The largest database of trusted experimental protocols

Masshunter software version 4.4

Manufactured by Agilent Technologies

MassHunter software (version 4.4) is a data analysis software developed by Agilent Technologies for use with Agilent mass spectrometry instruments. The software's core function is to process and analyze mass spectrometry data.

Automatically generated - may contain errors

2 protocols using masshunter software version 4.4

1

Trace Element Analysis by ICP-MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
Trace element analyses was performed on an Agilent 7900 quadrupole Inductively Coupled Plasma-Mass Spectrometer (ICP-MS) equipped with a High Matrix Introduction system and Agilent Mass
Hunter software (version 4.4) for instrument control and data processing (Agilent Technologies 2009). Detailed parameters for method quantification, adjustments and validation are outlined in (Webster et al. 2021, under review) and in (Webster et al. 2021a ) for analysis of environmental samples. In brief, Argon as the dilution gas was added before sample introduction into the plasmas.
Helium collision cell mode using the 4 th generation Octopole Reaction System was used for analysis of element isotopes 11 B, 55 Mn, 56 Fe, 59 Co, 60 Ni, 63 Cu, 66 Zn, 95 Mo. Inter-element corrections were made for possible isobaric interferences of high 115 Sn on 115 In used as internal standard. Hydrogen reaction gas was used to measure 78 Se to improve sensitivity and remove the dual-charged interference from 156 Gd observed in some samples during initial investigation. Optimization for sensitivity and low oxide ratios (CeO/Ce < 0.3%) was performed daily.
+ Open protocol
+ Expand
2

Trace Element Analysis by ICP-MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
Trace element analyses was performed on an Agilent 7900 quadrupole Inductively Coupled Plasma-Mass Spectrometer (ICP-MS) equipped with a High Matrix Introduction system and Agilent Mass Hunter software (version 4.4) for instrument control and data processing (Agilent Technologies 2009) . Detailed parameters for quantification, adjustments and validation are outlined in Webster et al. (under review) . In brief, Argon as the dilution gas was added before sample introduction into the plasmas. Helium collision cell mode using the 4 th generation Octopole Reaction System was used for analysis of element isotopes 11 B, 27 Al, 51 V, 52 Cr, 55 Mn, 56 Fe, 59 Co, 60 Ni, 63 Cu, 66 Zn, 75 As, 88 Sr, 95 Mo, 111 Cd, 118 Sn, 121 Sb, 137 Ba, 202 Hg and 208 Pb. Inter-element corrections were made for possible isobaric interferences of high 115 Sn on 115 In used as internal standard. Lead was expressed as the sum of isotope masses 206, 207 and 208. Hydrogen reaction gas was used to measure 78 Se to improve sensitivity and remove the dual-charged interference from 156 Gd observed in some samples during initial investigation. Optimization for sensitivity and low oxide ratios (CeO/Ce < 0.3%) was performed daily.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists