The largest database of trusted experimental protocols

1200 series lc ms system

Manufactured by Agilent Technologies

The Agilent 1200 series LC/MS system is a liquid chromatography-mass spectrometry (LC/MS) instrument designed for analytical applications. It combines high-performance liquid chromatography (HPLC) with mass spectrometry technology to provide separation, identification, and quantification of chemical compounds in a sample. The system features modular components that can be configured to meet specific analytical requirements.

Automatically generated - may contain errors

5 protocols using 1200 series lc ms system

1

Characterization of Bioactive Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Ultraviolet (UV) measurements were taken using a NanoDrop 2000 ultra-micro spectrophotometer. CD spectra were recorded using a JASCO J-815 spectropolarimeter. NMR spectra were determined using a Bruker Avance III 400 NMR spectrometer (1H, 400 MHz, 13C, 100 MHz). Low-resolution electrospray ionization mass spectrometry (ESIMS) data were collected on an Agilent1200 series LC/MS system, and high-resolution ESIMS (HRESIMS) data were acquired on an Agilent 6250TOF LC/MS. Semipreparative HPLC was performed on a Calmflowplus system that was equipped with a 50D UV–vis Detector (Lumiere Tech Ltd) and a YMC Pack ODS-A column (10 mm × 250 mm 5 μm, Japan). Silica gel (200–300 mesh, Qingdao Marine Chemical Factory, Qingdao, China), ODS (YMC, Japan), and Sephadex LH-20 (GE Healthcare BioSciences AB, Sweden) were used as packing materials for column chromatography. All chemicals used in the study were of analytical grade.
+ Open protocol
+ Expand
2

Time-course Monitoring of Ampicillin Reactions

Check if the same lab product or an alternative is used in the 5 most similar protocols
The ampicillin sodium salt (150 mg, 0.4 mmol) and the carbonyl compound (8.6 mmol) were dissolved in H2O (30 mL) and the solution was acidified to pH 2. The solution was then aliquoted into three microwave reaction vessels (10 mL per vessel). Each vessel was then heated in heating block at 100 °C with stirring. Samples were taken and immediately frozen on dry ice after 0 min (before heating) and after 15 minutes, 30 minutes, 45 minutes, 60 minutes, 75 minutes, 90 minutes, 105 minutes, 2 hours, 2.5 hours, 3 hours, 4 hours, and 5 hours heating. The samples were then analysed by LC/MS using an Agilent Technologies 1200 series LC/MS system with an H2O/MeCN solvent system (if a precipitate formed during the reaction, the samples were diluted 1:1 with acetonitrile (MeCN) to dissolve the precipitate before analysis). MS signal intensities for each product were extracted from the spectra and were calibrated using purified controls (products 1-5). A control time-course without added carbonyl was also conducted, which revealed formation of 2.
+ Open protocol
+ Expand
3

Solid-Phase Peptide Synthesis and Purification

Check if the same lab product or an alternative is used in the 5 most similar protocols
All peptides were synthesized using standard solid-phase peptide synthesis in an automated microwave-assisted peptide synthesizer (CEM Liberty 1) using Fmoc-protected amino acids. Peptide cleavage was performed using a cleavage cocktail containing 7.6 mL trifluoroacetic acid (TFA), 0.2 mL triisopropylsilane (TIS), 400 mg phenol, and 0.2 mL double distilled water. The peptides were cleaved from the resin for ~3 h at room temperature and precipitated in cold ethyl ether. The cleaved peptides were dried in vacuo and purified by reverse phase HPLC (PerkinElmer Flexar system) using 95%/5% (v/v) water/acetonitrile with trace (0.1vol.%) of TFA as the starting solvent mobile phase. A linear gradient of acetonitrile was used to separate the products through a semi-prep scale peptide C18 column at 5 mL/min flow rate. The separation processes were monitored with a UV/vis detector at 280 nm (for peptides with tyrosine residue) or 220 nm (for peptides without tyrosine residue). Purified peptides were characterized with liquid chromatography coupled with mass spectrometry (Agilent Technologies, 1200 series LC/MS system).
+ Open protocol
+ Expand
4

Purification and Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All materials were obtained from commercial suppliers and used without purification, unless otherwise noted. Dry organic solvents, packaged under nitrogen in septum-sealed bottles, were purchased from EMD Millipore and Sigma-Aldrich Co. Reactions were monitored using EMD silica gel 60 F254 TLC plates or using an Agilent 1200 series LCMS system with a diode array detector and an Agilent 6120 quadrupole MS detector. Compound purification was accomplished by liquid chromatography on a Teledyne Isco CombiFlash RF+ flash chromatography system. Nuclear magnetic resonance (NMR) spectra were recorded on an Agilent NMR spectrometer (400 MHz) at room temperature. Chemical shifts are reported in ppm relative to residual solvent signal. The residual shifts were taken as internal references and reported in ppm.
+ Open protocol
+ Expand
5

Spectroscopic Characterization of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
CD spectra were determined on a JASCO J-810 spectropolarimeter (JASCO Corporation), and UV data were recorded using a PERSEE UV-VIS spectrophotometer T9 (Beijing, China). NMR experiments were carried out on a Bruker AVANCE III 400 NMR spectrometer (Bruker, Germany), using tetramethylsilane (TMS) or solvent signals as an internal reference. HRESIMS data were collected on an Agilent 6250 TOF LC/MS, and ESIMS data were acquired on an Agilent 1200 series LC/MS system. Semipreparative HPLC was run on a Calmflowplus system that was equipped with a YMC Pack ODS-A column (10 mm × 250 mm 5 μm, Japan) and a 50D UV-vis Detector (Lumiere Tech Ltd) and with a flow rate of 2.0 ml/min. Packing materials for column chromatography were silica gel (200–300 mesh; Qingdao Marine Chemical Factory, Qingdao, China), ODS (YMC, Japan), and Sephadex LH-20 (GE Healthcare BioSciences AB, Sweden). All chemicals used in the study were of analytical grade.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!