This process helps to ensure the accuracy and reliability of analytical measurements by eliminating potential interference from gas bubbles.

Automatically generated - may contain errors

2 protocols using 200 2031 metachem online degasser

1

HPLC Quantification of Iloprost Enantiomers

Check if the same lab product or an alternative is used in the 5 most similar protocols
Iloprost solution was carried out using HPLC apparatus (Varian Inc., Palo Alto, USA) equipped with 200-2031 Metachem online degasser, a M210 binary pump, a ProStart 410 auto sampler, a G1316A thermostatic column, a 25 μl CSL20 Cheminert Sample Loop injector. Data was acquired and processed using Galaxie chromatography manager software (Varian Inc., Palo Alto, USA). A GraceSmart RP C18 column (4.6 × 250 mm, 5 μm, Alltech Grom GmbH, Rottenburg-Hailfingen, Germany) was used as a stationary phase during analysis. Deionized water (HPLC grade) acidified with 0.1% v/v trifluoroacetic acid (TFA, HPLC grade) and acetonitrile (HPLC grade) 60:40% v/v was used as the mobile phase. The flow rate was 1 ml/min; while, Iloprost solution was acquired at a maximum wavelength of 205 nm. The drug was separated as an enantiomer at the retention times of 20.5 and 22 min, respectively. Enantiomers were widely separated during analysis and no interference peaks or overlapping of compounds were observed (Supplementary Fig. 1). An external standard curve was carried out to quantify Iloprost solution according to the following equation:
AUC = 0.5899x + 0.0234
where, x is the Iloprost concentration (μg/ml) and AUC (mAU × min) is the area under the curve. A linear correlation with R2 = 0.9998 was carried out in the range from 0.01 to 10 μg/ml.
+ Open protocol
+ Expand
2

HPLC Analysis of Minoxidil Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
Minoxidil content was determined by reverse-phase chromatography using a HPLC system (Varian Inc., Palo Alto, CA, USA) equipped with a 200-2031 Metachem online degasser, a M210 binary pump, a G1316A thermostated column compartment, a ProStar 410 autosampler, and a 25 µL CSL20 Cheminert Sample Loop injector. The Galaxie® chromatography manager software (Varian Inc., Palo Alto, CA, USA) was used to process data. The chromatographic separation was carried out at room temperature using a GraceSmart RP C18 column (4.6 × 250 mm, 5 μm particle size, Alltech Grom GmbH, Rottenburg-Hailfingen, Germany). The mobile phase used for the analysis was a mixture of methanol/water (80:20 v/v). The flow rate was 1.0 mL/min and UV detection was set at 231 nm.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.