Agilent 1260 hplc 6520 qtof ms instrument

Manufactured by Agilent Technologies
Sourced in United States

The Agilent 1260 HPLC/6520 QTOF-MS instrument is a high-performance liquid chromatography (HPLC) system coupled with a quadrupole time-of-flight mass spectrometry (QTOF-MS) detector. It provides accurate mass measurement and high-resolution capabilities for qualitative and quantitative analysis of a wide range of compounds.

Automatically generated - may contain errors

4 protocols using agilent 1260 hplc 6520 qtof ms instrument

1

HPLC and LC-MS for Chemical Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
HPLC analyses were carried out with an Apollo C18 column (5 μm, 4.6 mm × 250 mm, Alltech, Deerfield, IL, USA) on a Shimadzu HPLC system (Shimadzu, Kyoto, Japan). Briefly, the column was developed with solution A (water with 0.1% trifluoroacetic acid) and acetonitrile at a flow rate of 0.8 mL/min. The percentage of acetonitrile was changed using the following gradient: 0–5 min, 10%; 5–25 min, 10%–90%; 25–30 min, 90%–100%; 30–35 min, 100%. The detection wavelength was 320 nm. LC-MS analyses were performed on an Agilent 1260/6460 Triple-Quadrupole LC/MS system (Santa Clara, CA, USA) with an electrospray ionization source. HR-ESI-MS was performed on an Agilent 1260 HPLC/6520 QTOF-MS instrument (Santa Clara, CA, USA). NMR spectra were recorded at room temperature on a Bruker-500 NMR spectrometer (Billerica, MA, USA).
+ Open protocol
+ Expand
2

Analytical HPLC Characterization of Rare Sugars

Check if the same lab product or an alternative is used in the 5 most similar protocols
Analytical HPLC was performed with a Dionex CarboPac™ PA1 BioLC™ column (4 × 250 mm, Thermo Fisher Scientific, USA) on a Shimadzu HPLC system (Shimadzu, Japan). For the detections of ADP-d,d-manno-heptose and ADP-β-d-mannose, the column was developed with solvent A (ddH2O) and solvent B (1.0 M CH3COONH4) at a flow rate of 1.0 mL/min. The percentage of solvent B was changed using the following gradient: 0–5 min, 15%; 5–30 min, 15%–45%; 30–32 min, 45%–90%; 32–38 min, 90%; 38–40 min, 90%–15%; and 40–45 min, 15%. To detect ADP-l,d-manno-heptose, the percentage of solvent B was changed using the following gradient:0–5 min, 24%; 5–30 min, 24%–27%; 30–32 min, 27%–90%; 32–38 min, 90%; 38–40 min, 90%–24%; and 40–45 min, 24%. To detect ADP-d-glycero-β-d-altro-heptose, the percentage of solvent B was changed using the following gradient: 0–5 min, 15%; 5–30 min, 15%–30%; 30–40 min, 30%–45%; 40–42 min, 45%–90%; 42–52 min, 90%; and 52–53 min, 90%–15%; and 53–63 min, 15%. The detection wavelength was set as 254 nm.
HRMS was performed on an Agilent 1260 HPLC/6520 QTOF-MS instrument with an electrospray ionization source. NMR spectra were recorded at room temperature on a Bruker-500 NMR.
+ Open protocol
+ Expand
3

Analytical Instrumentation for Metabolomics

Check if the same lab product or an alternative is used in the 5 most similar protocols
A direct heat CO2 incubator (Forma™ 311), Varioskan® Flash Microplate Multimode Readers, and NanoDrop One UV-Vis spectrophotometer were purchased from Thermo Fisher Scientific (Waltham, MA, USA). A LightCycler PCP was purchased from Roche (CA, USA). A Centrifuge 5417R was obtained from Eppendorf (Hamburg, Germany). Agilent 1260 HPLC/6520 QTOF-MS instrument, Eclipse Plus C18 chromatography column, and Cary Eclipse fluorescence spectrophotometer were obtained from Agilent Technologies, Inc. (Agilent, Milford, MA, USA). Ultra-High-Performance Liquid Chromatography System and ACQUITY UPLC HSS C18 column (100 × 2.1 mm, 1.7 μm) were from Waters (Milford, MA, USA). The X500 QTOF Mass spectrometer system was purchased from AB Sciex Pte. Ltd. (MA, USA).
+ Open protocol
+ Expand
4

HPLC-MS Analysis of AFN Congeners

Check if the same lab product or an alternative is used in the 5 most similar protocols
HPLC detection of AFN congeners was performed on a Shimadzu HPLC system (Shimadzu, Kyoto, Japan) by an Apollo C18 column (5 μm, 4.6 mm × 250 mm, Alltech, Deerfield, IL, United States). The Apollo C18 column was eluted with acetonitrile and water containing 0.1% trifluoroacetic acid at a flow rate of 1.0 mL/min. Percentage of acetonitrile was changed linearly from 15 to 50% in 5 min, from 50 to 87% in 25 min, 87% for 5 min, and from 87 to 100% in 5 min. The detection wavelength was 220 nm. LC-MS analyses were performed on an Agilent 1260/6460 Triple-Quadrupole LC/MS system (Santa Clara, CA, United States) with an electrospray ionization source. HR-ESI-MS was performed on an Agilent 1260 HPLC/6520 QTOF-MS instrument (Santa Clara, CA, United States). NMR spectra were recorded at room temperature on a Bruker-500 NMR spectrometer (Billerica, MA, United States).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!